A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE

被引:0
|
作者
Huang, X. [1 ]
Li, S. [2 ]
Schultz, J. [3 ]
Wang, Q. [2 ]
Lin, Q. [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Univ South Carolina, Chem & Biochem Dept, Columbia, SC USA
[3] Univ Calif, Bioengineering Dept, Riverside, CA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a MEMS sensor for continuous glucose monitoring for diabetes management. The device consists of a microcantilever, which is driven by remote magnetic field and situated in a microchamber separated from the sensing environment by a semi-permeable membrane. As glucose concentration varies, viscosity changes induced by glucose/copolymer binding in a poly(acrylamide-ran-3-acrylamidophenylboronic acid) (PAA-ran-PAAPBA) copolymer solution produce a measurable change in cantilever vibration. The device has been used to measure physiologically relevant glucose concentrations from 0 to 324 mg/dL. The response time of the sensor to glucose concentration changes was 3 minutes and can be further improved with optimized device designs.
引用
收藏
页码:352 / 355
页数:4
相关论文
共 50 条
  • [1] A MEMS viscometric sensor for continuous glucose monitoring
    Zhao, Yongjun
    Li, Siqi
    Davidson, Arthur
    Yang, Bozhi
    Wang, Qian
    Lin, Qiao
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (12) : 2528 - 2537
  • [2] A Biocompatible Affinity MEMS Sensor for Continuous Monitoring of Glucose
    Huang, Xian
    Li, Siqi
    Schultz, Jerome
    Wang, Qian
    Lin, Qiao
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 797 - +
  • [3] A MEMS DIFFERENTIAL DIELECTRIC SENSOR FOR CONTINUOUS GLUCOSE MONITORING
    Huang, X.
    LeDuc, C.
    Ravussin, Y.
    Li, S.
    Song, B.
    Wang, Q.
    Accili, D.
    Leibel, R.
    Lin, Q.
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [4] Miniaturized fiber-optic hybrid sensor for continuous glucose monitoring in subcutaneous tissue
    Pasic, Alen
    Koehler, Hans
    Klimant, Ingo
    Schaupp, Lukas
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 60 - 68
  • [5] Continuous glucose monitoring on the ICU using a subcutaneous sensor
    Punke, M. A.
    Decker, C.
    Wodack, K.
    Reuter, D. A.
    Kluge, S.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (05) : 360 - 363
  • [6] Application of MEMS Based Capacitive Sensor for Continuous Monitoring of Glucose
    Samyuktha, Nagesh
    Maneesha, Pattanshetti
    Sreelakshmi, B. R.
    Pattnaik, P. K.
    Narayan, K.
    TENCON 2015 - 2015 IEEE REGION 10 CONFERENCE, 2015,
  • [7] A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring
    Huang, Xian
    Li, Siqi
    Davis, Erin
    Leduc, Charles
    Ravussin, Yann
    Cai, Haogang
    Song, Bing
    Li, Dachao
    Accili, Domenico
    Leibel, Rudolph
    Wang, Qian
    Lin, Qiao
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2013, 23 (05)
  • [8] TOWARDS CONTINUOUS GLUCOSE MONITORING - INVIVO EVALUATION OF A MINIATURIZED GLUCOSE SENSOR IMPLANTED FOR SEVERAL DAYS IN RAT SUBCUTANEOUS TISSUE
    MOATTISIRAT, D
    CAPRON, E
    POITOUT, V
    REACH, G
    BINDRA, DS
    ZHANG, Y
    WILSON, GS
    THEVENOT, DR
    DIABETOLOGIA, 1992, 35 (03) : 224 - 230
  • [9] CONTINUOUS GLUCOSE MONITORING IN SUBCUTANEOUS TISSUE AND BLOOD WITH AN AMPEROMETRIC ENZYME ELECTRODE
    BRUCKEL, J
    ZIER, H
    KERNER, W
    PFEIFFER, EF
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 89 - 91
  • [10] Feasibility of Continuous Ketone Monitoring in Subcutaneous Tissue Using a Ketone Sensor
    Alva, Shridhara
    Castorino, Kristin
    Cho, Hyun
    Ou, Junli
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (04): : 768 - 774