Development of Validated Stability-indicating RP-HPLC Method for Determination of Novel Directly Acting Antiviral agent and Characterization of its Degradants by LC-ESI-MS

被引:0
|
作者
Agarwal, Babita [1 ]
Gandhi, Santosh [2 ]
机构
[1] Marathwada Mitra Mandals Coll Pharm, Dept Pharmaceut Chem, Pune, Maharashtra, India
[2] AISSMS Coll Pharm, Dept Pharmaceut Chem, Pune, Maharashtra, India
关键词
RP-HPLC; LC-ESI-MS; Ledipasvir; Stability indicating ICH method; Validation; Degradation pathway; HEPATITIS-C; SOFOSBUVIR; DACLATASVIR; SIMEPREVIR; LEDIPASVIR; RIBAVIRIN; DASABUVIR; MS/MS;
D O I
10.5530/ijper.54.4.212
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Aim: The current study was performed to develop and validate stability indicating high performance liquid chromatography method (RP-HPLC) for determination of ledipasvir (LPR); to identify and characterize its major degradants by liquid chromatographic-tandem mass spectrometric method (LC-ESI-MS). Materials and Methods: The method was developed using reverse phase gradient elution and validated for standard ICH parameters. The optimized mobile phase comprised of acetonitrile: water with 0.2 % formic acid (70:30% v/v) at 1 ml/min flow rate with satisfactory retention time (tR), theoretical plates and good resolution of LPR and its degradants. Further, forced degradation under acid, base, thermal, photolytic and oxidative stress conditions was studied as per ICH guidelines. LC-ESI-MS with time of flight analyser was used to characterize the degradants. The degradation pathways for major degradants were proposed. Results: The developed method had retention time of 6 mins. The RSD for system was found to be less than 2% whereas mean recovery was obtained 97.2 - 102.5%. Linearity range of 5-30 mu g/ml with 0.998 regression coefficient (R-2) was observed. Detection and quantification limits were obtained as 0.010 mu g/mL and 0.032 mu g/mL, respectively. LPR was stable in photolytic and thermal environments whereas degraded in acid, base and oxidative states. LC-ESI-MS was used effectively for characterization and structural elucidation of degradants. Conclusion: The results indicated that validated RP-HPLC technique can be employed for routine analysis of LPR in bulk and dosage formulas and also would be capable of separating degradants from analyte peak.
引用
收藏
页码:1159 / 1168
页数:10
相关论文
共 50 条
  • [21] Validation of Stability-Indicating RP-HPLC Method and Determination of Impurities by LC-QTOF-MS for Adenosine in Eye Drops
    Caliskan, Cem
    Koyuncu, Ikbal
    JOURNAL OF AOAC INTERNATIONAL, 2022, 105 (04) : 950 - 956
  • [22] Development of a New Validated Stability Indicating RP-HPLC Method for the Determination of Irbesartan and Hydrochlorothiazide
    Srinivasu, Topalli
    Annapurna, Mukthinuthalapati Mathrusri
    ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (01) : S333 - S339
  • [23] Development and Validation of Stability-Indicating RP-HPLC Method for Determination of Indapamide and Amlodipine Besylate
    Gandhi, Santosh V.
    Karad, Madhuri M.
    Deshpande, Padmanabh B.
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2014, 48 (02) : 48 - 54
  • [24] Validated RP-HPLC method for the simultaneous determination of glucosamine sulphate and curcumin in cream formulation: A novel stability-indicating study
    Imran, Kashif
    Syed, Haroon Khalid
    Asghar, Sajid
    Irfan, Muhammad
    Ullah, Malik Saad
    Khan, Ikram Ullah
    Iqbal, Muhammad Shahid
    Shah, Pervaiz A.
    Khalid, Ikrima
    Gohar, Umar Farooq
    Hussain, Abdullah, I
    Saleem, Muhammad
    Ashraf, Umar
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2020, 19 (11) : 2415 - 2424
  • [25] Development and Validation of a Stability-Indicating RP-HPLC Method for Determination of Atomoxetine Hydrochloride in Tablets
    Patel, Sejal K.
    Patel, Natvarlal J.
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1207 - 1214
  • [26] Development and validation of a stability-indicating RP-HPLC method for the determination of fifteen impurities in rivaroxaban
    Rao, Wanbing
    Li, Lijun
    Zhang, Chenxia
    Zheng, Jinfu
    Fan, Xiaomei
    Luan, Baolei
    Sun, Jiaxiang
    Qiu, Meiyan
    Wu, Shuming
    Li, Yanhua
    Wang, Zhongqing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 228
  • [27] Development and Validation of a Stability-indicating RP-HPLC Method for the Determination of Rivaroxaban in Pharmaceutical Formulations
    Walter, Mauricio E.
    Perobelli, Rafaela F.
    Da Silva, Francielle S.
    Cardoso Junior, Clovis D. A.
    da Silva, Iorhann S.
    Dalmora, Sergio L.
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (08): : 1503 - 1510
  • [28] Validated Stability-indicating RP-HPLC Method for the Determination of Parecoxib Sodium and Degradation Impurities in Bulk Drug
    Yu, Qiuyang
    Yu, Qiuli
    Wu, Lei
    Sun, Jing
    Ma, Panqin
    Liu, Xiaojie
    Dong, Wenxiang
    Zhang, Peng
    CURRENT PHARMACEUTICAL ANALYSIS, 2017, 13 (03) : 271 - 278
  • [29] A Validated Specific Stability-Indicating RP-HPLC Assay Method for the Determination of Loteprednol Etabonate in Eye Drops
    Han, Yong K.
    Segall, Adriana I.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (05) : 761 - 766
  • [30] ESI-MSn and LC-ESI-MS studies to characterize forced degradation products of bosentan and a validated stability-indicating LC-UV method
    Bansal, Gulshan
    Singh, Ranjit
    Saini, Balraj
    Bansal, Yogita
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 72 : 186 - 197