Fast determination of regional myocardial strain fields from tagged cardiac images using harmonic phase MRI

被引:194
|
作者
Garot, J
Bluemke, DA
Osman, NF
Rochitte, CE
McVeigh, ER
Zerhouni, EA
Prince, JL
Lima, JAC
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[5] Johns Hopkins Univ, Whiting Sch Engn, Baltimore, MD 21218 USA
关键词
magnetic resonance imaging; ventricles; myocardium; contractility;
D O I
10.1161/01.CIR.101.9.981
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Tagged MRI of the heart is difficult to implement clinically because of the lack of fast analytical techniques. We investigated the accuracy of harmonic phase (HARP) imaging for rapid quantification of myocardial strains and for detailed analysis of left ventricular (LV) function during dobutamine stimulation. Methods and Results-Tagged MRI was performed in 10 volunteers at rest and during 5 to 20 mu g(-1) . kg(-1) . min(-1) dobutamine and in 9 postinfarct patients at rest. We compared 2D myocardial strains (circumferential shortening, Ecc; maximal shortening, E-2; and E-2, direction) as assessed by a conventional technique and by HARP. Full quantitative analysis of the data was 10 times faster with HARP. For pooled data, the regression coefficient was r=0.93 for each strain (P<0.001). In volunteers, Ecc and E-2 were greater in the free wall than in the septum (P<0.01), but recruitable myocardial strain at peak dobutamine was greater in the LV septum (P<0.01). E-2 orientation shifted away from the circumferential direction at peak dobutamine (P<0.01). HARP accurately detected subtle changes in myocardial strain fields under increasing doses of dobutamine. In patients, HARP-determined Ecc and E-2 values were dramatically reduced in the asynergic segments as compared with remote (P<0.001), and E-2 direction shifted away from the circumferential direction (P<0.001). Conclusions-HARP MRI provides fast, accurate assessment of myocardial strains from tagged MR images in normal subjects and in patients with coronary artery disease with wall motion abnormalities. HARP correctly indexes dobutamine-induced changes in strains and has the potential for on-line quantitative monitoring of LV function during stress testing.
引用
收藏
页码:981 / 988
页数:8
相关论文
共 50 条
  • [21] Quantitative assessment of regional myocardial function in a rat model of myocardial infarction using tagged MRI
    D. Thomas
    V.A. Ferrari
    M. Janik
    D.H. Kim
    S. Pickup
    J.D. Glickson
    R. Zhou
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2004, 17 : 179 - 187
  • [22] Quantitative assessment of regional myocardial function in a rat model of myocardial infarction using tagged MRI
    Thomas, D
    Ferrari, VA
    Janik, M
    Kim, DH
    Pickup, S
    Glickson, JD
    Zhou, R
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (3-6) : 179 - 187
  • [23] Three-Dimensional Plus Time Biventricular Strain from Tagged MR Images by Phase-Unwrapped Harmonic Phase
    Venkatesh, Bharath Ambale
    Schiros, Chun G.
    Gupta, Himanshu
    Lloyd, Steven G.
    Dell'Italia, Louis
    Denney, Thomas S., Jr.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) : 799 - 810
  • [24] Tag Removal in Cardiac Tagged MRI Images using Coupled Dictionary Learning
    Makram, Abram W.
    Rushdi, Muhammad A.
    Khalifa, Ayman M.
    El-Wakad, Mohamed T.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7921 - 7924
  • [25] Evaluation of a phase-based motion tracking method for the calculation of myocardial stress and strain from tagged MRI
    Lennart Tautz
    Anja Hennemuth
    Teodora Chitiboi
    Ulrich Kramer
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [26] Measuring tongue motion from tagged cine-MRI using harmonic phase (HARP) processing
    Parthasarathy, Vijay
    Prince, Jerry L.
    Stone, Maureen
    Murano, Erni Z.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 121 (01): : 491 - 504
  • [27] 3D myocardial strain strain reconstruction from tagged MRI using a cylindrical B-spline model
    Deng, XA
    Denney, TS
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 609 - 612
  • [28] Determination of Cardiac Wall Deformations from MRI Images
    Sciammarella, Cesar Augusto
    Lamberti, Luciano
    Boccaccio, Antonio
    MECHANICS OF BIOLOGICAL SYSTEMS AND MATER IALS, VOL 6, 2016, : 69 - 83
  • [29] Regional assessment of LV wall in infarcted heart using tagged MRI and cardiac modelling
    Jahanzad, Zeinab
    Liew, Yih Miin
    Bilgen, Mehmet
    McLaughlin, Robert A.
    Leong, Chen Onn
    Chee, Kok Han
    Aziz, Yang Faridah Abdul
    Ung, Ngie Min
    Lai, Khin Wee
    Ng, Siew-Cheok
    Lim, Einly
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (10): : 4015 - 4031
  • [30] Artifacts reduction in strain maps of tagged magnetic resonance imaging using harmonic phase
    Wang, Daolei
    Fu, YaBo
    Ashraf, Muhammad Aqeel
    OPEN MEDICINE, 2015, 10 (01): : 425 - 433