Amperometric detection of phenolic compounds by polypyrrole-based composite carbon paste electrodes

被引:29
|
作者
Mailley, P
Cummings, EA
Mailley, S
Cosnier, S
Eggins, BR
McAdams, E
机构
[1] Univ Grenoble 1, CNRS, CEA, UMR 5819,CREAB Grp,Lab Struct & Proprietes Archit, F-38041 Grenoble 9, France
[2] Univ Ulster, NIBEC, Newtownabbey BT37 0QB, Antrim, North Ireland
[3] Univ Grenoble 1, CNRS, Inst Chim Mol, CNRS,UMR 5630,Lab Electrochim Organ & Photochim R, F-38041 Grenoble 9, France
关键词
carbon paste electrodes; polypyrrole; enzymatic biosensors; polyphenol oxidase; flavonols;
D O I
10.1016/j.bioelechem.2003.11.008
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This contribution describes new composite carbon paste electrodes (CPEs) for the determination of phenolic compounds. The composite CPEs were prepared by in situ generation of polypyrrole (PPy) within a paste containing the enzyme polyphenol oxidase (PPO). The best paste composition (enzyme/pyrrole monomer/carbon particlesNujol) was determined for a model enzyme, glucose oxidase (GOx) according to the enzymatic activity of the resulting electrodes and to the enzyme leakage from the paste during storage in phosphate buffer. The in situ electrogenerated PPy improves the enzyme immobilisation within the paste since practically no enzyme was lost in solution after 72 It of immersion. Moreover, the enzyme activity remains particularly stable under storage since the biocomposite structure conserves 80% of its activity after I month of storage. Following the optimisation of the paste composition, PPO-based carbon paste biosensors were prepared and presented excellent analytical properties toward catechol detection with a sensitivity of 4.7 A M-1 cm(-2) and a response time lower than 20 s. The resulting biosensors were applied to the determination of polyphenolic compounds (e.g., epicatechin and ferulic acid). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [41] Detection of vitamin b1 (thiamine) using modified carbon paste electrodes with polypyrrole
    Muppariqoh, N. M.
    Wahyuni, W. T.
    Putra, B. R.
    3RD INTERNATIONAL SEMINAR ON SCIENCES SCIENCES ON PRECISION AND SUSTAINABLE AGRICULTURE (ISS-2016), 2017, 58
  • [42] Preparation of carbon paste electrode containing polyaniline-activated carbon composite for amperometric detection of phenol
    Arslan, H.
    Senarslan, D.
    Cevrimli, B. S.
    Zengin, H.
    Uzun, D.
    Arslan, F.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2018, 50 (01): : 16 - 20
  • [43] CHEMICALLY MODIFIED CARBON PASTE AND CARBON COMPOSITE ELECTRODES
    STARA, V
    KOPANICA, M
    ELECTROANALYSIS, 1989, 1 (03) : 251 - 256
  • [44] Asymmetric supercapacitors based on carbon nanofibre and polypyrrole/nanocellulose composite electrodes
    Tammela, Petter
    Wang, Zhaohui
    Frykstrand, Sara
    Zhang, Peng
    Sintorn, Ida-Maria
    Nyholm, Leif
    Stromme, Maria
    RSC ADVANCES, 2015, 5 (21): : 16405 - 16413
  • [45] A comparison of amperometric screen-printed, carbon electrodes and their application to the analysis of phenolic compounds present in beers
    Cummings, EA
    Linquette-Mailley, S
    Mailley, P
    Cosnier, S
    Eggins, BR
    McAdams, ET
    TALANTA, 2001, 55 (05) : 1015 - 1027
  • [46] Amperometric cholinesterase biosensors with carbon paste electrodes modified with cobalt phthalocyanine
    Shaidarova, LG
    Ziganshina, SA
    Medyantseva, EP
    Budnikov, GK
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 2004, 77 (02) : 241 - 248
  • [47] Laccase-based screen printed electrode for amperometric detection of phenolic compounds
    Freire, RS
    Duran, N
    Wang, J
    Kubota, LT
    ANALYTICAL LETTERS, 2002, 35 (01) : 29 - 38
  • [48] Development and properties of a polypyrrole-based electrochemical biosensor for cholesterol detection
    Zhang, Xiu-Hua
    Wan, Kai
    Liang, Zhen-Xing
    Jin, Feng
    Piao, Jin-Hua
    Modern Food Science and Technology, 2015, 31 (04) : 170 - 174
  • [49] Amperometric immunosensor for ricin by using on graphite and carbon nanotube paste electrodes
    Suresh, S.
    Gupta, A. K.
    Rao, V. K.
    Kumar, Om
    Vijayaraghavan, R.
    TALANTA, 2010, 81 (1-2) : 703 - 708
  • [50] Amperometric Cholinesterase Biosensors with Carbon Paste Electrodes Modified with Cobalt Phthalocyanine
    L. G. Shaidarova
    S. A. Ziganshina
    E. P. Medyantseva
    G. K. Budnikov
    Russian Journal of Applied Chemistry, 2004, 77 : 241 - 248