An analysis of dislocation of the domed Oxford Lateral Unicompartmental Knee Replacement

被引:10
|
作者
Weston-Simons, J. S. [1 ]
Kendrick, B. J. L. [1 ]
Mentink, M. J. A. [1 ]
Pandit, H. [1 ]
Gill, H. S. [2 ]
Murray, D. W. [1 ]
机构
[1] Nuffield Orthopaed Ctr, Nuffield Dept Orthopaed Rheumatol & Musculoskelet, Oxford OX3 7LD, England
[2] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
来源
KNEE | 2014年 / 21卷 / 01期
关键词
Dislocation; Domed bearing; Unicompartmental knee replacement; Component positioning; BEARING; MRI;
D O I
10.1016/j.knee.2013.04.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Oxford Unicompartmental Knee Replacement (OUKR) uses a mobile bearing to minimise wear. Bearing dislocation is a problem in the lateral compartment as the ligaments are loose in flexion. A domed tibial component has been introduced to minimise the risk of dislocation, yet they still occur, particularly medially. The aim of this mechanical study was to compare the domed and flat tibial components and to identify surgical factors that influence the risk of dislocation. Method: A jig was constructed to assess the amount of vertical distraction of the lateral OUKR for a dislocation to occur. Three methods of dislocation were assessed: laterally, medially, 'over the wall' and anteriorly. The study focused on medial dislocation. Results: Significantly (p = 0.02) greater vertical distraction was required to dislocate the bearing with the domed tibia rather than the flat. For medial dislocation bearing distance from the wall, femoral component external rotation and tibial rotation were associated with significantly less distraction for dislocation. With the optimal technique with the domed tibia the distraction required to dislocate the bearing medially was 6.4 mm, whereas with poor technique it was 4.6 mm. Conclusions: This study suggests that to minimise the risk of dislocation the domed tibia should be used. The component should be implanted so the bearing is close to the wall, but does not hit it, and in flexion the femoral and tibial components should be neutrally aligned. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:304 / 309
页数:6
相关论文
共 50 条
  • [41] Unicompartmental knee replacement
    Newman, JH
    KNEE, 2000, 7 (02): : 63 - 70
  • [42] Fixed lateral unicompartmental knee replacement is a reliable treatment for lateral compartment osteoarthritis after mobile-bearing medial unicompartmental replacement
    Lazzara, Joseph T.
    Arthur, Lachlan W.
    Jenkins, Cathy
    Dodd, Christopher A. F.
    Mellon, Stephen J.
    Murray, David W.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (12) : 5407 - 5412
  • [43] Fixed lateral unicompartmental knee replacement is a reliable treatment for lateral compartment osteoarthritis after mobile-bearing medial unicompartmental replacement
    Joseph T. Lazzara
    Lachlan W. Arthur
    Cathy Jenkins
    Christopher A. F. Dodd
    Stephen J. Mellon
    David W. Murray
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 5407 - 5412
  • [44] The influence of surgical factors on dislocation of the meniscal bearing after Oxford medial unicompartmental knee replacement A CASE-CONTROL STUDY
    Lee, S. Y.
    Bae, J. H.
    Kim, J. G.
    Jang, K. M.
    Shon, W. Y.
    Kim, K. W.
    Lim, H. C.
    BONE & JOINT JOURNAL, 2014, 96B (07): : 914 - 922
  • [45] Bearing Separation From the Lateral Wall of the Tibial Component Is a Risk of Anterior Dislocation of the Mobile Bearing in Oxford Unicompartmental Knee Arthroplasty
    Hiranaka, Takafumi
    Suda, Yoshihito
    Kamenaga, Tomoyuki
    Fujishiro, Takaaki
    Koide, Motoki
    Saitoh, Akira
    Tanaka, Atsuki
    Arimoto, Akihiko
    Okamoto, Koji
    JOURNAL OF ARTHROPLASTY, 2022, 37 (05): : 942 - 947
  • [46] Early results of a domed tibia, mobile bearing lateral unicompartmental knee arthroplasty from an independent centre
    Altuntas, Altay O.
    Alsop, Helen
    Cobb, Justin P.
    KNEE, 2013, 20 (06): : 466 - 470
  • [47] The Oxford medial unicompartmental knee replacement using a minimally-invasive approach
    Pandit, H
    Jenkins, C
    Barker, K
    Dodd, CAF
    Murray, DW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (01): : 54 - 60
  • [48] Cementless fixation in Oxford unicompartmental knee replacement A MULTICENTRE STUDY OF 1000 KNEES
    Liddle, A. D.
    Pandit, H.
    O'Brien, S.
    Doran, E.
    Penny, I. D.
    Hooper, G. J.
    Burn, P. J.
    Dodd, C. A. F.
    Beverland, D. E.
    Maxwell, A. R.
    Murray, D. W.
    BONE & JOINT JOURNAL, 2013, 95B (02): : 181 - 187
  • [49] The Oxford medial unicompartmental knee replacement using a minimally-invasive approach
    Saweeres, E. S. B.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (08): : 1116 - 1117
  • [50] Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year
    Pandit, H.
    Jenkins, C.
    Beard, D. J.
    Gallagher, J.
    Price, A. J.
    Dodd, C. A. F.
    Goodfellow, J. W.
    Murray, D. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (02): : 185 - 189