Speed control of boiler feed water pump turbine based on gray correlation compensation

被引:1
|
作者
Zhou, Yunlong [1 ]
Wang, Di [1 ]
Zhou, Haichun [2 ]
机构
[1] Northeast Dianli Univ, Sch Energy & Power Engn, Jilin 132012, Jilin, Peoples R China
[2] Northeast Dianli Univ, Sch Automat Engn, Jilin 132012, Jilin, Peoples R China
关键词
Boiler feed water pump turbine (BFPT); Gray correlation degree; Compensation control; Drum water level; Simulation; PREDICTIVE CONTROL; DRUM LEVEL; MODEL;
D O I
10.1007/s12206-016-1246-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
One of the most important controlled parameters of thermal power units is the boiler drum water level. Disturbances of feed water flow rate could cause instability of the drum water level. This study proposes the Gray correlation compensation (GCC) control technology for the Boiler feed water pump turbine (BFPT) to solve this problem. Simulation results indicate that the GCC controller outperforms the traditional proportional-integral-derivative controller when it encounters different disturbances. Furthermore, the GCC controller can rapidly switch to the high-pressure steam source to ensure that the drum water level is in the secure range during steam source switching of the BFPT.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 50 条
  • [41] Analysis and Referential Significance of a Breakdown Accident of the Main Feed Water Pump in a 350 MW Supercritical CFB Boiler
    Deng, Boyu
    Zhang, Man
    Wei, Guohua
    Lyu, Junfu
    Yang, Hairui
    JOURNAL OF THERMAL SCIENCE, 2023, 32 (05) : 1797 - 1806
  • [42] Optimized pump speed control using pump water flow station for HVAC systems
    Liu, Guopeng
    Liu, Mingsheng
    Wang, Gang
    ASHRAE TRANSACTIONS 2007 VOL 113, PT 2, 2007, 113 : 362 - 367
  • [43] LIFE DIAGNOSTIC SYSTEM FOR BOILER FEED WATER PUMP SHAFT IN FOSSIL-FUEL POWER-PLANTS
    HAYASHI, M
    UEYAMA, Y
    HASHIMOTO, Y
    MATERIALS EVALUATION, 1992, 50 (05) : 616 - 621
  • [44] Analysis and Referential Significance of a Breakdown Accident of the Main Feed Water Pump in a 350 MW Supercritical CFB Boiler
    Boyu Deng
    Man Zhang
    Guohua Wei
    Junfu Lyu
    Hairui Yang
    Journal of Thermal Science, 2023, 32 : 1797 - 1806
  • [45] Analysis and Referential Significance of a Breakdown Accident of the Main Feed Water Pump in a 350 MW Supercritical CFB Boiler
    DENG Boyu
    ZHANG Man
    WEI Guohua
    LYU Junfu
    YANG Hairui
    Journal of Thermal Science, 2023, 32 (05) : 1797 - 1806
  • [46] Feed-water control optimization of once-through boiler based on multi-sensor information fusion
    Institute for Thermal Power Engineering, Shandong Electric Power Research Institute, Jinan 250002, China
    不详
    不详
    Dongli Gongcheng, 2008, 5 (735-738): : 735 - 738
  • [47] Performance Evaluation and MPPT Control of a Variable-Speed Pump-as-Turbine System
    Esmaeilian, Hamid Reza
    Fadaeinedjad, Roohollah
    Bakhshai, Alireza
    IEEE SYSTEMS JOURNAL, 2023, 17 (02): : 3117 - 3126
  • [48] Power frequency control of a pump turbine as an example for the operation with adjustable speed of hydraulic machines
    Harbort, T
    Lein, G
    Goede, E
    CONTROL OF POWER SYSTEMS AND POWER PLANTS 1997 (CPSPP'97), 1998, : 335 - 341
  • [49] Backstepping-based Nonlinear Adaptive Control for Boiler-turbine Units
    Fang, Fang
    Wei, Le
    2010 CHINESE CONTROL AND DECISION CONFERENCE, VOLS 1-5, 2010, : 4139 - +
  • [50] Gain scheduled proportional integral control of a model based boiler turbine system
    Kashyap, G. Sairam
    Sant, Amit Vilas
    Yadav, Abhishek
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 (P13) : 7028 - 7034