Pragmatic image reconstruction for the MiCES fully-3D mouse imaging PET scanner

被引:0
|
作者
Lee, KS
Kinahan, PE
Fessler, JA
Miyaoka, RS
Lewellen, TK
机构
关键词
D O I
10.1109/NSSMIC.2003.1352414
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a pragmatic approach to image reconstruction for data from the MiCES fully-3D mouse imaging PET scanner under construction at the University of Washington. Our approach is modeled on fully-3D image reconstruction used in clinical PET scanners, which is based on Fourier rebinning (FORE) followed by 2D iterative image reconstruction. The use of iterative methods allows modeling the effects of statistical noise and attenuation etc., while FORE accelerates the reconstruction process by reducing the fully-3D data to a stacked set of independent 2D sinograms. Preliminary investigations have indicated that non-stationary detector point-spread response effects, which are ignored for clinical imaging, significantly impact image quality for the MiCES scanner geometry. To model the effect of non-stationary detector point spread response, we have added a factorized system matrix to the ASPIRE reconstruction library. The current implementation uses FORE+AWOSEM followed by post-reconstruction 3D Gaussian smoothing. The results indicate that the proposed approach produces a dramatic improvement in resolution without undue increases in noise.
引用
收藏
页码:2566 / 2570
页数:5
相关论文
共 50 条
  • [1] Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner
    Lee, K
    Kinahan, PE
    Fessler, JA
    Miyaoka, RS
    Janes, M
    Lewellen, TK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (19): : 4563 - 4578
  • [2] Fully-3D PET reconstruction from raw LOR histograms.
    Kadrmas, DJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 163P - 163P
  • [3] Fully-3D PET Image Reconstruction Using Scanner-Independent, Adaptive Projection Data and Highly Rotation-Symmetric Voxel Assemblies
    Scheins, J. J.
    Herzog, H.
    Shah, N. J.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 879 - 892
  • [4] An LOR-based fully-3D PET image reconstruction using a blob-basis function
    Hu, Z.
    Wang, W.
    Gualtieri, E. E.
    Hsieh, Y. L.
    Karp, J. S.
    Matej, S.
    Parma, A. J.
    Tung, C. H.
    Walsh, E. S.
    Werner, M.
    Gagnon, D.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4415 - +
  • [5] Experimental comparison of lesion detectability for four fully-3D PET reconstruction schemes
    Kadrmas, Dan J.
    Casey, Michael E.
    Black, Noel F.
    Hamill, James J.
    Panin, Vladimir Y.
    Conti, Maurizio
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2817 - +
  • [6] Correction Technique for Cascade Gammas in I-124 Imaging on a Fully-3D, Time-of-Flight PET Scanner
    Surti, Suleman
    Scheuermann, Ryan
    Karp, Joel S.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 653 - 660
  • [7] Experimental Comparison of Lesion Detectability for Four Fully-3D PET Reconstruction Schemes
    Kadrmas, Dan J.
    Casey, Michael E.
    Black, Noel F.
    Hamill, James J.
    Panin, Vladimir Y.
    Conti, Maurizio
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (04) : 523 - 534
  • [8] Content-adaptive mesh modeling for fully-3D tomographic image reconstruction
    Yang, YY
    Brankov, JG
    Wernick, MN
    [J]. 2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2002, : 621 - 624
  • [9] A FULLY 3D SMALL PET SCANNER
    TAVERNIER, S
    BRUYNDONCKX, P
    SHUPING, Z
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 635 - 643
  • [10] Noise characteristics of the FORE plus OSEM(DB) reconstruction method for the MiCES PET scanner
    Lee, K
    Kinahan, PE
    Miyaoka, RS
    Fessler, JA
    Lewellen, TK
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2642 - 2646