Determination of myo-inositol in infant formulae and milk powders using capillary gas chromatography with flame ionisation detection

被引:22
|
作者
Woollard, David C. [1 ]
Macfadzean, Craig [2 ]
Indyk, Harvey E. [3 ]
McMahon, Adrienne [4 ]
Christiansen, Scott [5 ]
机构
[1] R J Hill Labs Ltd, Food & Bioanalyt Div, Hamilton 3216, New Zealand
[2] New Zealand Lab Serv Ltd, Auckland 1476, New Zealand
[3] Fonterra Cooperat Grp Ltd, Waitoa, New Zealand
[4] Wyeth Nutr, Askeaton, Limerick, Ireland
[5] Perrigo Nutr PBM Prod, Gordonsville, VA 22942 USA
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; PHYTIC ACID; INOSITOL; FOODS; DERIVATIVES; HYDROLYSIS; ASSAY;
D O I
10.1016/j.idairyj.2014.03.004
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A gas chromatographye-flame ionisation detection method was developed to establish the content of myo-inositol in milk powders and infant formulations subsequent to formation of the volatile trialkylsilyl derivative. Samples were prepared by acid digestion, thereby releasing inositol from its multiple bound forms. A digestion time of 4 h at 114 degrees C was sufficient to hydrolyse potentially interfering carbohydrates and quantitatively recover bound inositol from milk-based products. Single laboratory method validation showed a within-day relative standard deviation (RSDr) of 5.9% and between-day relative standard deviation (RSDiR) of 9.6%. A between-laboratory (n - 7) collaborative study yielded an average reproducibility (RSDR) of 12.8%, considered fit-for-purpose as a quality control method for milk-based infant formulations. Soy-based products, containing significant inositol hexaphosphate (IP6, phytic acid), required 32 h for release of all inositol. Although current regulations do not specify the inclusion of IP6 in an inositol measurement, the current method allows for its discrimination if present. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:74 / 81
页数:8
相关论文
共 50 条
  • [41] GAS-CHROMATOGRAPHY OF SOME METAL DIALKYLDITHIOPHOSPHATES WITH PACKED AND CAPILLARY COLUMNS USING FLAME PHOTOMETRIC DETECTION
    MARRIOTT, PJ
    CARDWELL, TJ
    JOURNAL OF CHROMATOGRAPHY, 1982, 234 (01): : 157 - 169
  • [42] DEVELOPMENT AND VALIDATION OF A METHOD FOR ANALYSIS OF ORGANOPHOSPHATE RESIDUES IN MILK USING GAS CHROMATOGRAPHY WITH FLAME PHOTOMETRIC DETECTION
    Pinto Bastos, Lucia Helena
    Gouvea, Adherlene Vieira
    Malaga, Fabiola
    Wohlers Morelli Cardoso, Maria Helena
    Jacob, Silvana do Couto
    da Nobrega, Armi Wanderley
    QUIMICA NOVA, 2012, 35 (08): : 1657 - U206
  • [43] Development of a capillary gas chromatographic method with flame ionisation detection for the simultaneous determination of sildenafil and its N-demethylated metabolite in biological fluids
    Nevado, JJB
    Llerena, MJV
    Salcedo, AMC
    Flores, JR
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (12) : 767 - 772
  • [44] Chemical fingerprinting of petrochemicals for arson investigations using two-dimensional gas chromatography - flame ionisation detection and multivariate analysis
    Pandohee, Jessica
    Hughes, Jeff G.
    Pearson, James R.
    Jones, Oliver A. H.
    SCIENCE & JUSTICE, 2020, 60 (04) : 381 - 387
  • [45] DETERMINATION OF AMITROLE IN PLANT-TISSUES AND SANDY SOILS BY CAPILLARY GAS-CHROMATOGRAPHY WITH ALKALI FLAME IONIZATION DETECTION
    VANDERPOLL, JM
    VINK, M
    QUIRIJNS, JK
    CHROMATOGRAPHIA, 1990, 30 (3-4) : 155 - 158
  • [46] Simultaneous determination of anthraquinones in radix Polygoni multiflori by capillary gas chromatography coupled with flame ionization and mass spectrometric detection
    Zuo, Yuegang
    Wang, Chengjun
    Lin, Yuejuan
    Guo, Jinwen
    Deng, Yiwei
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (01) : 43 - 48
  • [47] Determination of volatile fatty acids in tofu wastewater by capillary gas chromatography with flame ionization detection: A Comparison of extraction methods
    Rosmalina, R. T.
    Widyarani
    Hamidah, U.
    Sintawardani, N.
    PROCEEDING OF THE 4TH INTERNATIONAL SYMPOSIUM ON GREEN TECHNOLOGY FOR VALUE CHAINS 2019, 2020, 483
  • [48] AUTOMATED CAPILLARY GAS-CHROMATOGRAPHIC ASSAY USING FLAME IONIZATION DETECTION FOR THE DETERMINATION OF TOPIRAMATE IN PLASMA
    HOLLAND, ML
    UETZ, JA
    NG, KT
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 433 : 276 - 281
  • [49] Determination of toluene-2,4-diisocyanate in environmental and workplace air by sampling onto Tenax-TA followed by thermal desorption and capillary gas chromatography using flame ionisation and ion-trap detection
    Bianchi, AP
    Joyner, TKB
    JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) : 233 - 239
  • [50] Packed capillary column solvating gas chromatography using neat water mobile phase and flame ionization detection
    Wu, NJ
    Tang, QL
    Lippert, JA
    Lee, ML
    JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (02) : 41 - 47