Evaluation of portable X-ray fluorescence (pXRF) in exploration and mining: Phase 1, control reference materials

被引:100
|
作者
Hall, Gwendy E. M.
Bonham-Carter, Graeme F.
Buchar, Angelina
机构
[1] Merrickville, ON, K0G 1N0
[2] Ottawa ON, K1N 6B8
关键词
portable XRF; handheld; benchtop; evaluation; reference materials; accuracy; precision; geochemistry; CONTAMINATED SOILS; SILICATE ROCKS; SOUTH WALES; FIELD; XRF; QUANTIFICATION; CHEMOSTRATIGRAPHY; INSTRUMENTATION; SPECTROMETRY; MINERALOGY;
D O I
10.1144/geochem2013-241
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
This paper describes a project sponsored by the Canadian Mining Industry Research Organisation (CAMIRO) to evaluate the strengths and weaknesses of portable XRF for use in mineral exploration and mining and to develop best-practice protocols in the analysis of rocks, soils, sediments and drill-core. Phase I focussed on the analysis of pulp control reference materials (CRMs) to determine the figures of merit, principally accuracy and precision, of the technique before introducing the confounding parameters associated with in-situ analysis such as heterogeneity, particle size and moisture. Five instruments (three handheld and two portable benchtop) from three manufacturers were used to carry out replicate analyses (n = 10) of a diverse suite of 41 CRMs, from barren granites, through soils and sediments, to ores. Standard factory calibration, in mining and soil modes, was used. The performance of the instruments was evaluated using x-y plots of results versus established element concentrations for the CRMs and the values of goodness of fit (r(2)), slope and intercept documented for both full and restricted concentration ranges. For many elements, the performance across the instruments varied markedly, as did the ability to correct for spectral interferences. Numerous interferences were encountered, particularly from the rare-earth elements (REEs) on transition elements, but also for well-known interference pairs such as Pb on As, Zn on Au, U on Mo, and Th on Bi. In general, major elements with the exception of the light element Mg were well determined, as were Mn and Ti. Sensitivity was inadequate for Cl and P; however, S could be measured with acceptable precision to c. 0.05% S. Performance for the trace elements was categorized as follows: very good for As, Cu, Nb, Pb, Rb, Sr, and Y (r(2)>0.9 for more than 1 instrument); good for Ba, Mo, Sn, Zn and Zr (r(2)>0.9 for 1 instrument); moderate for Cr, Sb, Se, Th and U (r(2) = 0.6-0.8); poor for Ag, Cd, Co, Ni and V; and very poor for Au, Bi, Cs, Hf, Hg, Pd, Sc, Ta, Te and W. Of the REEs determined (La, Ce, Nd, Sm, using the standard calibration by the manufacturer, i.e. not REE-specific), only La showed adequate sensitivity and precision (3-5% RSD), however, only at concentrations approaching c. 1000 ppm (50-100% RSD at La <100 ppm). Slopes of the best-fit lines, where r(2) >= 0.6, ranged from 0.5 to 5.0, indicating that calibration is required by the user for both the soil and mining modes. The precision, shown by 10 replicate readings, was excellent and usually better than 10% RSD except where close to detection limit or where major interferences were present. The beam time study showed that, in most situations, 60 s was a good compromise between productivity and precision but also highlighted cases of significant drift and a lack of improvement in precision with longer beam time. A study of the thin-film sample cover used for cups demonstrated that 4.0-mu m Prolene (R) is superior to the same thickness of Mylar (R) in both transmittance (especially for Mg, Al, Si) and contamination properties.
引用
收藏
页码:99 / 123
页数:25
相关论文
共 50 条
  • [31] A rapid field procedure for screening trace elements in polluted soil using portable X-ray fluorescence (PXRF)
    Martin Peinado, F.
    Morales Ruano, S.
    Bagur Gonzalez, M. G.
    Estepa Molina, C.
    GEODERMA, 2010, 159 (1-2) : 76 - 82
  • [32] Elemental Composition in Female Dry Femora Using Portable X-Ray Fluorescence (pXRF): Association with Age and Osteoporosis
    Zdral, Sofia
    Monge Calleja, Alvaro M.
    Catarino, Lidia
    Curate, Francisco
    Santos, Ana Luisa
    CALCIFIED TISSUE INTERNATIONAL, 2021, 109 (02) : 231 - 240
  • [33] The Application of Portable X-ray Fluorescence (pXRF) for Elemental Analysis of Sediment Samples in the Laboratory and Its Influencing Factors
    Zhou, Shuguang
    Wang, Jinlin
    Bai, Yong
    Wang, Wei
    Wang, Shanshan
    MINERALS, 2023, 13 (08)
  • [34] Portable X-ray fluorescence (pXRF) analysis of heavy metal contamination in church graveyards with contrasting soil types
    Madden, Charles
    Pringle, Jamie K.
    Jeffery, Adam J.
    Wisniewski, Kristopher D.
    Heaton, Vivienne
    Oliver, Ian W.
    Glanville, Helen
    Stimpson, Ian G.
    Dick, Henry C.
    Eeley, Madeleine
    Goodwin, Jonathan
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (36) : 55278 - 55292
  • [35] Elemental Composition in Female Dry Femora Using Portable X-Ray Fluorescence (pXRF): Association with Age and Osteoporosis
    Sofía Zdral
    Álvaro M. Monge Calleja
    Lidia Catarino
    Francisco Curate
    Ana Luisa Santos
    Calcified Tissue International, 2021, 109 : 231 - 240
  • [36] Soil weathering analysis using a portable X-ray fluorescence (PXRF) spectrometer in an Inceptisol from the Brazilian Cerrado
    Godinho Silva, Sergio Henrique
    Hartemink, Alfred E.
    dos Santos Teixeira, Anita Fernanda
    Inda, Alberto Vasconcellos
    Guimaraes Guilherme, Luiz Roberto
    Curi, Nilton
    APPLIED CLAY SCIENCE, 2018, 162 : 27 - 37
  • [37] Diagnosing trace metals contamination in ageing stormwater constructed wetlands by portable X-ray Fluorescence Analyzer (pXRF)
    Lenormand, Eloise
    Kustner, Coralie
    Combroux, Isabelle
    Bois, Paul
    Wanko, Adrien
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 844
  • [38] Accurate Measurements of Low Z Elements in Sediments and Archaeological Ceramics Using Portable X-ray Fluorescence (PXRF)
    Johnson, Jack
    JOURNAL OF ARCHAEOLOGICAL METHOD AND THEORY, 2014, 21 (03) : 563 - 588
  • [39] Accurate Measurements of Low Z Elements in Sediments and Archaeological Ceramics Using Portable X-ray Fluorescence (PXRF)
    Jack Johnson
    Journal of Archaeological Method and Theory, 2014, 21 : 563 - 588
  • [40] Determination of lead (Pb) in contaminated soil by an enhanced field based portable X-ray fluorescence (PXRF) method
    Laiho, JVP
    Valimaki, L
    Peramaki, P
    6Th International Conference Environmental Engineering, Vols 1 and 2, 2005, : 143 - 147