Systematic Design of the Lead-Lag Network Method for Active Damping in LCL-Filter Based Three Phase Converters

被引:200
|
作者
Pena-Alzola, Rafael [1 ]
Liserre, Marco [1 ]
Blaabjerg, Frede [1 ]
Sebastian, Rafael [2 ]
Dannehl, Jorg [3 ]
Fuchs, Friedrich Wilhelm [4 ]
机构
[1] Aalborg Univ, Dept Energy Technol, DK-9220 Aalborg, Denmark
[2] Natl Univ Distance Learning, UNED, Dept Elect Elect & Control Engn, Madrid 28040, Spain
[3] Danfoss Solar Inverters AS, DK-6400 Sonderborg, Denmark
[4] Univ Kiel, Inst Power Elect & Elect Drives, D-24143 Kiel, Germany
关键词
Active damping; lead-lag; LCL-filter; rectifier; stability; voltage-source converter; VOLTAGE-SOURCE CONVERTERS;
D O I
10.1109/TII.2013.2263506
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Three-phase active rectifiers guarantee sinusoidal input currents and unity power factor at the price of a high switching frequency ripple. To adopt an LCL-filter, instead of an L-filter, allows using reduced values for the inductances and so preserving dynamics. However, stability problems can arise in the current control loop if the present resonance is not properly damped. Passive damping simply adds resistors in series with the LCL-filter capacitors. This simplicity is at the expense of increased losses and encumbrances. Active damping modifies the control algorithm to attain stability without using dissipative elements but, sometimes, needing additional sensors. This solution has been addressed in many publications. The lead-lag network method is one of the first reported procedures and continues being in use. However, neither there is a direct tuning procedure (without trial and error) nor its rationale has been explained. Thus, in this paper a straightforward procedure is developed to tune the lead-lag network with the help of software tools. The rationale of this procedure, based on the capacitor current feedback, is elucidated. Stability is studied by means of the root locus analysis in z-plane. Selecting the lead-lag network for the maximum damping in the closed-loop poles uses a simple optimization algorithm. The robustness against the grid inductance variation is also analyzed. Simulations and experiments confirm the validity of the proposed design flow.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [41] New Design Approach for Grid-Current-Based Active Damping of LCL Filter Resonance in Grid-Connected Converters
    Gaafar, Mahmoud A.
    Dousoky, Gamal M.
    Ahmed, Emad M.
    Shoyama, Masahito
    Orabi, Mohamed
    [J]. JOURNAL OF POWER ELECTRONICS, 2018, 18 (04) : 1165 - 1177
  • [42] LCL-Filter Design for Grid-Connected Three-Phase Inverter Using Space Vector PWM
    Seo, SeungGyu
    Cho, Yongsoo
    Lee, Kyo-Beum
    [J]. 2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016, : 389 - 394
  • [43] A Robust Resonance Damping of LCL-filter Based Grid-Connected Converter with Linear Active Disturbance Rejection Control
    Saleem, Muhammad
    Kim, Rae-Young
    [J]. TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 1913 - 1918
  • [44] Design Algorithm of Grid-side LCL-filter for Three-phase Voltage Source PWM Rectifier
    Tong, Yibin
    Tang, Fen
    Chen, Yao
    Zhou, Fei
    Jin, Xinmin
    [J]. 2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 810 - 815
  • [45] Simple sensorless active damping solution for three-phase PWM rectifier with LCL filter
    Malinowski, M
    Kazmierkowski, MP
    Szczygiel, W
    Bernet, S
    [J]. IECON 2005: THIRTY-FIRST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, 2005, : 987 - 991
  • [46] New simple active damping of resonance in three-phase PWM converter with LCL filter
    Malinowski, Mariusz
    Kazmierkowski, Marian P.
    Bernet, Steffen
    [J]. 2005 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY - (ICIT), VOLS 1 AND 2, 2005, : 925 - 929
  • [47] Active Damping of LCL Filter without Capacitor Voltage Sensors for Three Phase PWM Inverter
    An, Byoung-Woong
    Kim, Hag-Wone
    Cho, Kwan-Yuhl
    Han, Byung-Moon
    Chung, Gyo-Bum
    [J]. 39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 7129 - 7133
  • [48] Whale Optimization Algorithm for Active Damping of LCL-Filter-Based Grid-Connected Converters
    Hato, Mohammed Mazen
    Bouallegue, Soufiene
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2019, 9 (02): : 986 - 996
  • [49] Design of PI Controller Together With Active Damping for Grid-Tied LCL-Filter Systems Using Disturbance-Observer-Based Control Approach
    Errouissi, Rachid
    Al-Durra, Ahmed
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (04) : 3820 - 3831
  • [50] New Active Damping Method for LCL Filter Resonance Based on Two Feedback System
    Gaafar, Mahmoud A.
    Dousoky, Gamal M.
    Shoyama, Masahito
    [J]. APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 2735 - 2741