Inter-laboratory ring trials to evaluate serological methods for dourine diagnosis

被引:5
|
作者
Cauchard, Julien [1 ]
Soldan, Andrew [2 ]
Madeline, Anthony [1 ]
Johnson, Paula [2 ]
Buscher, Philippe [3 ]
Petry, Sandrine [1 ]
机构
[1] ANSES, Dozule Lab Equine Dis, Bacteriol & Parasitol Unit, Goustranville, France
[2] Anim Hlth & Vet Labs Agcy, Qual Assurance Unit, Loughborough, Leics, England
[3] Inst Trop Med, Dept Biomed Sci, B-2000 Antwerp, Belgium
关键词
Dourine; Surra; Ring trial; Serology; Trypanosoma equiperdum; Trypanosoma evansi; TRYPANOSOMA-EQUIPERDUM; INFECTED HORSES; T-EQUIPERDUM; EVANSI; TESTS;
D O I
10.1016/j.vetpar.2014.06.025
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
To evaluate the reproducibility of routine serological methods to detect Trypanosoma equiperdum antibodies in equine sera, two inter-laboratory ring trials were organized involving 22 European and 4 non-European reference laboratories for dourine. The serological methods were the complement fixation test (CFT; 25 laboratories) and the indirect fluorescent antibody test (IFAT; 4 laboratories). Three of the laboratories applied both these methods. The sample panels were composed of sera that were negative, positive or suspected for dourine. Of the negative sera, one was from a donkey naturally infected with Trypanosoma evansi. This study confirmed the reliability of CFT and highlighted its inter-laboratory reproducibility for known T. equiperdum positive and negative sera. However the reproducibility was less good for sera positive for T. evansi or of unknown status, e.i. nine out of 22 laboratories observed a false-positive result with the T. evansi-positive serum, whether by CFT or IFAT. This interesting result suggests that the specificity of dourine serodiagnosis may be improved by standardizing the critical reagents, including antigens and by developing a standard T. equiperdum serum which could be used calibrate test systems across multiple laboratories. Trial data confirmed seropositivity in one of the three horses suspected of dourine. It may be beneficial to generalize the use of a suitable low-titer serum control, derived from a standard serum in order to standardize the method's detection limit. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
  • [41] INTER-LABORATORY TRIALS OF THE EPR METHOD FOR THE DETECTION OF IRRADIATED MEATS CONTAINING BONE
    DESROSIERS, MF
    LE, FG
    MCLAUGHLIN, WL
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 1994, 29 (02): : 153 - 159
  • [42] PLANNING INTER-LABORATORY TRIALS AND DATA-PROCESSING IN THE CREATION OF STANDARD SPECIMENS
    LONTSIKH, SV
    BERKOVITS, LA
    PARSHIN, AK
    MEASUREMENT TECHNIQUES USSR, 1981, 24 (08): : 671 - 674
  • [43] Inter-laboratory trials for analysis of perfluorooctanesulfonate and perfluorooctanoate in water samples: Performance and recommendations
    Taniyasu, Sachi
    Kannan, Kurunthachalam
    Wu, Qian
    Kwok, Karen Y.
    Yeung, Leo W. Y.
    Lam, Paul K. S.
    Chittim, Brock
    Kida, Takafumi
    Takasuga, Takumi
    Tsuchiya, Yoshiteru
    Yamashita, Nobuyoshi
    ANALYTICA CHIMICA ACTA, 2013, 770 : 111 - 120
  • [44] International inter-laboratory trials to determine the factors affecting the measurement of chocolate viscosity
    Aeschlimann, JM
    Beckett, ST
    JOURNAL OF TEXTURE STUDIES, 2000, 31 (05) : 541 - 576
  • [45] ROBUST STATISTICS - HOW NOT TO REJECT OUTLIERS .2. INTER-LABORATORY TRIALS
    不详
    ANALYST, 1989, 114 (12) : 1699 - 1702
  • [46] METHODS FOR THE DETECTION OF THERMOTOLERANT CAMPYLOBACTERS IN FOODS - RESULTS OF AN INTER-LABORATORY STUDY
    SCOTTER, SL
    HUMPHREY, TJ
    HENLEY, A
    JOURNAL OF APPLIED BACTERIOLOGY, 1993, 74 (02): : 155 - 163
  • [47] Using Bayes methods and mixture models in inter-laboratory studies with outliers
    Garritt L. Page
    Stephen B. Vardeman
    Accreditation and Quality Assurance, 2010, 15 : 379 - 389
  • [48] Wheat varietal identification by capillary electrophoresis: An inter-laboratory comparison of methods
    Bietz, JA
    Lookhart, GL
    FOOD SCIENCE AND TECHNOLOGY-LEBENSMITTEL-WISSENSCHAFT & TECHNOLOGIE, 1997, 30 (02): : 210 - 213
  • [49] INTER-LABORATORY EVALUATION OF AMINOTRANSFERASE ASSAYS - THE SCANDINAVIAN COMMISSION ON ENZYMES METHODS
    GOLDBERG, DM
    LUSTIG, V
    CLINICAL BIOCHEMISTRY, 1985, 18 (03) : 204 - 204
  • [50] FURTHER INTERNATIONAL INTER-LABORATORY TRIALS IN YIELD-TESTING AND A SUMMARY OF RESULTS
    DAVID, HG
    JOURNAL OF THE TEXTILE INSTITUTE, 1975, 66 (04) : 144 - 146