Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

被引:7
|
作者
Iivanainen, Joonas [1 ,2 ]
Borna, Amir [1 ]
Zetter, Rasmus [2 ]
Carter, Tony R. [1 ]
Stephen, Julia M. [3 ]
McKay, Jim [4 ]
Parkkonen, Lauri [2 ]
Taulu, Samu [5 ]
Schwindt, Peter D. D. [1 ]
机构
[1] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[2] Aalto Univ, Sch Sci, Dept Neurosci & Biomed Engn, FI-00076 Aalto, Finland
[3] Mind Res Network, Albuquerque, NM 87106 USA
[4] Candoo Syst Inc, Port Coquitlam, BC V3C 5M2, Canada
[5] Univ Washington, Seattle, WA 98195 USA
基金
欧洲研究理事会; 美国国家卫生研究院;
关键词
calibration; sensor localization; co-registration; optically pumped magnetometer; magnetoencephalography; on-scalp MEG; fluxgate magnetometer; electromagnetic coil; MAGNETOENCEPHALOGRAPHY;
D O I
10.3390/s22083059
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2 degrees, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.
引用
下载
收藏
页数:17
相关论文
共 50 条
  • [41] Measuring the cortical tracking of speech with optically-pumped magnetometers
    de Lange, Paul
    Boto, Elena
    Holmes, Niall
    Hill, Ryan M.
    Bowtell, Richard
    Wens, Vincent
    De Tiege, Xavier
    Brookes, Matthew J.
    Bourguignon, Mathieu
    NEUROIMAGE, 2021, 233
  • [42] Optically Pumped Magnetometers Recent Advances and Applications in Biomagnetism: A Review
    Zhao, Binbin
    Li, Lin
    Zhang, Yaohua
    Tang, Junjian
    Liu, Ying
    Zhai, Yueyang
    IEEE SENSORS JOURNAL, 2023, 23 (17) : 18949 - 18962
  • [43] Feasibility of magnetomyography with optically pumped magnetometers in a mobile magnetic shield
    Nordenstroem, Simon
    Lebedev, Victor
    Hartwig, Stefan
    Kruse, Marlen
    Marquetand, Justus
    Broser, Philip
    Middelmann, Thomas
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [44] Investigations into Vector Light and Its Application in Optically Pumped Magnetometers
    Meng, Xiaoqin
    Tong, Ye
    Xu, Yan
    Chai, Zhen
    Zhongguo Jiguang/Chinese Journal of Lasers, 2024, 51 (18):
  • [45] Differential Measurement With the Balanced Response of Optically Pumped Atomic Magnetometers
    Ichihara, Sunao
    Mizutani, Natsuhiko
    Ito, Yosuke
    Kobayashi, Tetsuo
    IEEE TRANSACTIONS ON MAGNETICS, 2016, 52 (08)
  • [46] Using Optically Pumped Magnetometers to identify initial damage in bulk material during Fatigue Testing
    Thiemann, K.
    Blug, A.
    Koss, P.
    Durmaz, A.
    Laskin, G.
    Bertz, A.
    Kuehnemann, F.
    Straub, T.
    QUANTUM TECHNOLOGIES 2022, 2022, 12133
  • [47] Recording and quantifying fetal magnetocardiography signals using a flexible array of optically-pumped magnetometers
    Escalona-Vargas, Diana
    Bolin, Elijah H.
    Lowery, Curtis L.
    Siegel, Eric R.
    Eswaran, Hari
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (12)
  • [48] Adaptive filter entropy monitoring method for scalar magnetic detection using optically pumped magnetometers
    Qiao, Shuai
    Wang, Qimeng
    Zheng, Doudou
    Hou, Qingfeng
    Zhao, Junzhi
    Tang, Jun
    Yanjun, Li
    Sugawara, Yasuhiro
    Ma, Zongmin
    Liu, Jun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (05)
  • [49] Quantitative 2D Magnetorelaxometry Imaging of Magnetic Nanoparticles Using Optically Pumped Magnetometers
    Jaufenthaler, Aaron
    Schier, Peter
    Middelmann, Thomas
    Liebl, Maik
    Wiekhorst, Frank
    Baumgarten, Daniel
    SENSORS, 2020, 20 (03)
  • [50] Using optically pumped magnetometers to replicate task-related responses in next generation magnetoencephalography
    Safar, Kristina
    Vandewouw, Marlee M.
    Sato, Julie
    Devasagayam, Jasen
    Hill, Ryan M.
    Rea, Molly
    Brookes, Matthew J.
    Taylor, Margot J.
    SCIENTIFIC REPORTS, 2024, 14 (01)