Combining count- and length-based z-scores leads to improved predictions in non-invasive prenatal testing

被引:13
|
作者
Budis, Jaroslav [1 ,2 ,3 ]
Gazdarica, Juraj [2 ,4 ]
Radvanszky, Jan [2 ,5 ]
Szucs, Gabor [6 ]
Kucharik, Marcel [7 ]
Strieskova, Lucia [2 ,4 ]
Gazdaricova, Iveta [4 ]
Harsanyova, Maria [2 ,4 ]
Duris, Frantisek [2 ,3 ]
Minarik, Gabriel [7 ]
Sekelska, Martina [7 ]
Nagy, Balint [8 ]
Turna, Jan [3 ,4 ,9 ]
Szemes, Tomas [2 ,4 ,9 ]
机构
[1] Comenius Univ, Fac Math Phys & Informat, Dept Comp Sci, Bratislava 84248, Slovakia
[2] Geneton Sro, Bratislava 84104, Slovakia
[3] Slovak Ctr Sci & Tech Informat, Bratislava 81104, Slovakia
[4] Comenius Univ, Fac Nat Sci, Dept Mol Biol, Bratislava 84215, Slovakia
[5] Slovak Acad Sci, Biomed Res Ctr, Inst Clin & Translat Res, Bratislava 84505, Slovakia
[6] Comenius Univ, Dept Appl Math & Stat, Fac Math Phys & Informat, Bratislava 84248, Slovakia
[7] Medirex As, Bratislava 82016, Slovakia
[8] Univ Debrecen, Dept Human Genet, H-4032 Debrecen, Hungary
[9] Comenius Univ, Sci Pk, Bratislava 84104, Slovakia
关键词
CELL-FREE DNA; SEX CHROMOSOMAL ANEUPLOIDIES; COPY NUMBER VARIATIONS; MATERNAL PLASMA DNA; FREE FETAL DNA; MOSAICISM; DIAGNOSIS; ABNORMALITIES; TRISOMY-21;
D O I
10.1093/bioinformatics/bty806
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Motivation: Non-invasive prenatal testing or NIPT is currently among the top researched topic in obstetric care. While the performance of the current state-of-the-art NIPT solutions achieve high sensitivity and specificity, they still struggle with a considerable number of samples that cannot be concluded with certainty. Such uninformative results are often subject to repeated blood sampling and re-analysis, usually after two weeks, and this period may cause a stress to the future mothers as well as increase the overall cost of the test. Results: We propose a supplementary method to traditional z-scores to reduce the number of such uninformative calls. The method is based on a novel analysis of the length profile of circulating cell free DNA which compares the change in such profiles when random-based and length-based elimination of some fragments is performed. The proposed method is not as accurate as the standard z-score; however, our results suggest that combination of these two independent methods correctly resolves a substantial portion of healthy samples with an uninformative result. Additionally, we discuss how the proposed method can be used to identify maternal aberrations, thus reducing the risk of false positive and false negative calls. Availability and implementation: The open-source code of the proposed methods, together with test data, is freely available for non-commercial users at github web page https://github.com/jbudis/lambda.
引用
收藏
页码:1284 / 1291
页数:8
相关论文
共 50 条
  • [31] EVALUATING COVERAGE EXPANSION FOR NON-INVASIVE PRENATAL TESTING THROUGH A PERFORMANCE-BASED RISK SHARING AGREEMENT
    McQueen, R. B.
    Schroeder, B.
    Wright, G.
    Barlow, J. F.
    Sherman, M.
    VALUE IN HEALTH, 2019, 22 : S636 - S636
  • [32] Circulating free DNA digestion in microfluidic devices based on lab-on-a-chip in Non-invasive prenatal testing
    Rodriguez-Martinez, A.
    Sarasola-Diez, E.
    Agirregabiria, M.
    Ruano-Lopez, J. M.
    Codd, T.
    Ward, K. R.
    Bekacz, J.
    Gaboyard, M.
    Garcia-Barcina, M.
    EUROPEAN JOURNAL OF HUMAN GENETICS, 2018, 26 : 636 - 637
  • [33] Detection of complete molar pregnancy by single-nucleotide polymorphism-based non-invasive prenatal testing
    Simon, A. L.
    Su, B.
    Demko, Z.
    Rabinowitz, M.
    Harmon, E. R.
    Gross, S. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 46 (04) : 506 - 507
  • [34] NOVEL NEXT-GENERATION SEQUENCE BASED ASSAY FOR NON-INVASIVE PRENATAL TESTING OF SICKLE CELL DISEASE
    Itzep, Nelda
    PEDIATRIC BLOOD & CANCER, 2019, 66
  • [35] Next Generation Sequencing Based Non-invasive Prenatal Testing (NIPT): First Report From Saudi Arabia
    Alyafee, Yusra
    Al Tuwaijri, Abeer
    Alam, Qamre
    Umair, Muhammad
    Haddad, Shahad
    Alharbi, Mashael
    Ballow, Maryam
    Al Drees, Mohammed
    AlAbdulrahman, Abdulkareem
    Al Khaldi, Aziza
    Alfadhel, Majid
    FRONTIERS IN GENETICS, 2021, 12
  • [36] Targeted sequencing of maternal plasma for haplotype-based non-invasive prenatal testing of spinal muscular atrophy
    Chen, M.
    Lu, S.
    Lai, Z. F.
    Chen, C.
    Luo, K.
    Yuan, Y.
    Wang, Y. S.
    Li, S. Q.
    Gao, Y.
    Chen, F.
    Asan
    Chen, D. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 49 (06) : 799 - 802
  • [37] Application of Improved ResNet18 Based Neural Network for Non-invasive Blood Glucose Testing
    Wang, Ding
    Wu, Yingnian
    Tan, Hao
    Sheng, Meiqi
    Yang, Rui
    Cao, Rongmin
    Chen, Wenbai
    INTELLIGENT NETWORKED THINGS, CINT 2024, PT II, 2024, 2139 : 3 - 11
  • [38] Economic Impact of Coverage Expansion for Non-invasive Prenatal Testing Through a Performance-Based Risk-Sharing Agreement
    Quinlan, Taryn A. G.
    Schroeder, Brock
    Kwon, Sue
    Barlow, Jane F.
    Sherman, Michael S.
    Anderson, Heather D.
    Wright, Garth
    McQueen, R. Brett
    PHARMACOECONOMICS-OPEN, 2021, 5 (03) : 449 - 458
  • [39] 'Screening should not be based on ability to pay': Australian healthcare providers' and consumers' perspectives on public funding for non-invasive prenatal testing
    Pynaker, Cecilia
    Johnston, Molly
    Mills, Catherine
    Vasey, Katie
    Taylor-Sands, Michelle
    Bowman-Smart, Hilary
    Hui, Lisa
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2025,
  • [40] Clinical utility and cost of non-invasive prenatal testing with cfDNA analysis in high-risk women based on a US population
    Song, Ken
    Musci, Thomas J.
    Caughey, Aaron B.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2013, 26 (12): : 1180 - 1185