How many measurements are needed for liver stiffness assessment by 2D-Shear Wave Elastography (2D-SWE) and which value should be used: the mean or median?

被引:0
|
作者
Sporea, Ioan [1 ]
Gradinaru-Tascau, Oana [1 ]
Bota, Simona [1 ]
Popescu, Alina [1 ]
Sirli, Roxana [1 ]
Jurchis, Ana [1 ]
Popescu, Madalina [1 ]
Danila, Mirela [1 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisoara, Romania
关键词
liver stiffness; Shear Wave Elastography; Transient Elastography; ACOUSTIC RADIATION FORCE; CHRONIC HEPATITIS-C; TRANSIENT ELASTOGRAPHY; FIBROSIS ASSESSMENT; ARFI ELASTOGRAPHY; EFSUMB GUIDELINES; CLINICAL-USE; IMPULSE; RECOMMENDATIONS; ACCURACY;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To analyze how many measurements are needed for non-invasive assessment of liver stiffness (LS) by means of 2D-Shear Wave Elastography (2D-SWE) and if the use of mean of median values of 2D-SWE measurements is needed. Methods: We evaluated 449 consecutive subjects (with or without chronic liver disease) by means of Transient Elastography (TE) and 2D-SWE. We compared the correlation of LS assessed by TE with 2D-SWE measurements when using either the median of 5 valid 2D-SWE measurements or the mean of 3 or 5 valid 2D-SWE measurements. Results: We obtained reliable LS measurements by TE in 330/449 subjects (73.5%). From these, in 281 subjects we obtained 5 valid 2D-SWE measurements. The correlation of LS assessed by TE with 2D-SWE values was similar when we used the median value of 5 valid 2D-SWE measurements, the mean value of 5 valid 2D-SWE measurements or the mean value of 3 valid 2D-SWE measurements: r=0.683, r=0.711 and r=0.691, respectively. There were no significant differences between the median value of 5 valid 2D-SWE measurements; the mean value of 5 valid 2D-SWE measurements; or the mean value of 3 valid 2D-SWE measurements: 7.6 kPa, 7.7 kPa and 7.6 kPa, respectively. Conclusions: Our study showed that it is enough to perform 3 valid 2D-SWE measurements and to use the mean value of these measurements.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [21] Comparison of liver stiffness measurements by a 2D-shear wave technique and transient elastography: results from a European prospective multi-centre study
    Ronot, Maxime
    Ferraioli, Giovanna
    Mueller, Hans-Peter
    Friedrich-Rust, Mireen
    Filice, Carlo
    Vilgrain, Valerie
    Cosgrove, David
    Lim, Adrian K.
    [J]. EUROPEAN RADIOLOGY, 2021, 31 (03) : 1578 - 1587
  • [22] 2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis
    Osman, Ahmed M.
    El Shimy, Ahmed
    Abd El Aziz, Mohamed M.
    [J]. INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [23] 2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis
    Ahmed M. Osman
    Ahmed El Shimy
    Mohamed M. Abd El Aziz
    [J]. Insights into Imaging, 11
  • [24] Comparing 2D-shear wave to transient elastography for the evaluation of liver fibrosis in nonalcoholic fatty liver disease
    Karagiannakis, Dimitrios S.
    Markakis, George
    Lakiotaki, Dimitra
    Cholongitas, Evangelos
    Vlachogiannakos, Jiannis
    Papatheodoridis, George
    [J]. EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2022, 34 (09) : 961 - 966
  • [25] Non-invasive staging of liver fibrosis by two-dimensional shear wave elastography (2D-SWE) in patients with chronic hepatitis C and B
    Ahmed M. Alsowey
    Samar M. Shehata
    [J]. Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [26] Assessment of the skin with 2D-shear wave elastography in the systemic scleroderma and its correlation with pulmonary involvement
    Tanyeri, Ahmet
    cildag, Mehmet Burak
    [J]. JOURNAL OF CLINICAL ULTRASOUND, 2023, 51 (07) : 1205 - 1211
  • [27] Diagnostic Accuracy of 2D-Shear Wave Elastography for Liver Fibrosis Severity: A Meta-Analysis
    Jiang, Tian'an
    Tian, Guo
    Zhao, Qiyu
    Kong, Dexing
    Cheng, Chao
    Zhong, Liyun
    Li, Lanjuan
    [J]. PLOS ONE, 2016, 11 (06):
  • [28] Liver Stiffness Measurements by 2D Shear-Wave Elastography: Effect of Steatosis on Fibrosis Evaluation
    Kumada, Takashi
    Toyoda, Hidenori
    Yasuda, Satoshi
    Ogawa, Sadanobu
    Gotoh, Tatsuya
    Ito, Takanori
    Tada, Toshifumi
    Tanaka, Junko
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) : 604 - 612
  • [29] ASSESSING LIVER STIFFNESS BY 2-D SHEAR WAVE ELASTOGRAPHY IN A HEALTHY COHORT
    Bende, Felix
    Mulabecirovic, Anesa
    Sporea, Ioan
    Popescu, Alina
    Sirli, Roxana
    Gilja, Odd Helge
    Vesterhus, Mette
    Havre, Roald Flesland
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (02): : 332 - 341
  • [30] Non-invasive staging of liver fibrosis by two-dimensional shear wave elastography (2D-SWE) in patients with chronic hepatitis C and B
    Alsowey, Ahmed M.
    Shehata, Samar M.
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):