Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode

被引:58
|
作者
Shi, Haibin
Yang, Yu
Huang, Jiadong
Zhao, Zixia
Xu, Xinhua
Anzai, Jun-ichi
Osa, Tetsuo
Chen, Qiang [1 ]
机构
[1] Nankai Univ, Coll Life Sci, Tianjin 300071, Peoples R China
[2] Tianjin Univ, Sch Mat Sci & Engn, Tianjin 300072, Peoples R China
[3] Tohoku Univ, Grad Sch Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808578, Japan
基金
中国国家自然科学基金;
关键词
choline oxidase; amperometric biosensor; layer-by-layer; Prussian blue; 6-O-ethoxytrimethylammoniochitosan chloride;
D O I
10.1016/j.talanta.2006.02.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric choline biosensor was developed by immobilizing choline oxidase (ChOx) in a layer-by-layer (LBL) multilayer film on a platinum (Pt) electrode modified with Prussian blue (PB). 6-O-Ethoxytrimethylammoniochitosan chloride (EACC) was used to prepare the ChOx LBL films. The choline biosensor was used at 0.0 V versus Ag/AgCl to detect choline and exhibited good characteristics such as relative low detection limit (5 x 10(-7) M), short response time (within 10 s), high sensitivity (88.6 mu A mM(-1) cm(-2)) and a good selectivity. The results were explained based on the ultrathin nature of the LBL films and the low operating potential that could be due to the efficient catalytic reduction of H2O2 by PB. In addition, the effects of pH, temperature and applied potential on the amperometric response of choline biosensor were evaluated. The apparent Michaelis-Menten constant was found to be (0.083 +/- 0.001) x 10(-3) M. The biosensor showed excellent long-term storage stability, which originates from a strong adsorption of ChOx in the EACC multilayer film. When the present choline biosensor was applied to the analysis of phosphatidylcholine in serum samples, the measurement values agreed satisfactorily with those by a hospital method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:852 / 858
页数:7
相关论文
共 50 条
  • [31] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    TENG YuanJie
    Research Center of Analysis Test
    Science China(Chemistry), 2010, (12) : 2581 - 2586
  • [32] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    Teng YuanJie
    Chen Chen
    Zhou ChangXiang
    Zhao HongLi
    Lan MinBo
    SCIENCE CHINA-CHEMISTRY, 2010, 53 (12) : 2581 - 2586
  • [33] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    YuanJie Teng
    Chen Chen
    ChangXiang Zhou
    HongLi Zhao
    MinBo Lan
    Science China Chemistry, 2010, 53 : 2581 - 2586
  • [34] Amperometric DNA sensor using gold electrode modified with polymerized mediator by layer-by-layer adsorption
    Suye, S
    Matsuura, T
    Kimura, T
    Zheng, H
    Hori, T
    Amano, Y
    Katayama, H
    MICROELECTRONIC ENGINEERING, 2005, 81 (2-4) : 441 - 447
  • [35] Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes
    Garjonyte, R
    Malinauskas, A
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10): : 445 - 451
  • [36] An amperometric cholesterol biosensor based on cholesterol oxidase immobilized in polypyrrole on a Prussian blue modified electrode
    Li, JP
    Peng, TZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 669 - 673
  • [37] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [38] Layer-by-Layer AuNPs-SiPy+/Prussian blue nanoparticles modified electrodes: characterization and electrocatalytic effects
    Calaca, Giselle Nathaly
    Erdmann, Cristiane Andreia
    Soares, Ana Leticia
    Pessoa, Christiana Andrade
    Fujiwara, Sergio Toshio
    Garcia, Jarem Raul
    Vidotti, Marcio
    Wohnrath, Karen
    ELECTROCHIMICA ACTA, 2017, 249 : 104 - 112
  • [39] Electrochemical Sensor to Detect Proteinuria Using Peptidases and Glutamate Oxidase Jointly Immobilized on a Prussian Blue-modified Electrode
    Ito, Kentaro
    Inoue, Kumi Y.
    Miura, Tsubasa
    Matsue, Tomokazu
    Shiku, Hitoshi
    ELECTROCHEMISTRY, 2021, 89 (05) : 409 - 414
  • [40] Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yin, Feng
    Li, Jing
    Zhao, Zi-Xia
    Huang, Jia-Dong
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06): : 838 - 844