Experimental comparison of lesion detectability for four fully-3D PET reconstruction schemes

被引:0
|
作者
Kadrmas, Dan J. [1 ]
Casey, Michael E. [1 ]
Black, Noel F. [1 ]
Hamill, James J. [1 ]
Panin, Vladimir Y. [1 ]
Conti, Maurizio [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, 729 Arapeen Dr, Salt Lake City, UT 84108 USA
关键词
D O I
10.1109/NSSMIC.2007.4436724
中图分类号
O59 [应用物理学];
学科分类号
摘要
The objective of this work was to evaluate the lesion detectability performance of four fully-3D PET reconstruction schemes using experimentally acquired data. A multi-compartment anthropomorphic phantom was setup to mimic whole-body FDG cancer imaging and scanned twelve times in 3D mode. Eight of the scans had twenty-six Ge-68 "shell-less" lesions (6, 8, 10, 12, 16 mm diam.) placed throughout the phantom with various target:background ratios. This provided lesion-present and lesion-absent datasets with known truth appropriate for evaluating lesion detectability by localization receiver operating characteristics (LROC) methods. Four reconstruction schemes were studied: (1) Fourier rebinning (FORE) followed by 2D attenuation-weighted ordered-subsets expectation-maximization; (2) fully-3D AW-OSEM; (3) fully-3D ordinary-Poisson line-of-response (LOR-)OSEM; and (4) fully-3D LOR-OSEM with an accurate point-spread function (PSF) model. Two forms of LROC analysis were performed. First, a channelized non-prewhitened (CNPW) observer was used to optimize processing parameters (number of iterations, post-reconstruction filter) for the human observer study. Human observers then rated each image and selected the most-likely lesion location. The area under the LROC curve (A(LROC)) and the probability of correct localization were used as figures-of-merit. The results of the human observer study found no statistically significant difference between FORE and AW-OSEM3D) (A(LROC)=0.41 and 0.36, respectively), an increase in lesion detection performance for LOR-OSEM3D (A(LROC)=0.45, p=0.076), and additional improvement with the use of the PSF model (A(LROC)=0.55, p=0.024). The numerical CNPW observer provided the same rankings in performance among algorithms, but obtained different values of ALROC. These results show improved lesion detection performance for the reconstruction algorithms with more sophisticated statistical and imaging models as compared to the previous-generation algorithms.
引用
收藏
页码:2817 / +
页数:3
相关论文
共 50 条
  • [1] Experimental Comparison of Lesion Detectability for Four Fully-3D PET Reconstruction Schemes
    Kadrmas, Dan J.
    Casey, Michael E.
    Black, Noel F.
    Hamill, James J.
    Panin, Vladimir Y.
    Conti, Maurizio
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (04) : 523 - 534
  • [2] Fully-3D PET reconstruction from raw LOR histograms.
    Kadrmas, DJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 163P - 163P
  • [3] Pragmatic image reconstruction for the MiCES fully-3D mouse imaging PET scanner
    Lee, KS
    Kinahan, PE
    Fessler, JA
    Miyaoka, RS
    Lewellen, TK
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2566 - 2570
  • [4] An LOR-based fully-3D PET image reconstruction using a blob-basis function
    Hu, Z.
    Wang, W.
    Gualtieri, E. E.
    Hsieh, Y. L.
    Karp, J. S.
    Matej, S.
    Parma, A. J.
    Tung, C. H.
    Walsh, E. S.
    Werner, M.
    Gagnon, D.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4415 - +
  • [5] Content-adaptive mesh modeling for fully-3D tomographic image reconstruction
    Yang, YY
    Brankov, JG
    Wernick, MN
    [J]. 2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL II, PROCEEDINGS, 2002, : 621 - 624
  • [6] Phantom and methodology for comparison of small lesion detectability in PET
    Wollenweber, Scott D.
    Alessio, Adam M.
    Kinahan, Paul E.
    [J]. MEDICAL PHYSICS, 2023, 50 (05) : 2998 - 3007
  • [7] Fully 3D GPU PET reconstruction
    Herraiz, J. L.
    Espana, S.
    Cal-Gonzalez, J.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S169 - S171
  • [8] Improving lesion detectability in PET imaging with a penalized likelihood reconstruction algorithm
    Wangerin, Kristen A.
    Ahn, Sangtae
    Ross, Steven G.
    Kinahan, Paul E.
    Manjeshwar, Ravindra M.
    [J]. MEDICAL IMAGING 2015: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2015, 9416
  • [9] QUASI-3D AND FULLY-3D MODELING OF SUSPENDED SEDIMENT TRANSPORT
    TORO, FM
    MEIJER, K
    VANRIJN, L
    [J]. SEDIMENT TRANSPORT MODELING: PROCEEDINGS OF AN INTERNATIONAL SYMPOSIUM, 1989, : 45 - 51
  • [10] Fully-3D PET Image Reconstruction Using Scanner-Independent, Adaptive Projection Data and Highly Rotation-Symmetric Voxel Assemblies
    Scheins, J. J.
    Herzog, H.
    Shah, N. J.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 879 - 892