An Evaluation of the Activated Partial Thromboplastin Time Waveform

被引:19
|
作者
Matsumoto, Takeshi [1 ]
Wada, Hideo [2 ]
Fujimoto, Naoki [2 ]
Toyoda, Junki [2 ]
Abe, Yasunori [2 ]
Ohishi, Kohshi [1 ]
Yamashita, Yoshiki [3 ]
Ikejiri, Makoto [4 ]
Hasegawa, Kei [4 ,5 ]
Suzuki, Kei [5 ]
Imai, Hiroshi
Nakatani, Kaname [4 ]
Katayama, Naoyuki [3 ]
机构
[1] Mie Univ, Grad Sch Med, Blood Transfus Serv, Tsu, Mie, Japan
[2] Mie Univ, Grad Sch Med, Dept Mol & Lab Med, Tsu, Mie 5148507, Japan
[3] Mie Univ, Grad Sch Med, Dept Hematol & Oncol, Tsu, Mie, Japan
[4] Mie Univ, Grad Sch Med, Cent Lab, Tsu, Mie, Japan
[5] Mie Univ, Grad Sch Med, Emergency Crit Care Ctr, Tsu, Mie, Japan
关键词
APTT; waveform; biphasic waveform; hemophilia; anticoagulant; DISSEMINATED INTRAVASCULAR COAGULATION; HEMOPHILIA-A; APTT; DIAGNOSIS; MANAGEMENT; THROMBOSIS; DISORDERS; ANALYZER;
D O I
10.1177/1076029617724230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The activated partial thromboplastin time (APTT) waveform includes several parameters that are related to various underlying diseases. The APTT waveform was examined in various diseases. Regarding the pattern of APTT waveform, a biphasic pattern of the first or second derivative curve (DC) was observed in patients with hemophilia and patients positive for antiphospholipid (aPL) antibodies or coagulation factor VIII (FVIII) inhibitors. The time of the first and second DC and fibrin formation at 1/2 height were prolonged in patients with hemophilia, patients with inhibitors, patients positive for aPL, patients treated with anti-Xa agents, and patients with disseminated intravascular coagulation (DIC). These values all tended to decrease in pregnant women (at 28-36 weeks' gestation). The height of the second derivative peak 1 was significantly lower in patients with hemophilia, patients with FVIII inhibitors, patients positive for aPL, patients treated with anti-Xa agents, and patients with DIC; these values tended to be significantly higher in pregnant women. The height of the first DC was significantly lower in patients who were positive for FVIII inhibitors and was significantly higher in patients treated with anti-Xa agents and pregnant women. The height of the first and second DC was useful for the analysis of hemophilia, FVIII inhibitor, and aPL.
引用
收藏
页码:764 / 770
页数:7
相关论文
共 50 条
  • [21] ERRONEOUS ACTIVATED PARTIAL THROMBOPLASTIN TIME
    OWEN, J
    PAYNE, E
    CARSTAIRS, K
    [J]. ANNALS OF INTERNAL MEDICINE, 1978, 89 (01) : 146 - 146
  • [22] Correlation of whole blood activated partial thromboplastin time and plasma activated partial thromboplastin time in haemodialysis patients
    Low, CL
    Eisele, G
    Bailie, GR
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (12) : 2523 - 2523
  • [23] Activated partial thromboplastin time waveform changes and markers of infammation, coagulation and infection in the critically ill
    Howes, D
    Lord, JA
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (12) : A100 - A100
  • [24] Diagnostic efficacy of activated partial thromboplastin time waveform and procalcitonin analysis in pediatric meningococcal sepsis
    Paize, Fauzia
    Carrol, Enitan
    Downey, Colin
    Parry, Christopher M.
    Green, Gerwyn
    Diggle, Peter
    Newland, Paul
    Riordan, F. A. I.
    Thomson, Alistair
    Hart, C. A.
    Toh, Cheng-Hock
    [J]. PEDIATRIC CRITICAL CARE MEDICINE, 2011, 12 (06) : E322 - E329
  • [25] Differences in the Composition of Activated Partial Thromboplastin Time (APTT) Reagents Affect Clot Waveform Analysis
    Kato, Konami
    Hatayama, Yuki
    Shimohiro, Hisashi
    Ichikawa, Hitomi
    Fukuda, Tetsuya
    [J]. YONAGO ACTA MEDICA, 2022, 65 (03) : 226 - 230
  • [26] Activated partial thromboplastin time waveform analysis as specific sepsis marker in cardiopulmonary bypass surgery
    Schneider, Christian P.
    Angele, Martin K.
    Hartl, Wolfgang H.
    [J]. CRITICAL CARE, 2010, 14 (01):
  • [27] Activated partial thromboplastin time waveform analysis as specific sepsis marker in cardiopulmonary bypass surgery
    Christian P Schneider
    Martin K Angele
    Wolfgang H Hartl
    [J]. Critical Care, 14
  • [28] Evaluation of a new synthetic reagent for activated partial thromboplastin time (APTT)
    TouimiBenjelloun, Y
    Corazza, F
    Demulder, A
    Fondu, P
    [J]. THROMBOSIS AND HAEMOSTASIS, 1997, : 791 - 792
  • [29] DIFFERENCES IN THE COMPOSITION OF ACTIVATED PARTIAL THROMBOPLASTIN TIME (APTT) REAGENTS AFFECT CLOT WAVEFORM ANALYSIS
    Kato, Konami
    Hatayama, Yuki
    Shimohiro, Hisashi
    Ichikawa, Hitomi
    Fukuda, Tetsuya
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 81 - 82
  • [30] The activated partial thromboplastin time-clot waveform analysis in hemophilia: Does it help in differentiation?
    Mannan, Khalid Abdul
    Kumar, Narender
    Ahluwalia, Jasmina
    Hans, Chander
    Kler, Anita
    Prakash, Gaurav
    Jain, Richa
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 (02) : 241 - 249