Design and Implementation of a Two-Stage Grid-Connected High Efficiency Power Load Emulator

被引:41
|
作者
Kanaan, Hadi Y. [1 ]
Caron, Maxime [2 ]
Al-Haddad, Kamal [2 ]
机构
[1] St Joseph Univ, Fac Engn ESIB, Beirut 11072050, Lebanon
[2] Ecole Technol Super, Dept Genie Elect, Montreal, PQ H3C 1K3, Canada
关键词
Active rectifier; average model; dc-to-ac converter; dc-to-dc converter; dual active bridge ( DAB); harmonic compensation; load emulator; power factor correction; renewable energy; soft switching; DC-DC CONVERTER; MODULATION STRATEGY; BRIDGE;
D O I
10.1109/TPEL.2013.2295023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The need to reduce the time consumption in developing and implementing power converters, and to improve the effectiveness of the test equipment, continues to grow. This trend is further accelerated through the development of electricity-based technology, such as the electric or hybrid vehicle. As the price of energy continues to increase, regenerative test equipment used for validating power converters are gaining importance and attention. This paper focuses on the development of a two-stage regenerative power load emulator. This type of intelligent load requires a connection to the network interface, which, for some applications, should be bidirectional and must possess a galvanic isolation. The development of such grid-connected unit that processes ac-dc conversion is treated in this paper. A 5 kW prototype is used as a base to model, simulate, design, implement, and test such a system. The stability of the interconnection between the two conversion stages is established and tested in real-time applications. The prototype was tested at 180, 220, and 260 V RMS. The measured efficiency is higher than 90%, and the power factor is 0.99 over a wide range of operation.
引用
收藏
页码:3997 / 4006
页数:10
相关论文
共 50 条
  • [41] TRADING MODEL AND PRODUCTION ANALYSIS OF RESIDENTIAL PHOTOVOLTAIC GRID-CONNECTED TWO-STAGE ENERGY
    Yan, Xiuying
    Liu, Pan
    Chang, Juan
    Yan, Xiulian
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (10): : 309 - 316
  • [42] Establishment of a Two-Stage Single Phase Grid-Connected PV System Simulation Model
    Liu, Baozhu
    Wang, Liguo
    Zhang, Yong
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ENERGY, 2013, : 251 - 255
  • [43] Implementation of Grid-Connected Power Conditioner for Renewable Energy
    Zhao, Jianfei
    Jiang, Jianguo
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1165 - 1168
  • [44] Two-Stage Optimization of Battery Energy Storage Capacity to Decrease Wind Power Curtailment in Grid-Connected Wind Farms
    Dui, Xiaowei
    Zhu, Guiping
    Yao, Liangzhong
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (03) : 3296 - 3305
  • [45] Efficiency Analysis of Grid-connected Photovoltaic Power Plants
    Markovic, Milan L. J.
    Ciric, Rade M.
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2017, 3 (03): : 269 - 277
  • [46] Two-Stage PV Inverter System Emulator in Converter Based Power Grid Emulation System
    Cao, Wenchao
    Ma, Yiwei
    Wang, Jingxin
    Yang, Liu
    Wang, Jing
    Wang, Fred
    Tolbert, Leon M.
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 4518 - 4525
  • [47] High-Efficiency Power Conditioning System for Grid-Connected Photovoltaic Modules
    Choi, Woo-Young
    Choi, Jae-Yeon
    JOURNAL OF POWER ELECTRONICS, 2011, 11 (04) : 561 - 567
  • [48] Design and Implementation of a High Step-Up Grid-Connected PV Inverter
    Ma, Tsao-Tsung
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (02): : 416 - 425
  • [49] A High Efficiency and High Linearity Two-stage Power Amplifier
    Wu, Hai-Feng
    Cheng, Qian-Fu
    2015 IEEE INTERNATIONAL WIRELESS SYMPOSIUM (IWS 2015), 2015,
  • [50] Modeling and Stability Analysis of a Single-Phase Two-Stage Grid-Connected Photovoltaic System
    Huang, Liying
    Qiu, Dongyuan
    Xie, Fan
    Chen, Yanfeng
    Zhang, Bo
    ENERGIES, 2017, 10 (12)