Accuracy and Repeatability of Limb Scans Obtained on the Semi-Automatic Measuring Station

被引:0
|
作者
Wichniarek, Radoslaw [1 ]
Gorski, Filip [1 ]
Kuczko, Wieslaw [1 ]
Zukowska, Magdalena [1 ]
机构
[1] Poznan Univ Tech, Chair Prod Engn & Management, Poznan, Poland
关键词
medical device; limb scanning; semi-automatic scanning; anthropometric data;
D O I
10.12913/22998624/127011
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Designing individualized medical devices requires the collection of anthropometric data from the patient. This can be done by using the 3D scanning process. Despite many advantages, it has significant drawbacks, limiting the suitability of its use for many types of medical devices. This paper presents the design of measuring station that allows increasing the quality of the anthropometric data obtained in the scanning process of human limbs. The accuracy and repeatability of the data obtained on the station was presented and compared to reference scans. Moreover, owing to the automation of certain activities in the scanning process, operating the device requires the operator to have much lower competencies and workload.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 50 条
  • [31] USE OF SEMI-AUTOMATIC MEASURING DEVICES FOR THE INSPECTION OF CAR BODIES IN AUTOMOBILE MANUFACTURE
    KIRSTEIN, H
    BOTT, E
    TECHNISCHES MESSEN, 1983, 50 (05): : 197 - 202
  • [32] Virtual colonoscopy: A technique for semi-automatic lesion detection in scans from CT, EBT and MRI
    Haubner, M
    Scheidler, JE
    Englmeier, KH
    RADIOLOGY, 1998, 209P : 430 - 430
  • [33] Accuracy Assessment of Semi-Automatic Measuring Techniques Applied to Displacement Control in Self-Balanced Pile Capacity Testing Appliance
    Muszynski, Zbigniew
    Rybak, Jaroslaw
    Kaczor, Paulina
    SENSORS, 2018, 18 (11)
  • [34] Semi-automatic inspection tool of pavement condition from three-dimensional profile scans
    Garbowski, Tomasz
    Gajewski, Tomasz
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 310 - 318
  • [35] Accuracy and Correlation of the Kinect-Based Semi-Automatic Scoring Method for Measuring Anomalous Head Posture as Compared to the CROM® Device
    Yamamoto, Mana
    Yagasaki, Teiji
    Ichikawa, Sho
    Nakamura, Takuto
    Konishi, Yuumi
    Yokoyama, Yoshimi
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 4033 - 4040
  • [36] Ultrasound applied for measuring uncompressed sat: accuracy and inter-observer reliability obtainable with a semi-automatic image segmentation software
    Mueller, Wolfram
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 : S6 - S6
  • [37] Semi-automatic measurements of foot morphological parameters from 3D plantar foot scans
    Giulia Rogati
    Alberto Leardini
    Maurizio Ortolani
    Paolo Caravaggi
    Journal of Foot and Ankle Research, 14
  • [38] Clinical evaluation of semi-automatic landmark-based lesion tracking software for CT-scans
    Dankerl, Peter
    Cavallaro, Alexander
    Dietzel, Matthias
    Tsymbal, Alexey
    Kramer, Martin
    Seifert, Sascha
    Uder, Michael
    Hammon, Matthias
    CANCER IMAGING, 2014, 14
  • [39] Semi-automatic analysis of Winston-Lutz film images to assess isocentric accuracy
    Kouwenhoven, E.
    Van Egmond, J.
    Van Santvoort, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S490 - S490
  • [40] SEMI-AUTOMATIC APPARATUS FOR MEASURING THE VAPOR-PRESSURE OF PASTES UNDER STATIC CONDITIONS
    KALZ, G
    PUSCHEL, A
    PLASTE UND KAUTSCHUK, 1984, 31 (09): : 336 - 337