Optoelectrokinetically-Enabled Signal Enhancement for a Bead-Based FRET Fluorescence Immunoassay

被引:0
|
作者
Chuang, Han-Sheng [1 ]
Wang, Kuan-Chih [1 ]
Hsieh, Dar-Bin [2 ]
Fu, Yong Qing [3 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan, Taiwan
[2] Natl Cheng Kung Univ, Inst Oral Med, Tainan, Taiwan
[3] Univ West Scotland, Thin Film Ctr, Paisley PA1 2BE, Renfrew, Scotland
关键词
immunoassay; particle; FRET; signal enhancement; optoelectrokinetics; quantum dot Introduction; NUCLEIC-ACIDS; ASSAY; PROTEINS;
D O I
10.1109/ISOT.2014.32
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Bead-based immunoassay has been growing as a promising technology in the point-of-care diagnostics due to great flexibility. For samples with dilute analytes, the colloidal particles can concentrate dispersed analytes and act as carriers for advanced particle manipulation. To realize a rapid in-situ immunoassay, Firster resonance energy transfer (FRET) was used herein to ensure only the target antigen lipocalin 1 (LCN1) to be detected. The measurement was made in an aqueous droplet sandwiched between two parallel electrodes. In addition, an optoelectrokinetic technique was used to further concentrate the functionalized particles to enhance the FRET fluorescent signal. The detection was usually completed within several tens of seconds. A comparison between the based-based diagnostics coupled with the optoelectrokinetic technique and a conventional ELISA reader showed nearly 100-fold improvement of the bio-signal was made. The technique is expected to bring hopes for diagnosing diseases with dilute biomarkers in the early stage.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 50 条
  • [31] Development of a rapid magnetic bead-based immunoassay for sensitive detection of zearalenone
    Zhao, Fengchun
    Shen, Qiang
    Wang, Huimin
    Han, Xiao
    Yang, Zhengyou
    FOOD CONTROL, 2017, 79 : 227 - 233
  • [32] A fast magnetic bead-based colorimetric immunoassay for the detection of tetrodotoxins in shellfish
    Campas, Monica
    Reverte, Jaume
    Rambla-Alegre, Maria
    Campbell, Katrina
    Gerssen, Arjen
    Diogene, Jorge
    FOOD AND CHEMICAL TOXICOLOGY, 2020, 140
  • [33] Optimized magnetic bead-based immunoassay for automated detection of protein toxins
    Deok-Ho Jung
    Kyoungmi Min
    Yongkwon Jeon
    Wonhee Jang
    Youngeun Kwon
    BioChip Journal, 2012, 6 : 293 - 298
  • [34] A HIGHLY SENSITIVE MULTIPLEXED BEAD-BASED IMMUNOASSAY FOR POTENTIAL MALARIA DIAGNOSTICS
    Clor, Julie
    Otto, Mary
    Mcdonald, John
    Jagannathan, Prasanna
    Greenhouse, Bryan
    Kakaru, Abel
    Mulry, James
    Greco, Beatrice
    Tyagarajan, Kamala
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 97 (05): : 490 - 490
  • [35] Magnetic Bead-Based Reverse Colorimetric Immunoassay Strategy for Sensing Biomolecules
    Gao, Zhuangqiang
    Xu, Mingdi
    Hou, Li
    Chen, Guonan
    Tang, Dianping
    ANALYTICAL CHEMISTRY, 2013, 85 (14) : 6945 - 6952
  • [36] Magnetic bead-based chemiluminescent metal immunoassay with a colloidal gold label
    Fan, AP
    Lau, CW
    Lu, JZ
    ANALYTICAL CHEMISTRY, 2005, 77 (10) : 3238 - 3242
  • [37] Development of a Bead-Based Multiplexed Immunoassay Using Image Cytometric Analysis
    Ukita, Yoshiaki
    Kataoka, Chiwa
    Sawadaishi, Kazuyuki
    Yamaguchi, Akinobu
    Utsumi, Yuichi
    SENSORS AND MATERIALS, 2017, 29 (05) : 567 - 573
  • [38] Development of a varicella-zoster virus bead-based immunoassay for serosurveys
    Escudero, Nicole
    Padron-Regalado, Eriko
    El-Badry, Elina
    Matson, Zachary
    Sowers, Sun
    Crooke, Stephen
    JOURNAL OF IMMUNOLOGY, 2024, 212 (01):
  • [39] Rapid Bead-Based Immunoassay for Measurement of Mannose-Binding Lectin
    Bay, J. T.
    Garred, P.
    SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 2009, 69 (06) : 570 - 575
  • [40] A high sensitivity bead-based immunoassay with nanofluidic preconcentration for biomarker detection
    Fan, Yu-Jui
    Deng, Chih-Zong
    Chung, Pei-Shan
    Tian, Wei-Cheng
    Sheen, Horn-Jiunn
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 : 502 - 509