EXPOSURE DOSE INDEX BASED ON NOISE FACTOR ANALYSIS IN DIGITAL MAMMOGRAPHY: VERIFICATION USING DIRECT-TYPE FLAT-PANEL DETECTOR SYSTEM

被引:1
|
作者
Maruyama, Sho [1 ]
机构
[1] Gunma Paz Univ, Fac Hlth Sci, Sch Radiol Sci, 3-3-4 Tonyamachi, Takasaki, Gunma 3700006, Japan
关键词
BASIC IMAGING PROPERTIES; PHYSICAL-CHARACTERIZATION; BREAST-CANCER; RADIOGRAPHY; PERFORMANCE; QUALITY; PHANTOMS;
D O I
10.1093/rpd/ncab003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, the development of a reasonable index of optimized exposure dose is attempted. Using a direct-type flat-panel system, noise factors contained in the image are analyzed based on the relative standard deviation method, and it is verified that the proposed index conforms with the appropriate standards regarding minimum exposure dose. The findings indicate that Poisson noise is dominant in the general clinical dose range; this noise fraction formed 90% of the total noise in the system considered in this study. Considering the results of previous surveys, it is estimated that the point at which the content rate of the Poisson noise starts to decrease can be considered as the lower limit, below which the dose cannot be reduced further without compromising on image quality. As the 'index' obtained by this method can be easily measured, it is useful as a quantitative indicator for dose determination and optimization.
引用
收藏
页码:473 / 481
页数:9
相关论文
共 50 条
  • [1] Imaging and Dosimetric Study on Direct Flat-Panel Detector-Based Digital Mammography System
    Sharma, Reena
    Sharma, S. D.
    Sarkar, P. S.
    Datta, D.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 255 - 263
  • [2] Characterization of a direct, full-field flat-panel digital mammography detector
    Zhao, B
    Zhao, W
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 157 - 167
  • [3] Radiation exposure in full-field digital mammography with a selenium flat-panel detector
    Gosch, D.
    Jendrass, S.
    Scholz, M.
    Kahn, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (07): : 693 - 697
  • [4] Direct flat-panel detectors: A-Se TFT detector for full field digital mammography
    Gkanatsios, N
    MEDICAL PHYSICS, 2003, 30 (06) : 1434 - 1434
  • [5] Evaluation of a clinical prototype selenium direct-converter flat-panel detector for digital mammography
    Loustauneau, V
    Cadieux, S
    Bissonnette, M
    Hansroul, M
    Savard, S
    Polischuk, B
    MEDICAL PHYSICS, 2002, 29 (06) : 1306 - 1306
  • [6] Radiation Dose of Interventional Radiology System Using a Flat-Panel Detector
    Chida, Koichi
    Inaba, Yohei
    Saito, Haruo
    Ishibashi, Tadashi
    Takahashi, Shoki
    Kohzuki, Masahiro
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1680 - 1685
  • [7] Effects of Automatic Dose Rate Control On Patient Dose in a Digital Flat-Panel Detector System
    Lai, P. L.
    Tsai, H. L.
    Li, Y. Y.
    Tyan, Y. S.
    Tung, C. J.
    MEDICAL PHYSICS, 2009, 36 (06) : 2454 - +
  • [8] Dose reduction of radiographs of the pediatric pelvis for diagnosing hip dysplasia using a digital flat-panel detector system
    Ludwig, K
    Ahlers, K
    Sandmann, C
    Gosheger, G
    Kloska, S
    Vieth, V
    Meier, N
    Heindel, W
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (01): : 112 - 117
  • [9] Prospects for x-ray exposure reduction using digital radiography with a flat-panel detector
    Okusako, K
    Hatagawa, M
    Kishimoto, K
    Tanaka, K
    Kudo, H
    Yamada, R
    RADIOLOGY, 2001, 221 : 158 - 158
  • [10] Signal and noise analysis of a metal oxide transistor-based flat-panel detector
    Oh, Seokwon
    Yoo, Seungjun
    Shin, Hubeom
    Lee, Junho
    Kim, Dong Uk
    Kim, Ho Kyung
    JOURNAL OF INSTRUMENTATION, 2023, 18 (10)