Signal and data processing of wavemeter with Michelson interferometer

被引:0
|
作者
Wang Liqiang [1 ]
Ren Wenjie [2 ,3 ]
机构
[1] Beijing Univ Posts & Telecommun, Elect Engn Sch, Beijing 100876, Peoples R China
[2] Dalian Univ Technol, Civil & Hydraul Sch, Dalian 116024, Peoples R China
[3] Hebei Univ Technol, Civil Engn Sch, Tianjin 300132, Peoples R China
关键词
optoelectronic conversion; cut-off frequency; PLL; locking range; counter; MCU; 8254 programmable timer;
D O I
10.1117/12.693650
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laser wavemeter with a Michelson interferometer is a high-precision instrument. The signal and data processing is so important to this wavemeter. It includes an optoelectronic conversion module, an amplifying and comparator circuit, a PLL unit, a counter, serial communications between the MCU and the computer. S1223 photodiodes are selected as the detectors. PLL unit including NE564 and 74LS193 is used to multiply frequency. The timing capacitor, loop gain coefficient, and the locking range of PLL are calculated. The counter is used to measure the number of interference fringes of the reference laser and the number of interference fringes of an unknown laser. Finally, the wavelength of an unknown laser is calculated and displayed on LCD. The signal and data processing of the wavemeter meets its accuracy of seven-bit significant figure.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Computer-controlled high-precision Michelson wavemeter
    J. Pedregosa-Gutierrez
    D. Guyomarc’h
    M. Vedel
    C. Champenois
    M. Knoop
    The European Physical Journal Plus, 129
  • [22] Analog processing based vibration measurement technique using michelson interferometer
    Hussain B.
    Ahmed M.
    Hussain G.
    Saleem M.
    Nawaz M.
    Hussain, B. (babarhussain2002@hotmail.com), 2013, Springer Verlag (03) : 137 - 143
  • [23] Broadband squeezing of quantum noise in a Michelson interferometer with Twin-Signal-Recycling
    Thuering, Andre
    Graef, Christian
    Vahlbruch, Henning
    Mehmet, Moritz
    Danzmann, Karsten
    Schnabel, Roman
    OPTICS LETTERS, 2009, 34 (06) : 824 - 826
  • [24] Detection method of nonlinearity errors by statistical signal analysis in heterodyne Michelson interferometer
    School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
    不详
    Opt. Express, 6 (5831-5839):
  • [25] Fundamental study for measuring microflow with Michelson interferometer enhanced by external random signal
    Michihata, Masaki
    Dang, Phong Tran
    Hayashi, Terutake
    Takaya, Yasuhiro
    JOURNAL OF ADVANCED MECHANICAL DESIGN SYSTEMS AND MANUFACTURING, 2014, 8 (04):
  • [26] Simple and accurate wavemeter implemented with a polarization interferometer
    Dimmick, TE
    APPLIED OPTICS, 1997, 36 (36): : 9396 - 9401
  • [27] LASER WAVEMETER WITH SOLID FIZEAU WEDGE INTERFEROMETER
    REISER, C
    LOPERT, RB
    APPLIED OPTICS, 1988, 27 (17): : 3656 - 3660
  • [28] Calibration of a Michelson-type laser wavemeter and evaluation of its accuracy
    Hussein, H.
    Sobee, M. A.
    Amer, M.
    OPTICS AND LASERS IN ENGINEERING, 2010, 48 (03) : 393 - 397
  • [29] AUTOMATIC ALIGNMENT OF A MICHELSON INTERFEROMETER
    BARONE, F
    DIFIORE, L
    MILANO, L
    RUSSO, G
    SOLIMENO, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (02) : 232 - 237
  • [30] MICHELSON INTERFEROMETER FOR ASTRONOMICAL APPLICATIONS
    GUIDI, I
    MELCHIORRI, B
    MELCHIORRI, F
    NATALE, V
    INFRARED PHYSICS, 1978, 18 (04): : 267 - 273