Temperature stage matching and experimental investigation of high-temperature cascade heat pump with vapor injection

被引:32
|
作者
Zou, Huiming [1 ,2 ,3 ]
Li, Xuan [1 ,2 ,3 ]
Tang, Mingsheng [1 ,3 ]
Wu, Jiang [3 ]
Tian, Changqing [1 ,2 ,3 ]
Butrymowicz, Dariusz [4 ]
Ma, Yongde [5 ]
Wang, Jin [5 ]
机构
[1] Chinese Acad Sci, Key Lab Sci & Technol Space Energy Conversat, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[4] Bialystok Tech Univ, Wiejska 45C, PL-15351 Bialystok, Poland
[5] Guangzhou Deron Heat Source Equipment Co Ltd, Guangzhou 511495, Peoples R China
基金
中国国家自然科学基金;
关键词
Air source; Cascade heat pump; Vapor injection; Large temperature elevation; Temperature stage matching;
D O I
10.1016/j.energy.2020.118734
中图分类号
O414.1 [热力学];
学科分类号
摘要
High-temperature cascade heat pump has remarkable development potential for industrial heat generation due to its superiority in energy-saving and environment friendly. But the growing demand for higher temperature difference heating challenges the traditional cascade heat pump. One of practical solutions is the combination of cascade system and vapor injection technique. However, the introduction of vapor injection increases the complexity of the system, and the interaction between branches and the distributions of branches are to be studied to give full play to the best performance of the vapor injected cascade system. This paper focuses on temperature stage matching between the heat exchange branches of a cascade air source heat pump with vapor injection to get optimal heating performance. The optimal configurations of intermediate temperature and vapor injection branch temperature are obtained based on the optimal method. A cascade heat pump prototype with refrigerant R245fa and R410A is developed and investigated experimentally to verify the optimization method. The cascade air source heat pump could realize 140 degrees C heat supply and the coefficient of performance is from 1.16 to 1.58 under the ambient temperature of from-10 degrees C to 20 degrees C. (c) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Advanced Exergy and Exergoeconomic Analysis of Cascade High-Temperature Heat Pump System for Recovery of Low-Temperature Waste Heat
    Hu, Xiaowei
    Shi, Chenyang
    Liu, Yong
    Fu, Xingyu
    Ma, Tianyao
    Jin, Mingsen
    [J]. ENERGIES, 2024, 17 (05)
  • [22] Experimental investigation on matching a conventional water source heat pump with different refrigerants for supplying high temperature water
    Deng, Na
    Gao, Jian
    Cai, Rongchang
    Jing, Xiaoyu
    Zhang, Yufeng
    Hao, Ruisen
    Li, Minxia
    [J]. APPLIED THERMAL ENGINEERING, 2020, 166
  • [23] Numerical investigation on high-temperature thermoacoustic heat pump with a work recovery displacer
    Ye, Tian
    Chen, Xi
    Zhu, Shenglin
    Wu, Yankang
    Zheng, Pu
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2024, 30 (02) : 172 - 183
  • [24] HIGH TEMPERATURE CASCADE HEAT PUMP SYSTEM WITH DOUBLE MEDIUM AND LOW TEMPERATURE HEAT SOURCES
    Cui, Siqi
    Geng, Shuwei
    Bai, Jing
    Zhang, Yi
    Guan, Size
    Yang, Hanfei
    [J]. THERMAL SCIENCE, 2023, 27 (3A): : 1835 - 1843
  • [25] Performance analysis and multi-objective optimization of the high-temperature cascade heat pump system
    Wu, Zhangxiang
    Wang, Xiaoyan
    Sha, Li
    Li, Xiaoqiong
    Yang, Xiaochen
    Ma, Xuelian
    Zhang, Yufeng
    [J]. ENERGY, 2021, 223
  • [26] Performance Comparison of High-Temperature Heat Pumps with Different Vapor Refrigerant Injection Techniques
    Yang, Yuqiang
    Wang, Yu
    Xu, Zhaoyang
    Xie, Baojiang
    Hu, Yong
    Yu, Jiatao
    Chen, Yehong
    Zhang, Ting
    Lu, Zhenneng
    Gong, Yulie
    [J]. PROCESSES, 2024, 12 (03)
  • [27] Experimental Study of a Water Vapor Compression Heat Pump With Very High Temperature Output
    Hu, Bin
    Wu, Di
    Jiang, Jia-Tong
    Wang, Ru-Zhu
    Yu, Jing-Jing
    Li, Zi-Liang
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (04): : 833 - 840
  • [28] Experimental Investigation of Trans-critical CO2 Heat Pump High-Temperature Water Heater
    Zhu, Yin-Hai
    Li, Cong-Hui
    Jiang, Pei-Xue
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2018, 39 (10): : 2113 - 2117
  • [29] Performance of a single-stage recuperative high-temperature air source heat pump
    Sun, Shoujun
    Guo, Hao
    Lu, Ding
    Bai, Yin
    Gong, Maoqiong
    [J]. APPLIED THERMAL ENGINEERING, 2021, 193
  • [30] Energy, exergy, economic and environmental analyses and optimization of a novel vapor injection autocascade heat pump for high-temperature water heating
    Chen, Jiaheng
    Chen, Qi
    Qin, Xiang
    Wang, Dingbiao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2022, 267