Using Geant4 Monte Carlo toolkit to evaluate a low power X-ray tube generator configuration

被引:2
|
作者
Hoff, G. [1 ,2 ,5 ]
Streck, E. E. [3 ]
Lai, A. [1 ,2 ]
Fanti, V [1 ,2 ]
Golosio, B. [1 ,2 ]
Nascimento, C. D. [4 ]
Souza, E. G. [4 ]
机构
[1] Univ Cagliari, Phys Dept, Monserrato, Italy
[2] Natl Inst Nucl Phys, Dept Cagliary, Monserrato, Italy
[3] Pontificia Univ Catolica Rio Grande do Sul, Phys Coll, Porto Alegre, RS, Brazil
[4] Univ Catolica Pelotas, Grad Program Comp & Elect Engn, Pelotas, RS, Brazil
[5] Hosp Clin Porto Alegre, Med Phys & Radioprotect Serv, Av Ramiro Barcelos 2350, BR-90035903 Porto Alegre, RS, Brazil
关键词
X-ray generator design; X-ray sources; Transport models; Monte Carlo simulation; SPECTRA; SIMULATION; OPTIMIZATION; MODEL;
D O I
10.1016/j.apradiso.2020.109487
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Monte Carlo technique has been widely used as an important tool to develop new irradiation equipment, prototype medical equipment parts, and test methodologies for dosimetry. In this manuscript, we present a methodology to design a low power X-ray tube generator using the Geant4 Monte Carlo toolkit. The simulations were performed considering a large number of variables, namely, the material composition of the target track, the window thickness, and the air pressure of the X-ray tube. The X-ray production was simulated considering monoenergetic electron beams impinging on targets of tungsten and copper with incident kinetic energies ranging from 20 keV to 60 keV and initial divergences from 5 degrees to 30 degrees. For the polyenergetic emission, a conservative approach with Gaussian energy distribution was adopted. The analysis indicates that among the evaluated parameters, the incident kinetic energy, and the target material produced the most notable changes in the spectra shape and conversion efficiency (CE), significantly impacting the X-ray tube design. The studies provide a reliable methodology to explore general configurations for X-ray tube generators, defining the best geometry, material compositions, and thicknesses to be used on spectroscopy applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] A Geant4-based Monte Carlo X-ray imaging simulation platform
    Li, Ouyi
    Gao, Jianhua
    Zhang, Qiong
    [J]. APPLIED RADIATION AND ISOTOPES, 2024, 210
  • [42] Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study
    Nasseri, Mohammad Mehdi
    [J]. PRAMANA-JOURNAL OF PHYSICS, 2019, 92 (04):
  • [43] Implementation of detector response function modeling for small animal SPECT using Geant4 Monte Carlo Simulation Toolkit
    El Bitar, Ziad
    Brasse, David
    Gullberg, Grant
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [44] Proton Therapy Range Verification Using Prompt Gamma Rays: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [45] Validation of Independent IMRT and VMAT Dose Calculation System based on Geant4 Monte Carlo Toolkit
    Choi, H. J.
    Park, H.
    Shin, W. G.
    Kim, J. I.
    Min, C. H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S942 - S942
  • [46] A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
    Arbor, Nicolas
    Gasteuil, Jean
    Noblet, Caroline
    Moreau, Matthieu
    Meyer, Philippe
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 112 - 117
  • [47] Dosimetric Validation of An Intrabeam™ GATE Model, Based On Monte Carlo GEANT4 Toolkit, for IORT Applications
    Bouzid, D.
    Visvikis, D.
    Dupre, P.
    Bert, J.
    Pradier, O.
    Nicolas, B.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [48] Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study
    Mohammad Mehdi Nasseri
    [J]. Pramana, 2019, 92
  • [49] Development of a Geant4 based Monte Carlo Algorithm to evaluate the MONACO VMAT treatment accuracy
    Fleckenstein, Jens
    Jahnke, Lennart
    Lohr, Frank
    Wenz, Frederik
    Hesser, Juergen
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (01): : 33 - 45
  • [50] Combination of electromagnetic physics processes for microdosimetry in liquid water with the Geant4 Monte Carlo simulation toolkit
    Ivanchenko, V. N.
    Incerti, S.
    Francis, Z.
    Tran, H. N.
    Karamitros, M.
    Bernal, M. A.
    Champion, C.
    Gueye, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 273 : 95 - 97