Dosimetric analysis of the alopecia preventing effect of hippocampus sparing whole brain radiation therapy

被引:14
|
作者
Mahadevan, Anand [1 ,2 ]
Sampson, Carrie [1 ,2 ]
LaRosa, Salvatore [1 ,2 ]
Floyd, Scott R. [1 ,2 ]
Wong, Eric T. [2 ,3 ]
Uhlmann, Erik J. [2 ,3 ]
Sengupta, Soma [2 ,3 ]
Kasper, Ekkehard M. [2 ,4 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiat Oncol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
[3] Beth Israel Deaconess Med Ctr, Dept Neurooncol, Boston, MA 02215 USA
[4] Beth Israel Deaconess Med Ctr, Dept Neurosurg, Boston, MA 02215 USA
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
Hippocampus sparing; Alopecia; IMRT; QUALITY-OF-LIFE; PROPHYLACTIC CRANIAL IRRADIATION; CELL LUNG-CANCER; PHASE-III TRIAL; STEREOTACTIC RADIOSURGERY; NEUROCOGNITIVE FUNCTION; PERMANENT ALOPECIA; SURGICAL RESECTION; METASTASES; RADIOTHERAPY;
D O I
10.1186/s13014-015-0555-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Whole brain radiation therapy (WBRT) is widely used for the treatment of brain metastases. Cognitive decline and alopecia are recognized adverse effects of WBRT. Recently hippocampus sparing whole brain radiation therapy (HS-WBRT) has been shown to reduce the incidence of memory loss. In this study, we found that multi-field intensity modulated radiation therapy (IMRT), with strict constraints to the brain parenchyma and to the hippocampus, reduces follicular scalp dose and prevents alopecia. Methods: Suitable patients befitting the inclusion criteria of the RTOG 0933 trial received Hippocampus sparing whole brain radiation. On follow up, they were noticed to have full scalp hair preservation. 5 mm thickness of follicle bearing scalp in the radiation field was outlined in the planning CT scans. Conventional opposed lateral WBRT radiation fields were applied to these patient-specific image sets and planned with the same nominal dose of 30 Gy in 10 fractions. The mean and maximum dose to follicle bearing skin and Dose Volume Histogram (DVH) data were analyzed for conventional and HS-WBRT. Paired t-test was used to compare the means. Results: All six patients had fully preserved scalp hair and remained clinically cognitively intact 1-3 months after HS-WBRT. Compared to conventional WBRT, in addition to the intended sparing of the Hippocampus, HS-WBRT delivered significantly lower mean dose (22.42 cGy vs. 16.33 cGy, p < 0.0001), V24 (9 cc vs. 44 cc, p < 0.0000) and V-30 (9 cc vs. 0.096 cc, p = 0.0106) to follicle hair bearing scalp and prevented alopecia. There were no recurrences in the Hippocampus area. Conclusions: HS-WBRT, with an 11-field set up as described, while attempting to conserve hippocampus radiation and maintain radiation dose to brain inadvertently spares follicle-bearing scalp and prevents alopecia.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Dosimetric evaluation of four whole brain radiation therapy approaches with hippocampus and inner ear avoidance and simultaneous integrated boost for limited brain metastases
    Aijun Jiang
    Weipeng Sun
    Fen Zhao
    Zhenxuan Wu
    Dongping Shang
    Qingxi Yu
    Suzhen Wang
    Jian Zhu
    Fengchang Yang
    Shuanghu Yuan
    Radiation Oncology, 14
  • [22] Dosimetric evaluation of four whole brain radiation therapy approaches with hippocampus and inner ear avoidance and simultaneous integrated boost for limited brain metastases
    Jiang, Aijun
    Sun, Weipeng
    Zhao, Fen
    Wu, Zhenxuan
    Shang, Dongping
    Yu, Qingxi
    Wang, Suzhen
    Zhu, Jian
    Yang, Fengchang
    Yuan, Shuanghu
    RADIATION ONCOLOGY, 2019, 14
  • [23] Generalized equivalent uniform dose-based biological optimization in hippocampus-sparing whole-brain radiation therapy
    Won, Young Jin
    Lee, Eungman
    Cho, Sam Ju
    Kim, Kyung Su
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 79 (12) : 1171 - 1179
  • [24] Generalized equivalent uniform dose-based biological optimization in hippocampus-sparing whole-brain radiation therapy
    Young Jin Won
    Eungman Lee
    Sam Ju Cho
    Kyung Su Kim
    Journal of the Korean Physical Society, 2021, 79 : 1171 - 1179
  • [25] Dosimetric Comparison of Four Volumetric-Modulated Arc Therapy Beam Arrangements Utilized for Hippocampal-Sparing Whole-Brain Radiation Therapy
    Prado, Alejandro
    Isabel Milanes, Ana
    Cabello, Eduardo
    Diaz, Raul
    Ferrando, Alejandro
    Pozo, Gustavo
    Leonor, Mario
    Manzano, Marta
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (01) : 1 - 8
  • [26] A dosimetric study of the effect of respiratory motion on whole breast radiation therapy
    Cao, J.
    Roeske, J.
    Schumra, S.
    Salama, J.
    Shoushtari, A.
    Boyer, A.
    Martel, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2403 - 2403
  • [27] Scalp and ear sparing whole brain radiation therapy using helical tomotherapy
    Limmer, J. P.
    Buskerud, J.
    Henrich, D.
    Adkins, R.
    Mullins, V.
    Welsh, J. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S729 - S729
  • [28] Automated VMAT planning for whole brain irradiation with hippocampus sparing
    Krayenbuehl, J.
    Di Martino, M.
    Guckenberger, M.
    Andratschke, N.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S849 - S849
  • [29] Hippocampus sparing whole brain radiotherapy planning with a biologic model
    Michael, Iff
    Iff, M.
    Krayenbuehl, J.
    Guckenberger, M.
    Wilke, L.
    Tanadini-Lang, S.
    Andratschke, N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1139 - 1139
  • [30] Optimizing Patient Positioning for Intensity Modulated Radiation Therapy in Hippocampal-Sparing Whole Brain Radiation Therapy
    Siglin, J. J.
    Chapman, K.
    Vakhnenko, Y.
    Witek, M.
    Harrison, A.
    Xiao, Y.
    Liu, H.
    Dicker, A.
    Shi, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S789 - S789