M-mode ultrasound: a reliable measure of transversus abdominis thickness?

被引:82
|
作者
Bunce, SM [1 ]
Moore, AP [1 ]
Hough, AD [1 ]
机构
[1] Clin Res Ctr Hlth Prof, Eastbourne BN20 7UR, England
关键词
ultrasound; abdominal muscle; transversus abdominis;
D O I
10.1016/S0268-0033(02)00011-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this study was to establish a reliable method for measuring transversus abdominis thickness in asymptomatic human subjects in supine lying, standing and walking. Design and methods. This was a single operator reliability study using ultrasound imaging to measure 22 subjects oil three separate occasions. A purpose built high-density foam reinforced belt was used to house and position the transducer over the midpoint of the transversus abdominis. Each subject was imaged in supine, standing, and treadmill walking at 3 kph. Intraclass correlation coefficients and standard error of measurement analysis were used to measure the data. Results. The correlation coefficient data analysis resulted in intraclass correlation coefficients of 0.94 (standard error of measurement 0.35) in supine lying, 0.88 (0.66) in standing and 0.88 (0.56) in walking. Conclusion. The method described is a reliable tool for measuring changes in thickness of transversus abdominis in supine lying, standing and walking.
引用
收藏
页码:315 / 317
页数:3
相关论文
共 50 条
  • [31] TEMPORAL CHANGES IN PORCINE VALVE THICKNESS MEASURED BY M-MODE ECHOCARDIOGRAPHY
    ALAM, M
    GOLDSTEIN, S
    LAKIER, JB
    CIRCULATION, 1980, 62 (04) : 34 - 34
  • [32] Extended field-of-view ultrasound imaging is reliable for measuring Transversus Abdominis muscle size at rest and during contraction
    A. Wayne Johnson
    Lauren Adams
    Jade B. Kho
    Daniel M. Green
    Nicolas B. Pace
    Ulrike H. Mitchell
    BMC Musculoskeletal Disorders, 22
  • [33] Extended field-of-view ultrasound imaging is reliable for measuring Transversus Abdominis muscle size at rest and during contraction
    Johnson, A. Wayne
    Adams, Lauren
    Kho, Jade B.
    Green, Daniel M.
    Pace, Nicolas B.
    Mitchell, Ulrike H.
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [34] Separate assessment of gluteus medius and minimus: B-mode or M-mode ultrasound?
    Dieterich, Angela V.
    Deshon, Louise
    Pickard, Christine M.
    Strauss, Geoffrey R.
    McKay, Janice
    PHYSIOTHERAPY THEORY AND PRACTICE, 2014, 30 (06) : 438 - 443
  • [35] Effects of posture on the thickness of transversus abdominis in pain-free subjects
    Reeve, Angelica
    Dilley, Andrew
    MANUAL THERAPY, 2009, 14 (06) : 679 - 684
  • [36] Measurement of Pectoralis Major Deformation during Activities with M-Mode Ultrasound
    Ying, Zhang
    Wang Zehua
    Chi, Zhang
    Yang, Yang
    Simha, Narendra. K.
    Li Deyu
    PROCEEDINGS OF 2013 IEEE INTERNATIONAL CONFERENCE ON MEDICAL IMAGING PHYSICS AND ENGINEERING (ICMIPE), 2013, : 196 - 200
  • [37] A Correction Method for Muscle Stiffness Sensors to Measure Transversus Abdominis Activity
    Nakamae, Shunsuke
    Tanaka, Takayuki
    Shimatani, Koji
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2023, 35 (03) : 810 - 822
  • [38] Estimating Wrist Joint Angle Based on M-Mode Ultrasound Signals
    Li, Jianmin
    Song, Yingzhuo
    Zhu, Kun
    Pan, Lizhi
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2024, 9 (09): : 8130 - 8137
  • [39] Assessment of intramuscular activation patterns using ultrasound M-mode strain
    Lindberg, F.
    Ohberg, F.
    Brodin, L. A.
    Gronlund, C.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2013, 23 (04) : 879 - 885
  • [40] M-mode ultrasound imaging of tongue movement during swallowing.
    Peng, CL
    Lin, CT
    Yeh, WC
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 766 - 766