Signal and data processing of wavemeter with Michelson interferometer

被引:0
|
作者
Wang Liqiang [1 ]
Ren Wenjie [2 ,3 ]
机构
[1] Beijing Univ Posts & Telecommun, Elect Engn Sch, Beijing 100876, Peoples R China
[2] Dalian Univ Technol, Civil & Hydraul Sch, Dalian 116024, Peoples R China
[3] Hebei Univ Technol, Civil Engn Sch, Tianjin 300132, Peoples R China
关键词
optoelectronic conversion; cut-off frequency; PLL; locking range; counter; MCU; 8254 programmable timer;
D O I
10.1117/12.693650
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Laser wavemeter with a Michelson interferometer is a high-precision instrument. The signal and data processing is so important to this wavemeter. It includes an optoelectronic conversion module, an amplifying and comparator circuit, a PLL unit, a counter, serial communications between the MCU and the computer. S1223 photodiodes are selected as the detectors. PLL unit including NE564 and 74LS193 is used to multiply frequency. The timing capacitor, loop gain coefficient, and the locking range of PLL are calculated. The counter is used to measure the number of interference fringes of the reference laser and the number of interference fringes of an unknown laser. Finally, the wavelength of an unknown laser is calculated and displayed on LCD. The signal and data processing of the wavemeter meets its accuracy of seven-bit significant figure.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Michelson Interferometer Signal Processing Based on Wavelet Transformation
    Lu, Xizhao
    Lin, Zhenheng
    Huang, Yuanqing
    Lin, Zhenheng
    2009 SYMPOSIUM ON PHOTONICS AND OPTOELECTRONICS (SOPO 2009), 2009, : 524 - +
  • [2] Optical path layout and moving mirrors of wavemeter based on michelson interferometer
    Wang Liqiang
    Peng Yuexiang
    Gao Fengyou
    He Yongli
    Zheng Hongxing
    INFRARED MATERIALS, DEVICES, AND APPLICATIONS, 2007, 6835
  • [3] A Compact Signal Processing with Position Sensitive Detectors Utilized for Michelson Interferometer
    Shyu, Lih-Horng
    Wang, Yung-Cheng
    Lin, Jui-Cheng
    MEASUREMENT TECHNOLOGY AND INTELLIGENT INSTRUMENTS IX, 2010, 437 : 98 - +
  • [4] A Sagnac-Michelson fibre optic interferometer: Signal processing for disturbance localization
    Kondrat, M.
    Szustakowski, M.
    Palka, N.
    Ciurapinski, W.
    Zyczkowski, M.
    OPTO-ELECTRONICS REVIEW, 2007, 15 (03) : 127 - 132
  • [5] A PRECISION DRIVE FOR A MICHELSON WAVEMETER
    JAFFEE, SM
    YEN, WM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (06): : 1459 - 1463
  • [6] High accuracy Michelson interference wavemeter
    Wang, LQ
    Li, C
    Song, FJ
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 7, 2005, : 338 - 341
  • [7] Universal Michelson Gires-Tournois interferometer optical interleaver based on digital signal processing
    Zhang, Juan
    Yang, Xiaowei
    OPTICS EXPRESS, 2010, 18 (05): : 5075 - 5088
  • [8] Broadband and tuned signal recycling with a simple Michelson interferometer
    Gray, MB
    Stevenson, AJ
    Bachor, HA
    McClelland, DE
    APPLIED OPTICS, 1998, 37 (25): : 5886 - 5893
  • [9] VERTICAL HIGH-PRECISION MICHELSON WAVEMETER
    MORALES, A
    DEURQUIJO, J
    MENDOZA, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (01): : 76 - 81
  • [10] THE MICHELSON INTERFEROMETER
    GIACOMO, P
    MIKROCHIMICA ACTA, 1987, 3 (1-6) : 19 - 31