Modeling of Corona Discharge on a Transmission Line Conductor Struck by Lightning for FDTD Calculations

被引:0
|
作者
Tran Huu Thang [1 ]
Baba, Yoshihiro [1 ]
Nagaoka, Naoto [1 ]
Ametani, Akihiro [1 ]
Takami, Jun [2 ]
Okabe, Shigemitsu [2 ]
Rakov, Vladimir A. [3 ]
机构
[1] Doshisha Univ, Kyoto 6100321, Japan
[2] Tokyo Elect Power Co Ltd, R&D Ctr, Yokohama, Kanagawa 2308510, Japan
[3] Univ Florida, Gainesville, FL 32611 USA
关键词
SURGE SIMULATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have modeled corona discharge from an overhead wire struck by lightning for surge and electromagnetic-pulse calculations using the finite-difference time -domain (FDTD) method. The radial progression of corona discharge from the wire is represented as the radial expansion of conducting region whose conductivity is several tens of micro Siemens per meter. The critical electric field on the surface of a 5-mm-radius wire for emanating corona is set to E-0=1.8 or 2.7 MV/m. The critical electric field at the boundary of radial corona sheath is set to E-c(+) =0.5 MV/m for positive voltage application, and E-c(-)=1.5 MV/m for negative voltage application. The calculated waveform of radial corona-discharge current agrees well with the corresponding waveform measured by Noda. Also, the calculated relation between the total charge (charge deposited on the wire and emanated corona charge) and applied voltage (q-V curves) agrees well with the corresponding measured one. Further, the expected increase of coupling between the energized wire and another one nearby due to corona discharge is well simulated.
引用
收藏
页码:1309 / 1312
页数:4
相关论文
共 50 条
  • [11] Measurement of lightning surges on test transmission line equipped with arresters struck by natural and triggered lightning
    Hokuriku Electric Power Co, Toyama, Japan
    IEEE Trans Power Delivery, 2 (996-1002):
  • [12] Measurement of lightning surges on test transmission line equipped with arresters struck by natural and triggered lightning
    Matsumoto, Y
    Sakuma, O
    Shinjo, K
    Saiki, M
    Wakai, T
    Sakai, T
    Nagasaka, H
    Motoyama, H
    Ishii, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 996 - 1002
  • [13] The voltage induced in a transmission line by a lightning discharge
    Murray, FH
    AMERICAN JOURNAL OF MATHEMATICS, 1933, 55 : 119 - 125
  • [14] Study on corona discharge on the grounding wire of ±1100 kV transmission line during the downward lightning flash
    An, Yunzhu
    Yang, Jian
    Hu, Yuanchao
    Sha, Xiao
    Wang, Qingchen
    Lin, Yitong
    Su, Menghan
    Yin, Kaiqiang
    Yang, Minghao
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 233
  • [15] Influence of contaminations of the conductor on HVDC transmission line corona characteristics
    Zhao, Yu-Ming
    Ma, Min-Hua
    Guan, Zhi-Cheng
    Hui, Jian-Feng
    Wang, Li-Ming
    Li, Qiu-Wei
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (12): : 49 - 54
  • [16] LIGHTNING SURGE CALCULATIONS INCLUDING CORONA EFFECTS USING A 2-CONDUCTOR MODEL
    NAGAOKA, N
    MOTOYAMA, H
    AMETANI, A
    ELECTRIC POWER SYSTEMS RESEARCH, 1987, 13 (01) : 31 - 41
  • [17] Modeling of Partial Discharge in Transformer Winding by Multi-Conductor Transmission Line Model
    Hosseini, S. M. Hassan
    Vakilian, M.
    Niasar, M. Ghaffarian
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (02): : 3926 - 3934
  • [18] Research on antenna for detecting the corona discharge of transmission line
    Xia, Yunfeng
    Song, Xinming
    Jia, Zhidong
    Wang, Xilin
    Qi, Jinfeng
    Xu, Zheng
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2965 - 2968
  • [19] The Impact of Transmission Line Modeling on Lightning Overvoltage
    Leon Colqui, Jaimis Sajid
    Ribeiro de Moura, Rodolfo Antonio
    De Oliveira Schroeder, Marco Aurelio
    Pissolato Filho, Jose
    Kurokawa, Sergio
    ENERGIES, 2023, 16 (03)
  • [20] Modeling transmission line circuit elements in the FDTD method
    Montoya, TP
    Smith, GS
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1999, 21 (02) : 105 - 114