Surrogate analyte approach for quantitation of endogenous NAD+ in human acidified blood samples using liquid chromatography coupled with electrospray ionization tandem mass spectrometry

被引:17
|
作者
Liu, Liling [1 ]
Cui, Zhiyi [1 ]
Deng, Yuzhong [1 ]
Dean, Brian [1 ]
Hop, Cornelis E. C. A. [1 ]
Liang, Xiaorong [1 ]
机构
[1] Genentech Inc, Drug Metab & Pharmacokinet, San Francisco, CA 94080 USA
关键词
LC-MS; Surrogate analyte; Human blood; NAD(+); Baseline level; Circadian effect; NICOTINAMIDE ADENINE-DINUCLEOTIDE; SACCHAROMYCES-CEREVISIAE; CALORIE RESTRICTION; HUMAN PLASMA; LC-MS/MS; MATRIX; QUANTIFICATION; NUCLEOTIDES; VALIDATION; ACID;
D O I
10.1016/j.jchromb.2015.12.040
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the quantitative determination of NAD(+) in human whole blood using a surrogate analyte approach was developed and validated. Human whole blood was acidified using 0.5 N perchloric acid at a ratio of 1:3 (v:v, blood:perchloric acid) during sample collection. 25 mu L of acidified blood was extracted using a protein precipitation method and the resulting extracts were analyzed using reverse-phase chromatography and positive electrospray ionization mass spectrometry. C-13(5)-NAD(+) was used as the surrogate analyte for authentic analyte, NAD(+). The standard curve ranging from 0.250 to 25.0 mu g/mL in acidified human blood for C-13(5)-NAD(+) was fitted to a 1/chi(2) weighted linear regression model. The LC-MS/MS response between surrogate analyte and authentic analyte at the same concentration was obtained before and after the batch run. This response factor was not applied when determining the NAD(+) concentration from the C-13(5)-NAD(+) standard curve since the percent difference was less than 5%. The precision and accuracy of the LC-MS/MS assay based on the five analytical QC levels were well within the acceptance criteria from both FDA and EMA guidance for bioanalytical method validation. Average extraction recovery of C-13(5)-NAD(+) was 94.6% across the curve range. Matrix factor was 0.99 for both high and low QC indicating minimal ion suppression or enhancement. The validated assay was used to measure the baseline level of NAD(+) in 29 male and 21 female human subjects. This assay was also used to study the circadian effect of endogenous level of NAD(+) in 10 human subjects. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 50 条
  • [31] Determination of Dodine in Fruit Samples by Liquid Chromatography Electrospray Ionization-Tandem Mass Spectrometry
    Le Grand, Rozenn
    Saint-Marcoux, Franck
    Dulaurent, Sylvain
    Sauvage, Francois-Ludovic
    Moesch, Christian
    Lachatre, Gerard
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (01) : 300 - 306
  • [32] Quantitation of paclitaxel and its two major metabolites using a liquid chromatography-electrospray ionization tandem mass spectrometry
    Zhang, Wei
    Dutschman, Ginger E.
    Li, Xin
    Cheng, Yung-Chi
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (22): : 2018 - 2022
  • [33] Determination of flomoxef in human plasma by liquid chromatography/electrospray ionization tandem mass spectrometry
    Kravtsova, Oxana Yu.
    Paramonov, Sergey A.
    Vasilevich, Natalya I.
    Kazyulkin, Denis N.
    Vlasova, Ekaterina
    Engsig, Michael
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) : 1609 - 1614
  • [34] Determination of moxifloxacin in human plasma by liquid chromatography electrospray ionization tandem mass spectrometry
    Vishwanathan, K
    Bartlett, MG
    Stewart, JT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) : 961 - 968
  • [35] Quantitative analysis of acrylamide in tea by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Liu, He
    Zhao, Ganghua
    Yuan, Yuan
    Chen, Fang
    Hu, Xiaosong
    [J]. FOOD CHEMISTRY, 2008, 108 (02) : 760 - 767
  • [36] Analysis of sphingolipids in extracted human plasma using liquid chromatography electrospray ionization tandem mass spectrometry
    Bui, Hai H.
    Leohr, Jennifer K.
    Kuo, Ming-Shang
    [J]. ANALYTICAL BIOCHEMISTRY, 2012, 423 (02) : 187 - 194
  • [37] Determination of 215 pesticide residues in ginger using liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Cao Jing
    Pang Guofang
    Wang Minglin
    Fan Chunlin
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (06) : 579 - 589
  • [38] Analysis of 1-deoxy-sphinginolipids using liquid chromatography coupled to electrospray ionization tandem mass spectrometry
    Park, Hyejung
    Sullards, Mark Cameron
    Merrill, Alfred H.
    Costello, Catherine E.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [39] Determination of bromadiolone in whole blood by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Jin, Mi-Cong
    Ren, Yi-Ping
    Xu, Xiao-Min
    Chen, Xiao-Hong
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2007, 171 (01) : 52 - 56
  • [40] Studies of iridoid glycosides using liquid chromatography/electrospray ionization tandem mass spectrometry
    Ren, Lingling
    Xue, Xingya
    Zhang, Feifang
    Wang, Yongcan
    Liu, Yanfang
    Li, Cunman
    Liang, Xinmiao
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) : 3039 - 3050