A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE

被引:0
|
作者
Huang, X. [1 ]
Li, S. [2 ]
Schultz, J. [3 ]
Wang, Q. [2 ]
Lin, Q. [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Univ South Carolina, Chem & Biochem Dept, Columbia, SC USA
[3] Univ Calif, Bioengineering Dept, Riverside, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a MEMS sensor for continuous glucose monitoring for diabetes management. The device consists of a microcantilever, which is driven by remote magnetic field and situated in a microchamber separated from the sensing environment by a semi-permeable membrane. As glucose concentration varies, viscosity changes induced by glucose/copolymer binding in a poly(acrylamide-ran-3-acrylamidophenylboronic acid) (PAA-ran-PAAPBA) copolymer solution produce a measurable change in cantilever vibration. The device has been used to measure physiologically relevant glucose concentrations from 0 to 324 mg/dL. The response time of the sensor to glucose concentration changes was 3 minutes and can be further improved with optimized device designs.
引用
收藏
页码:352 / 355
页数:4
相关论文
共 50 条
  • [31] Glucose prediction from continuous subcutaneous monitoring data
    Maran, A
    Sparacino, G
    Pavanini, A
    Crepaldi, C
    Poscia, A
    Tiengo, A
    Avogaro, A
    Cobelli, C
    DIABETES, 2004, 53 : A105 - A105
  • [32] Role of continuous subcutaneous glucose monitoring in intensive care
    Marics, Gabor
    Koncz, Levente
    Korner, Anna
    Mikos, Borbala
    Toth-Heyn, Peter
    ORVOSI HETILAP, 2013, 154 (27) : 1043 - 1048
  • [33] Subcutaneous continuous glucose monitoring in severe burn patients
    Klonoff, David C.
    CRITICAL CARE MEDICINE, 2007, 35 (05) : 1445 - 1445
  • [35] Continuous Glucose Monitoring in Subcutaneous Tissue Using Factory-Calibrated Sensors: A Pilot Study
    Hoss, Udo
    Jeddi, Iman
    Schulz, Mark
    Budiman, Erwin
    Bhogal, Claire
    McGarraugh, Geoffrey
    DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (08) : 591 - 597
  • [36] Interstitial glucose concentration and glycemia: implications for continuous subcutaneous glucose monitoring
    Aussedat, B
    Dupire-Angel, M
    Gifford, R
    Klein, JC
    Wilson, GS
    Reach, G
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (04): : E716 - E728
  • [37] Modification of the sensitivity of glucose sensor implanted into subcutaneous tissue
    ThomeDuret, V
    Gangnerau, MN
    Zhang, Y
    Wilson, GS
    Reach, G
    DIABETES & METABOLISM, 1996, 22 (03): : 174 - 178
  • [38] Nocturnal differences in subcutaneous tissue glucose between forearm and abdominal sites during continuous glucose monitoring in normal subjects
    von Dobeln, A
    Adamson, U
    Lins, PE
    DIABETES & METABOLISM, 2005, 31 (04) : 347 - 352
  • [39] Accuracy of Subcutaneous Continuous Glucose Monitoring in Critically Ill Adults: Improved Sensor Performance with Enhanced Calibrations
    Leelarathna, Lalantha
    English, Shane W.
    Thabit, Hood
    Caldwell, Karen
    Allen, Janet M.
    Kumareswaran, Kavita
    Wilinska, Malgorzata E.
    Nodale, Marianna
    Haidar, Ahmad
    Evans, Mark L.
    Burnstein, Rowan
    Hovorka, Roman
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (02) : 97 - 101
  • [40] Clinical performance of a low cost near infrared sensor for continuous glucose monitoring applied with subcutaneous microdialysis
    Ben Mohammadi, Lhoucine
    Klotzbuecher, T.
    Sigloch, S.
    Welzel, K.
    Goeddel, M.
    Pieber, T. R.
    Schaupp, L.
    BIOMEDICAL MICRODEVICES, 2015, 17 (04)