Comparison of renal dynamic imaging and two plasma sample method in determining glomerular filtration rate in patients with diabetic nephropathy

被引:0
|
作者
Li, Ming-Hao [1 ]
Jiang, Nan [1 ]
机构
[1] Yanbian Univ Hosp China, Dept Nucl Med, 1327 Ju Zi St, Yanji 133000, Jilin, Peoples R China
关键词
Renal dynamic imaging; two plasma sample (TPS) method; glomerular filtration rate; diabetic nephropathy; CHRONIC KIDNEY-DISEASE; CHINESE PATIENTS; SCINTIGRAPHY; CLEARANCE; EQUATION;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: This study aims to compare the application significance of renal dynamic imaging (RDI) and two plasma sample (TPS) method in determining glomerular filtration rate (GFR) in patients with diabetic nephropathy. Methods: A total of 68 patients who received medical service in the Endocrinology Department of our hospital were enrolled into this study. These patients were divided into three groups: early nephropathy group (DN1 group, n=23), clinical nephropathy group (DN2 group, n=23) and uremia group (DN3 group, n=22). In addition, 22 healthy subjects were enrolled and assigned as control group (DN0 group). GFRs of all subjects were determined by both RDI and TPS method, and the correlation between results and determination methods were analyzed. Results: GFRs (gGFRs and tGFRs) in the DN0, DN1 and DN2 groups were determined by RDI and TPS, and the difference was not statistically significant (P> 0.05). Differences between gGFR and tGFR in the DN3 group was statistically significant (P< 0.05). Correlation coefficients between GFRs determined by RDI and TPS in the DN0, DN1, DN2 and DN3 groups were 0.999, 0.947, 0.925 and 0.999, respectively. All values exhibited a significant positive correlation (P< 0.05). Conclusions: Both RDI and TPS can sensitively reveal GFR changes in early and clinical nephropathy. However, RDI revealed poor accuracy and low sensitivity in the diagnosis of diabetic nephropathy in the uremic phase, and medical history combined with other examination methods should be applied in the diagnosis.
引用
下载
收藏
页码:19919 / 19924
页数:6
相关论文
共 50 条
  • [31] Comparison of Different Estimating Equations for Glomerular Filtration Rate in Type 2 Diabetic Patients
    Chen, Xuanrong
    Wang, Manman
    Zeng, Longyi
    DIABETES, 2013, 62 : A144 - A144
  • [32] IN-111DTPA - RADIOPHARMACEUTICAL FOR DYNAMIC RENAL IMAGING AND MEASUREMENT OF GLOMERULAR FILTRATION-RATE
    FARRER, PA
    SAHA, GB
    JOURNAL OF NUCLEAR MEDICINE, 1973, 14 (06) : 394 - 394
  • [33] Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods
    Chowdhury, TA
    Dyer, PH
    Bartlett, WA
    Legge, ES
    Durbin, SM
    Barnett, AH
    Bain, SC
    CLINICA CHIMICA ACTA, 1998, 277 (02) : 153 - 158
  • [34] Comparison of glomerular filtration rate measurements with the two plasma sample and single plasma sample, gamma camera Gates, creatinine clearance, and prediction equation methods in potential kidney donors with normal renal function
    Aydin, Funda
    Gungor, Firat
    Cengiz, Arzu Kin
    Tuncer, Murat
    Mahsereci, Erkan
    Ozdem, Sadi
    Cenkci, Mehmet
    Karayalcin, Binnur
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (02) : 157 - 165
  • [35] Extended measurement of glomerular filtration rate and effective renal plasma flow in ambulatory patients
    Svarstad, E
    Iversen, BM
    Ofstad, J
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1995, 29 (04): : 375 - 382
  • [36] Comparison for glomerular filtration rate in gamma camera systems using dynamic renal phantom system
    Kang, Chun Goo
    Park, Hoon-Hee
    Oh, Shin Hyun
    Lee, Han Wool
    Kim, Jung Yul
    Oh, Joo Young
    Lee, Juyoung
    Kim, Jae Sam
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [37] Comparison for glomerular filtration rate in gamma camera systems using dynamic renal phantom system
    Kang, Chun Goo
    Park, Hoon-Hee
    Oh, Shin Hyun
    Lee, Han Wool
    Kim, Jung Yul
    Oh, Joo Young
    Lee, Juyoung
    Kim, Jae Sam
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [38] Albuminuria and reduced glomerular filtration rate for predicting the renal outcomes in type 2 diabetic patients
    Tanaka, Nobue
    Babazono, Tetsuya
    Takagi, Michino
    Yoshida, Naoshi
    Toya, Kiwako
    Nyumura, Izumi
    Hanai, Ko
    Uchigata, Yasuko
    NEPHROLOGY, 2015, 20 (08) : 531 - 538
  • [39] Longitudinal Changes in Measured Glomerular Filtration Rate, Renal Fibrosis and Biomarkers in a Rat Model of Type 2 Diabetic Nephropathy
    Su, Zhi
    Widomski, Deborah
    Ma, Ji
    Namovic, Marian
    Nikkel, Arthur
    Leys, Laura
    Olson, Lauren
    Salte, Katherine
    Donnelly-Roberts, Diana
    Esbenshade, Timothy
    McGaraughty, Steve
    AMERICAN JOURNAL OF NEPHROLOGY, 2016, 44 (05) : 339 - 353
  • [40] Glomerular filtration rate in type 1 diabetic adolescent by using single plasma sample and gamma camera methods
    Aras, Feray
    Bilgin, Elvan Sayit
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2021, 12 (04): : 362 - 366