Diagnostic performance for erosion detection in sacroiliac joints on MR T1-weighted images: Comparison between different slice thicknesses

被引:11
|
作者
Chen, Min [1 ]
Herregods, Nele [1 ]
Jaremko, Jacob L. [2 ]
Carron, Philippe [3 ,4 ]
Elewaut, Dirk [3 ,4 ]
Van den Bosch, Filip [3 ,4 ]
Jans, Lennart [1 ]
机构
[1] Ghent Univ Hosp, Dept Radiol, Corneel Heymanslaan 10, B-9000 Ghent, Belgium
[2] Univ Alberta Hosp, Dept Radiol & Diagnost Imaging, 8440-112 St, Edmonton, AB T6G 2B7, Canada
[3] Ghent Univ Hosp, Dept Rheumatol, Corneel Heymanslaan 10, B-9000 Ghent, Belgium
[4] Ghent Univ VIB, Inflammat Res Ctr, Unit Mol Immunol & Inflammat, Technol Pk 927, B-9052 Ghent, Belgium
关键词
Slice thickness; Magnetic resonance imaging; Spondyloarthritis; Erosion; COMPUTED-TOMOGRAPHY; STRUCTURAL LESIONS; SPONDYLOARTHRITIS; RADIOGRAPHS; FEATURES; CT;
D O I
10.1016/j.ejrad.2020.109352
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the effect of slice thickness on the diagnostic accuracy of erosion detection at MR T1-weighted images (T1WI) of the sacroiliac joints (SIJ) in adult patients suspected of sacroiliitis. Method: Patients aged 18-60 years with clinical suspicion of sacroiliitis were enrolled. All patients underwent CT and 3 T MRI of the SIJs on the same day. CT at 1 mm slice thickness, semi-coronal spin echo T1WI sequences with four different slice thicknesses (2, 3, 4 and 5 mm) were obtained. For scoring erosions, each SIJ was divided into four quadrants. Presence or absence of erosions was scored on T1WI sequences by two independent readers blinded to other data. Inter-reader agreement was assessed using kappa statistics. Diagnostic accuracy of MRI for erosions at each slice thickness was evaluated vs. consensus CT as reference standard, using area under the receiver operating characteristic curve (AUC). Results: Fifty-three patients (23 men, 30 women, mean age, 39.0 years +/- 10.2) were included. Inter-reader agreement for erosion score on all T1WI sequences was moderate (kappa value 0.54 to 0.60). With increasing slice thickness, both the recorded total number of erosions and sensitivity for erosion vs. CT decreased. The AUC were significantly higher for 2 mm and 3 mm T1WI than for 4 mm and 5 mm T1WI. Conclusions: The diagnostic accuracy of T1WI for erosion detection vs. a CT reference standard is affected by slice thickness. Thinner slices (2 or 3 mm) had significantly higher diagnostic accuracy than thicker slices (4 or 5 mm).
引用
收藏
页数:8
相关论文
共 50 条
  • [21] HYPERINTENSE DISKS ON T1-WEIGHTED MR-IMAGES - CORRELATION WITH CALCIFICATION
    BANGERT, BA
    MODIC, MT
    ROSS, JS
    OBUCHOWSKI, NA
    PERL, J
    RUGGIERI, PM
    MASARYK, TJ
    RADIOLOGY, 1995, 195 (02) : 437 - 443
  • [22] Breast lesions with high signal intensity on T1-weighted MR images
    Irmak Durur-Subasi
    Afak Durur-Karakaya
    Fatih Alper
    Adem Karaman
    Rabia Mihriban Kılıc
    Sare Sipal
    Elif Demirci
    Mufide Nuran Akcay
    Japanese Journal of Radiology, 2013, 31 : 653 - 661
  • [23] Attenuation Correction in MR-PET Scanners with Segmented T1-weighted MR Images
    Kops, Elena Rota
    Wagenknecht, Gudrun
    Scheins, Juergen
    Tellmann, Lutz
    Herzog, Hans
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2530 - +
  • [24] High signal on T1-weighted MR images of the head: A pictorial essay
    Caruso, RD
    Postel, GC
    McDonald, CS
    Sherry, RG
    CLINICAL IMAGING, 2001, 25 (05) : 312 - 319
  • [25] Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T
    Josef Vymazal
    Zuzana Ryznarova
    Aaron M. Rulseh
    Insights into Imaging, 15
  • [26] Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T
    Vymazal, Josef
    Ryznarova, Zuzana
    Rulseh, Aaron M.
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [27] MR imaging of cervical carcinoma: Comparison among T2-weighted, dynamic, and postcontrast T1-weighted images with histopathological correlation
    Tsuda, K
    Murakami, T
    Kurachi, H
    Ogawa, H
    Oi, H
    Miyake, A
    Narumi, Y
    Nakamura, H
    ABDOMINAL IMAGING, 1997, 22 (01): : 103 - 107
  • [28] Spacial Aliasing Artefact Detection on T1-Weighted MRI Images
    Teixeira, Joao F.
    Oliveira, Helder P.
    PATTERN RECOGNITION AND IMAGE ANALYSIS (IBPRIA 2017), 2017, 10255 : 462 - 470
  • [29] MR imaging of cervical carcinoma: comparison among T2-weighted, dynamic, and postcontrast T1-weighted images with histopathological correlation
    K. Tsuda
    T. Murakami
    H. Kurachi
    H. Ogawa
    H. Oi
    A. Miyake
    Y. Narumi
    H. Nakamura
    Abdominal Imaging , 1997, 22 : 103 - 107
  • [30] Comparison of different radiomic models based on enhanced T1-weighted images to predict the meningioma grade
    Duan, C. F.
    Li, N.
    Li, Y.
    Liu, F.
    Wang, J. C.
    Liu, X. J.
    Xu, W. J.
    CLINICAL RADIOLOGY, 2022, 77 (04) : E302 - E307