Q-priming PCR: A quantitative real-time PCR system using a self-quenched BODIPY FL-labeled primer

被引:3
|
作者
Liu, Xiao Kun [1 ]
Hong, Yan [1 ]
机构
[1] Natl Univ Singapore, Temasek Life Sci Lab, Singapore 117604, Singapore
关键词
D O I
10.1016/j.ab.2006.10.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
[No abstract available]
引用
收藏
页码:154 / 156
页数:3
相关论文
共 50 条
  • [1] Multiplex quantitative PCR using self-quenched primers labeled with a single fluorophore
    Nazarenko, I
    Lowe, B
    Darfler, M
    Ikonomi, P
    Schuster, D
    Rashtchian, A
    [J]. NUCLEIC ACIDS RESEARCH, 2002, 30 (09) : e37
  • [2] Quantitative detection of Aeromonas salmonicida in fish tissue by real-time PCR using self-quenched, fluorogenic primers
    Luis Balcazar, Jose
    Vendrell, Daniel
    de Blas, Ignacio
    Ruiz-Zarzuela, Imanol
    Girones, Olivia
    Luis Muzquiz, Jose
    [J]. JOURNAL OF MEDICAL MICROBIOLOGY, 2007, 56 (03) : 323 - 328
  • [3] Fluorescent quenching-based quantitative detection of specific DNA/RNA using a BODIPY® FL-labeled probe or primer
    Kurata, Shinya
    Kanagawa, Takahiro
    Yamada, Kazutaka
    Torimura, Masaki
    Yokomaku, Toyokazu
    Kamagata, Yoichi
    Kurane, Ryuichiro
    [J]. NUCLEIC ACIDS RESEARCH, 2001, 29 (06)
  • [4] DETECTION OF CONTAMINATION BY QUANTITATIVE REAL-TIME (Q) PCR
    Bohrer, C. L.
    Tao, X.
    Torpey, E. L.
    Taylor, D.
    Scott, R. T., Jr.
    Treff, N. R.
    [J]. FERTILITY AND STERILITY, 2013, 100 (03) : S206 - S206
  • [5] Application of self-quenched JH consensus primers for real-time quantitative PCR of IGH gene to minimal residual disease evaluation in multiple myeloma
    Martinez-Lopez, Joaquin
    Martinez-Sanchez, Pilar
    Garcia-Sanz, Ramon
    Sarasquete, Maria Eugenia
    Ayala, Rosa
    Gonzalez, Marcos
    Bautista, Jose Manuel
    Gonzalez, David
    San Miguel, Jesus
    Garcia-Effron, Guillermo
    Lahuerta, Juan Jose
    [J]. JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (03): : 364 - 370
  • [6] Development of a multiplex adaptation of a quantitative real time-PCR method using self-quenched, fluorogenic LUX primers for detection of staphylococcal enterotoxin genes
    Fischer, A
    von Eiff, C
    Schulte, M
    Peters, G
    Becker, K
    [J]. INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2004, 294 : 141 - 141
  • [7] Quantitative measurement of streptomycetes using real-time PCR
    Rintala, Helena
    Nevalainen, Aino
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (07): : 745 - 749
  • [8] Validation and Application of a PCR Primer Set to Quantify Fungal Communities in the Soil Environment by Real-Time Quantitative PCR
    Prevost-Boure, Nicolas Chemidlin
    Christen, Richard
    Dequiedt, Samuel
    Mougel, Christophe
    Lelievre, Melanie
    Jolivet, Claudy
    Shahbazkia, Hamid Reza
    Guillou, Laure
    Arrouays, Dominique
    Ranjard, Lionel
    [J]. PLOS ONE, 2011, 6 (09):
  • [9] A fluorescence detection optical system for real-time quantitative PCR
    Ma Yu-tonga
    Zeng Liang
    Zhang Jian-huan
    [J]. OPTICAL DESIGN AND TESTING X, 2020, 11548
  • [10] Real-Time Quantitative PCR: Primer Design, Reference Gene Selection, Calculations and Statistics
    Chen, Zhiwei
    Halford, Nigel G.
    Liu, Chenghong
    [J]. METABOLITES, 2023, 13 (07)