An amperometric acetone sensor by using an electro-deposited Pb-modified electrode

被引:4
|
作者
Wang, Chia-Chi [1 ]
Weng, Yu-Ching [1 ]
Chou, Tse-Chuan [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Chem Engn, Tainan 701, Taiwan
关键词
acetone; sensor; lead; electrodeposited Pb; amperometry;
D O I
10.1515/znb-2006-0509
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
An amperometric acetone sensor was developed by using an electrodeposited Pb electrode in a sodium tartrate electrolyte. The major factors determining the electrode and sensing characteristics such as the applied potential, electrodeposition current density, electrodeposition temperature, agitation rate, and sensing temperature were explored. The best conditions for preparation of the electrodeposited Pb electrode were obtained at a 30 mA cm(-2) electrodeposition current density and a 30 degrees C electrodeposition temperature. Additionally, the optimal sensing conditions are a 155 rpm agitation rate and 50 degrees C sensing temperature with the applied potential in the range from -2.25 similar to -2.35 V (vs. Ag/AgCl). The results also revealed that the electrodeposited Pb electrode has a good linearity between the response current and the acetone concentration. This type of acetone sensor has excellent selectivity and shows the highest sensitivity at 8 mu Appm(-1) cm(-2).
引用
收藏
页码:560 / 564
页数:5
相关论文
共 50 条
  • [31] Amperometric sensor used for determination of thiocyanate with a silver nanoparticles modified electrode
    Wang, GF
    Li, MG
    Gao, YC
    Fang, B
    SENSORS, 2004, 4 (09): : 147 - 155
  • [32] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yuan, Yawen
    Zheng, Yiqun
    Liu, Jinglei
    Wang, Hua
    Hou, Shifeng
    MICROCHIMICA ACTA, 2017, 184 (12) : 4723 - 4729
  • [33] An amperometric biosensor using Prussian blue modified electrode
    Yi, In-Je
    Kim, Ju-Ho
    Kang, C. J.
    Park, Jaehyun
    Kim, Yong-Sang
    ECO-MATERIALS PROCESSING & DESIGN VII, 2006, 510-511 : 746 - 749
  • [34] Acetone sensor using lead foil as working electrode
    Wang, Chia-Chi
    Weng, Yu-Ching
    Chou, Tse-Chuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (02) : 591 - 595
  • [35] Amperometric DNA sensor using gold electrode modified with polymerized mediator by layer-by-layer adsorption
    Suye, S
    Matsuura, T
    Kimura, T
    Zheng, H
    Hori, T
    Amano, Y
    Katayama, H
    MICROELECTRONIC ENGINEERING, 2005, 81 (2-4) : 441 - 447
  • [36] An Efficient Amperometric Sensor for Hydrogen Peroxide by Using a Carbon Paste Electrode Modified with Cobalt Impregnated Zeolite
    Norouzi, Banafsheh
    Moradian, Majid
    Malekan, Ali
    PORTUGALIAE ELECTROCHIMICA ACTA, 2015, 33 (02) : 111 - 124
  • [37] Amperometric Biomedical Sensor for the Determination of Nitric Oxide Using an Electrochemically Activated and Modified Pencil Graphite Electrode
    Wu, Ying
    Liu, Chao
    Liu, Xiaojun
    Zhu, Chunnan
    Dang, Xueping
    Hu, Shengshui
    Zheng, Dongyun
    ANALYTICAL LETTERS, 2021, 54 (16) : 2537 - 2550
  • [38] BASIC STUDY ON STRESS MEASUREMENT USING SLIP-INITIATION PHENOMENON IN ELECTRO-DEPOSITED IRON
    KITAOKA, S
    NAGASE, Y
    SEIKA, M
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1981, 24 (194): : 1363 - 1371
  • [39] Amperometric sensor for ascorbic acid using a gold electrode modified with ZnO@SiO2 nanospheres
    Khan, Sher Bahadar
    Ahmed, Md Sameer
    Asiri, Abdullah M.
    NEW JOURNAL OF CHEMISTRY, 2016, 40 (10) : 8438 - 8443
  • [40] An amperometric flow injection analysis enzyme sensor for sucrose using a tetracyanoquinodimethane modified graphite paste electrode
    Lima, JL
    Pandey, PC
    Weetall, HH
    BIOSENSORS & BIOELECTRONICS, 1996, 11 (08): : 719 - 723