Tc-99m sulfur colloid and Tc-99m tagged red blood cell methods are comparable for detecting lower gastrointestinal bleeding in clinical practice

被引:24
|
作者
Ponzo, F [1 ]
Zhuang, HM [1 ]
Liu, FM [1 ]
Lacorte, LB [1 ]
Moussavian, B [1 ]
Wang, S [1 ]
Alavi, A [1 ]
机构
[1] Hosp Univ Penn, Div Nucl Med, Dept Radiol, Philadelphia, PA 19104 USA
关键词
D O I
10.1097/00003072-200206000-00003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The objective of this study was to determine whether the Tc-99m red blood cells (Tc-99m RBC) method has a true advantage over the Tc-99m sulfur colloid (Tc-99m SC) technique in a busy clinical practice for detecting and localizing lower gastrointestinal bleeding sites. Methods: Three hundred fifty-nine consecutive gastrointestinal bleeding studies performed during the past 4 years were reviewed retrospectively. One hundred ninety-three scans were obtained with Tc-99m SC (scan duration, 30 minutes) and 138 studies were performed after the administration of Tc-99m RBC (scan duration, I hour). In addition, 28 examinations with Tc-99m SC were followed immediately by Tc-99m RBC scans for a duration of several hours. The results of the two methods were analyzed and the performance of the two techniques was compared. Results: Among 193 scans performed using the Tc-99m SC method, 47 (24.4%) successfully identified the location of the bleeding site, whereas in 138 scans performed using Tc-99m RBC, 38 (27.5%) were successful for this purpose. In the remaining 28 scans in which the Tc-99m SC scan was followed by the Tc-99m RBC study, only 4 (14.3%) positive bleeding sites were identified after a prolonged imaging period. Discussion:The theoretical advantages of the Tc-99m RBC technique compared with the Tc-99m SC method cannot be substantiated by this study. Our findings suggest that the efficacy of these two methods is nearly equal at a practical level. Conclusion: The simpler and cost-effective Tc-99m SC method is as efficient as the Tc-99m RBC method when the scanning time is limited to I hour and optimal imaging and interpretation schemes are used.
引用
收藏
页码:405 / 409
页数:5
相关论文
共 50 条
  • [41] TC-99M (TC-99M) MERCAPTOACETYLTRIGLYCINE - UPDATE ON THE NEW TC-99M RENAL TUBULAR FUNCTION AGENT
    ESHIMA, D
    TAYLOR, A
    SEMINARS IN NUCLEAR MEDICINE, 1992, 22 (02) : 61 - 73
  • [42] Incidental detection of a bleeding gastrointestinal stromal tumor on Tc-99m red blood cell scintigraphy
    Santhosh, Sampath
    Bhattacharya, Anish
    Gupta, Vikas
    Singh, Rajinder
    Radotra, Bishan Dass
    Mittal, Bhagwant Rai
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2012, 27 (04): : 269 - 271
  • [43] PREPARATION AND EVALUATION OF TC-99M HYDROXYETHYL STARCH AS A POTENTIAL RADIOPHARMACEUTICAL FOR LYMPHOSCINTIGRAPHY - COMPARISON WITH TC-99M HUMAN SERUM-ALBUMIN, TC-99M DEXTRAN, AND TC-99M SULFUR MICROCOLLOID
    SADEK, S
    OWUNWANNE, A
    ABDELDAYEM, HM
    YACOUB, T
    LYMPHOLOGY, 1989, 22 (04) : 157 - 166
  • [44] In-vitro adsorption of Tc-99m MIBI, Tc-99m tetrofosmin, Tc-99m furifosmin and Tc-99m O4- onto tubes
    Rodrigues, M
    Chehne, F
    Sinzinger, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1262 - 1262
  • [45] RAPID ASSAY OF UNBOUND TC-99M) IN PREPARATIONS OF TC-99M) LABELED RED BLOOD-CELLS
    MCLEAN, JRN
    ROCKWELL, LJ
    BRITISH JOURNAL OF RADIOLOGY, 1977, 50 (597): : 663 - 664
  • [46] PATIENTS WITH HEMOPTYSIS EXAMINED BY TC-99M SULFUR COLLOID AND TC-99M-LABELED RED-BLOOD-CELLS - A PRELIMINARY APPRAISAL
    WINZELBERG, GG
    WHOLEY, MH
    JARMOLOWSKI, CA
    SACHS, M
    WEINBERG, JH
    RADIOLOGY, 1984, 153 (02) : 523 - 526
  • [47] COMPARISON AS A LYMPHOSCINTIGRAPHIC AGENT BETWEEN TC-99M DEXTRAN AND TC-99M ANTIMONY SULFIDE COLLOID
    JUMA, N
    ANDREY, T
    EGE, GN
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (688): : 325 - 330
  • [48] Meckel's diverticulum findings on Tc-99m red blood cell scintigraphy in a bleeding leukemic patient confirmed by Tc-99m pertechnetate scintigraphy
    Ciccoritti, L.
    Valenza, V.
    Pierconti, F.
    Di Giuda, D.
    D'Errico, G.
    Antinori, A.
    Crucitti, A.
    CLINICAL NUCLEAR MEDICINE, 2007, 32 (08) : 668 - 670
  • [49] TC-99M SULFUR COLLOID SCANNING IN BLUNT TRAUMA - DETECTION OF ABDOMINAL BLEEDING
    BRONFMAN, HJ
    KUNKEL, BK
    RABIN, HS
    JOURNAL OF NUCLEAR MEDICINE, 1981, 22 (11) : 978 - 980
  • [50] A QUANTITATIVE COMPARISON OF THE BONE IMAGING AGENTS TC-99M DPD, TC-99M HDP AND TC-99M MDP
    BERGQVIST, L
    DARTE, L
    NAVERSTEN, Y
    PALMER, J
    BRISMAR, J
    CEDERQVIST, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1983, 8 (05): : A23 - A23