M-mode ultrasound: a reliable measure of transversus abdominis thickness?

被引:82
|
作者
Bunce, SM [1 ]
Moore, AP [1 ]
Hough, AD [1 ]
机构
[1] Clin Res Ctr Hlth Prof, Eastbourne BN20 7UR, England
关键词
ultrasound; abdominal muscle; transversus abdominis;
D O I
10.1016/S0268-0033(02)00011-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The purpose of this study was to establish a reliable method for measuring transversus abdominis thickness in asymptomatic human subjects in supine lying, standing and walking. Design and methods. This was a single operator reliability study using ultrasound imaging to measure 22 subjects oil three separate occasions. A purpose built high-density foam reinforced belt was used to house and position the transducer over the midpoint of the transversus abdominis. Each subject was imaged in supine, standing, and treadmill walking at 3 kph. Intraclass correlation coefficients and standard error of measurement analysis were used to measure the data. Results. The correlation coefficient data analysis resulted in intraclass correlation coefficients of 0.94 (standard error of measurement 0.35) in supine lying, 0.88 (0.66) in standing and 0.88 (0.56) in walking. Conclusion. The method described is a reliable tool for measuring changes in thickness of transversus abdominis in supine lying, standing and walking.
引用
收藏
页码:315 / 317
页数:3
相关论文
共 50 条
  • [1] A Reliable M-Mode Ultrasound Protocol for the Assessment of Diaphragm Motion
    Parreira, Filipe
    Machado, Rui
    Tomas, Teresa
    Ribeiro, Ricardo
    CHEST, 2014, 145 (03)
  • [2] Using ultrasound to assess the thickness of the transversus abdominis in a sling exercise
    Jörn Lükens
    Kim J. Boström
    Christian Puta
    Tobias L. Schulte
    Heiko Wagner
    BMC Musculoskeletal Disorders, 16
  • [3] CHANGE IN MUSCLE THICKNESS OF THE REGIONS OF TRANSVERSUS ABDOMINIS BY ULTRASOUND IMAGING
    Mori, Natsuko
    Ikezoe, Tome
    Ichihashi, Noriaki
    JAPANESE JOURNAL OF PHYSICAL FITNESS AND SPORTS MEDICINE, 2011, 60 (03) : 319 - 326
  • [4] Using ultrasound to assess the thickness of the transversus abdominis in a sling exercise
    Luekens, Joern
    Bostroem, Kim J.
    Puta, Christian
    Schulte, Tobias L.
    Wagner, Heiko
    BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [5] M-MODE ULTRASOUND IN HAND TREMORS
    Titianova, E.
    Dimova, R.
    Koleva, Z.
    Karazapryanov, P.
    INTERNATIONAL JOURNAL OF STROKE, 2017, 12 : 19 - 19
  • [6] Ultrasound imaging for transversus abdominis blocks
    Walter, E. J.
    Smith, P.
    Albertyn, R.
    Uncles, D. R.
    ANAESTHESIA, 2008, 63 (02) : 211 - 211
  • [7] Tissue Deformation Index as a Reliable Measure of Lateral Abdominal Muscle Activation on M-Mode Sonography
    Bialy, Maciej
    Adamczyk, Waclaw
    Gnat, Rafael
    Stranc, Tomasz
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (07) : 1461 - 1467
  • [8] LUMINAL CHANGES AND WALL THICKNESS IN THE OVINE ESOPHAGUS - CORRELATION BETWEEN ENDOSCOPY AND M-MODE ULTRASOUND
    TANIGUCHI, DK
    MARTIN, R
    TROWERS, E
    ODEGAARD, S
    SILVERSTEIN, F
    GASTROENTEROLOGY, 1993, 104 (04) : A590 - A590
  • [9] Measurement of abdominal muscle thickness using M-mode ultrasound imaging during functional activities
    Bunce, SM
    Hough, AD
    Moore, AP
    MANUAL THERAPY, 2004, 9 (01) : 41 - 44
  • [10] Is there an underestimation of intima-media thickness based on M-mode ultrasound technique in the abdominal aorta?
    Dahlen, Elsa M.
    Andreasson, Thomas
    Cinthio, Magnus
    Nystrom, Fredrik H.
    Ostgren, Carl Johan
    Lanne, Toste
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2012, 32 (01) : 1 - 4