Feasibility of real-time magnetic resonance-guided stent-graft placement in a swine model of descending aortic dissection

被引:0
|
作者
Eggebrecht, H. [1 ]
Kuehl, H. [1 ]
Aker, S. [1 ]
Breuckmann, F. [1 ]
Zenge, M. [1 ]
Mehta, R. [1 ]
Erbel, R. [1 ]
Quick, H. [1 ]
机构
[1] Duke Univ, Clin Res Inst, Durham, NC 27706 USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:262 / 262
页数:1
相关论文
共 50 条
  • [41] Real-time cardiovascular magnetic resonance-guided radiofrequency ablation: A comprehensive review
    Tampakis, Konstantinos
    Pastromas, Sokratis
    Sykiotis, Alexandros
    Kampanarou, Stamatina
    Kourgiannidis, Georgios
    Pyrpiri, Chrysa
    Bousoula, Maria
    Rozakis, Dimitrios
    Andrikopoulos, George
    WORLD JOURNAL OF CARDIOLOGY, 2023, 15 (09): : 415 - 426
  • [42] Retrograde type A aortic dissections after endovascular stent-graft placement for type B dissection
    Bellos, J. K.
    Petrosyan, A.
    Abdulamit, T.
    Trastour, J. -C.
    Bergeron, P.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2010, 51 (01): : 85 - 93
  • [43] Endovascular stent-graft placement to obliterate the entry tear: A new treatment for acute aortic dissection
    Dake, MD
    Kato, N
    Slonim, SM
    Razavi, MK
    Semba, CP
    Kee, ST
    Sze, DY
    Samuels, SL
    Mitchell, RS
    Miller, DC
    CIRCULATION, 1998, 98 (17) : 67 - 67
  • [44] Endoluminal stent-graft placement for acute dissection of the descending aorta complicated with rupture. Report of one case
    Fava P, Mario
    Espindola, Manuel
    Bertoni, Hernan
    Loyola Z, M. Soledad
    Meneses Q, Luis
    Maureira, Mauricio
    REVISTA MEDICA DE CHILE, 2006, 134 (08) : 1024 - 1029
  • [45] Real-Time Magnetic Resonance Imaging-Guided Transarterial Aortic Valve Implantation In Vivo Evaluation in Swine
    Kahlert, Philipp
    Parohl, Nina
    Albert, Juliane
    Schaefer, Lena
    Reinhardt, Renate
    Kaiser, Gernot M.
    McDougall, Ian
    Decker, Brad
    Plicht, Bjoern
    Erbel, Raimund
    Eggebrecht, Holger
    Ladd, Mark E.
    Quick, Harald H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (02) : 192 - 193
  • [46] Real-time magnetic resonance imaging-guided coronary catheterization in swine
    Omary, RA
    Green, JD
    Schirf, BE
    Li, YZ
    Finn, JP
    Li, DB
    CIRCULATION, 2003, 107 (21) : 2656 - 2659
  • [47] Endovascular stent-graft placement for nonsurgical repair of descending aortic perforations:: Acute and follow-up results
    Scheinert, D
    Schmidt, A
    Scheinert, S
    Bräunlich, S
    Krankenberg, H
    Biamino, G
    Mohr, F
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 470A - 471A
  • [48] Emergent endovascular stent-graft placement to treat ruptured Stanford type B acute aortic dissection
    Kawamura, SK
    Nishimaki, H
    Lin, ZB
    Machii, M
    Isobe, Y
    Hayakawa, K
    Soma, K
    JOURNAL OF VASCULAR SURGERY, 2004, 39 (03) : 668 - 671
  • [49] Endovascular Stent-Graft Placement in Patients with Stanford Type B Aortic Dissection in China: A Systematic Review
    Wang, Junwei
    Li, Yonghui
    Li, Yongxin
    Ren, Zefang
    Chen, Peng
    Qian, Xueke
    Wang, Shenming
    Wang, Jinsong
    ANNALS OF VASCULAR SURGERY, 2016, 36 : 298 - 309
  • [50] Towards real-time cardiovascular magnetic resonance-guided transarterial aortic valve implantation: In vitro evaluation and modification of existing devices
    Philipp Kahlert
    Holger Eggebrecht
    Björn Plicht
    Oliver Kraff
    Ian McDougall
    Brad Decker
    Raimund Erbel
    Mark E Ladd
    Harald H Quick
    Journal of Cardiovascular Magnetic Resonance, 12