Association between tissue characteristics evaluated with optical coherence tomography and mid-term results after paclitaxel-coated balloon dilatation for in-stent restenosis lesions: a comparison with plain old balloon angioplasty

被引:20
|
作者
Tada, Takeshi [1 ]
Kadota, Kazushige [1 ]
Hosogi, Shingo [2 ]
Miyake, Koshi [1 ]
Amano, Hideo [1 ]
Nakamura, Michitaka [1 ]
Izawa, Yu [1 ]
Kubo, Shunsuke [1 ]
Ichinohe, Tahei [1 ]
Hyoudou, Yusuke [1 ]
Eguchi, Haruki [1 ]
Hayakawa, Yuki [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Shigemoto, Yoshikazu [1 ]
Habara, Seiji [1 ]
Tanaka, Hiroyuki [1 ]
Fuku, Yasushi [1 ]
Kato, Harumi [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Med, 1-1-1 Miwa, Kurashiki, Okayama 7108602, Japan
[2] Kochi Hlth Sci Ctr, Dept Cardiovasc Med, Kochi, Japan
关键词
optical coherence tomography; in-stent restenosis lesion; paclitaxel-coated balloon; IMPLANTATION; VISUALIZATION; PATTERNS;
D O I
10.1093/ehjci/jet165
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Morphological assessment of neointimal tissue using optical coherence tomography (OCT) is important for clarifying the pathophysiology of in-stent restenosis (ISR) lesions. The aim of this study was to determine the impact of OCT findings on recurrence of ISR after paclitaxel-coated balloon (PCB) dilatation compared with plain old balloon angioplasty (POBA). Between July 2008 and May 2012, we performed percutaneous coronary intervention for 214 ISR lesions using POBA PCB (146 lesions, PCB group) or POBA only (68 lesions, POBA group). Morphological assessment of neointimal tissue using OCT, including assessment of restenotic tissue structure and restenotic tissue backscatter, was performed. We examined the association between lesion morphologies and mid-term (68 months) results including ISR and target lesion revascularization (TLR) rates. Both ISR and TLR rates of lesions with a homogeneous structure were significantly lower in the PCB group than those in the POBA group (ISR: 20.0 vs. 55.6, P 0.002, TLR: 12.7 vs. 37.0, P 0.019), but there was no difference between the two groups in ISR and TLR rates of lesions with a heterogeneous or layered structure. Both ISR and TLR rates of lesions with high backscatter were significantly lower in the PCB group than those in the POBA group (ISR: 19.8 vs. 52.5, P 0.001, TLR: 13.6 vs. 42.5, P 0.001), but there was no difference between the two groups in ISR and TLR rates of lesions with low backscatter. Morphological assessment of ISR tissue using OCT might be useful for identifying ISR lesions favourable for PCB dilatation.
引用
下载
收藏
页码:307 / 315
页数:9
相关论文
共 50 条
  • [1] Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation
    Tada, Takeshi
    Kadota, Kazushige
    Hosogi, Shingo
    Miyake, Koshi
    Ohya, Masanobu
    Amano, Hideo
    Izawa, Yu
    Kanazawa, Takenori
    Kubo, Shunsuke
    Ichinohe, Tahei
    Hyoudou, Yusuke
    Hayakawa, Yuki
    Sabbah, Mahmoud Mohamed Hassan
    Otsuru, Suguru
    Hasegawa, Daiji
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Katoh, Harumi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (10) : 1101 - 1111
  • [2] Impact of neoatherosclerosis in lesions with in-stent restenosis evaluated by optical coherence tomography on mid-term outcome after plain old balloon angioplasty and drug coated balloon
    Nakamura, D.
    Nishino, M.
    Yasunaga, M.
    Yanagawa, K.
    Nakamura, H.
    Matsuhiro, Y.
    Yasumura, K.
    Yasumoto, K.
    Tanaka, A.
    Mori, N.
    Yano, M.
    Egami, Y.
    Shutta, R.
    Tanouchi, J.
    EUROPEAN HEART JOURNAL, 2017, 38 : 648 - 648
  • [3] Tissue morphology of in-stent ree-restenosis lesions after paclitaxel-coated balloon dilatation and plain old balloon angioplasty for in-stent restenosis lesions: impact of previously implanted stent
    Tada, T.
    Kadota, K.
    Habara, S.
    Tanaka, H.
    Fuku, Y.
    Goto, T.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2014, 35 : 805 - 805
  • [4] The association between tissue morphology assessed with optical coherence tomography and mid-term results after paclitaxel-coated balloon dilatation
    Tada, T.
    Kadota, K.
    Habara, S.
    Tanaka, H.
    Fuku, Y.
    Goto, T.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1146 - 1146
  • [5] The Association Between Tissue Morphology Assessed With Optical Coherence Tomography and Mid-term Results After Paclitaxel-coated Balloon Dilatation
    Tada, Takeshi
    Kadota, Kazushige
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    CIRCULATION, 2014, 130
  • [6] The Association Between Tissue Characteristics assessed with Optical Coherence Tomography and Midterm Results After Percutaneous Coronary Intervention for In-stent Restenosis Lesions: A Comparison between Balloon Angioplasty, Paclitaxel-coated Balloon Dilatation, and Drug-eluting Stent Implantation
    Tada, Takeshi
    Kadota, Kazushige
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Mitsudo, Kazuaki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B22 - B23
  • [7] Comparison of mid-term restenosis rate between normal balloon and paclitaxel eluting balloon angioplasty for in-stent restenosis according to the tissue assessment by optical coherence tomography
    Hosogi, S.
    Shimizu, H.
    Habara, S.
    Tada, T.
    Tanaka, H.
    Fuku, Y.
    Goto, T.
    Kadota, K.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 491 - 491
  • [8] Comparison of the efficacy of balloon angioplasty or paclitaxel-coated balloon or stent implantation for in-stent restenosis based on analysis by optical coherence tomography
    Yamane, K.
    Hayashi, Y.
    Fujii, Y.
    Ueda, Y.
    Morita, Y.
    Miyake, Y.
    Fujiwara, M.
    Nagamoto, Y.
    Mito, S.
    Watari, Y.
    Tamekiyo, H.
    Okimoto, T.
    Muraoka, Y.
    EUROPEAN HEART JOURNAL, 2018, 39 : 528 - 528
  • [9] Long-term Outcomes of Repeated Paclitaxel-coated Balloon Angioplasty for Recurrent Restenosis Lesions after Paclitaxel-coated Balloon Angioplasty for In-stent Restenosis
    Iwasaki, Keiichiro
    Kadota, Kazushige
    Kuwayama, Akimune
    Miura, Katsuya
    Ohya, Masanobu
    Shimada, Takenobu
    Kubo, Shunsuke
    Hyodo, Yusuke
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B159 - B160
  • [10] Neoatherosclerosis After Paclitaxel-Coated Balloon Angioplasty for In-Stent Restenosis
    Alfonso, Fernando
    Jimenez-Quevedo, Pilar
    Gonzalo, Nieves
    Medina, Miguel
    Banuelos, Camino
    CIRCULATION, 2014, 129 (08) : 923 - 925