A novel active grating monochromator - Active grating spectrometer beamline system for inelastic soft-X-ray scattering experiments

被引:0
|
作者
Fung, HS [1 ]
Chen, CT [1 ]
Huang, LJ [1 ]
Chang, CH [1 ]
Chung, SC [1 ]
Wang, DJ [1 ]
Tseng, TC [1 ]
Tsang, KL [1 ]
机构
[1] Natl Synchrotron Radiat Res Ctr, Hsinchu 30077, Taiwan
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
By using two aspherical variable-line-space active gratings and applying the energy compensation principle, we have designed a very efficient active grating monochromator - active grating spectrometer (AGM-AGS) beamline system for the photon demanding inelastic soft-x-ray scattering experiments. During the energy scan, the defocus and coma aberrations of the AGM can be completely eliminated to make the focal point fixed at the sample position and to maintain high spectral resolution for the entire spectral range. The AGS, which has an optical system identical to that of the AGM, but positioned reversely along the optical path, collects the photons emitted from the sample with a nearly identical energy spread as the AGM and focus them onto a position sensitive detector located at the exit slit position. The ray tracing results show that the efficiency of the AGM-AGS is two orders of magnitudes higher than that of conventional design while maintaining a very high spectral resolution.
引用
收藏
页码:655 / 658
页数:4
相关论文
共 50 条
  • [21] A NOTE ON GRATING BASED SOFT-X-RAY MONOCHROMATORS
    SAHNI, VC
    PRAMANA-JOURNAL OF PHYSICS, 1990, 35 (02): : 187 - 191
  • [22] FABRICATION OF SUPERSMOOTH SPHERICAL QUARTZ BLANK FOR SOFT-X-RAY SYNCHROTRON RADIATION GRATING MONOCHROMATOR IN CHINA
    ZHOU, CX
    SHU, DM
    LIU, WM
    X-RAY/EUV OPTICS FOR ASTRONOMY AND MICROSCOPY, 1989, 1160 : 177 - 185
  • [23] SOFT-X-RAY MONOCHROMATOR WITH A VARIED-SPACE PLANE GRATING FOR SYNCHROTRON RADIATION - DESIGN AND EVALUATION
    ITOU, M
    HARADA, T
    KITA, T
    APPLIED OPTICS, 1989, 28 (01): : 146 - 153
  • [24] Mechanical design and performance evaluation for plane grating monochromator in a soft X-ray microscopy beamline at SSRF
    Gong, Xuepeng
    Lu, Qipeng
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (04) : 409 - 421
  • [25] THE DESIGN AND PERFORMANCE OF A SOFT-X-RAY DOUBLE CRYSTAL MONOCHROMATOR BEAMLINE AT ALADDIN
    YANG, BX
    MIDDLETON, FH
    OLSSON, BG
    BANCROFT, GM
    CHEN, JM
    SHAM, TK
    TAN, K
    WALLACE, DJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 316 (2-3): : 422 - 436
  • [26] Highly efficient beamline and spectrometer for inelastic soft X-ray scattering at high resolution
    Lai, C. H.
    Fung, H. S.
    Wu, W. B.
    Huang, H. Y.
    Fu, H. W.
    Lin, S. W.
    Huang, S. W.
    Chiu, C. C.
    Wang, D. J.
    Huang, L. J.
    Tseng, T. C.
    Chung, S. C.
    Chen, C. T.
    Huang, D. J.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 325 - 332
  • [27] Fabrication of Aberration-corrected Diffraction Grating for Soft X-ray Grating Monochromator
    Hua, Yilei
    Li, Hailiang
    Xie, Changqing
    PHOTOPTICS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PHOTONICS, OPTICS AND LASER TECHNOLOGY, 2019, : 107 - 110
  • [28] SOFT-X-RAY SCATTERING AND DIFFRACTION BY A LAMELLAR MULTILAYER AMPLITUDE GRATING - EXPERIMENT AND THEORY
    SAMMAR, A
    OUAHABI, M
    BARCHEWITZ, R
    ANDRE, JM
    OPTICS COMMUNICATIONS, 1993, 99 (5-6) : 309 - 315
  • [29] Precise measurement technology of soft-x-ray spectrum using dual transmission grating spectrometer
    Yang, JM
    Ding, YN
    Zhang, WH
    Zhang, JY
    Zheng, ZJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (10): : 4268 - 4272
  • [30] From soft to hard X-ray with a single grating monochromator
    Cocco, D.
    Bianco, A.
    Kaulich, B.
    Schaefers, F.
    Mertin, M.
    Reichardt, G.
    Nelles, B.
    Heidemann, K. F.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 497 - +