Embryo/fetus radiation dose and risk from dual X-ray absorptiometry examinations

被引:32
|
作者
Damilakis, J
Perisinakis, K
Vrahoriti, H
Kontakis, G
Varveris, H
Gourtsoyiannis, N
机构
[1] Univ Crete, Fac Med, Dept Phys Med, Iraklion 71409, Crete, Greece
[2] Univ Crete, Fac Med, Dept Radiotherapy, Iraklion 71409, Crete, Greece
[3] Univ Crete, Fac Med, Dept Radiol, Iraklion 71409, Crete, Greece
[4] Democritus Univ Thrace, Fac Med, Dept Orthopaed, Thrace, Greece
关键词
conceptus; dual X-ray absorptiometry; radiation dose;
D O I
10.1007/s001980200098
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the current study was to estimate the embryo/fetus radiation doses and risks associated with spinal and hip dual X-ray absorptiometry (DXA) scans performed on the pregnant mother. The results were compared with the embryo/fetus dose from a thoracolumbar radiograph and pelvic radiograph. Posteroanterior (PA) lumbar spine and proximal femur scans during the first, second and third trimesters were performed on a phantom simulating pregnancy at the three trimesters of gestation. All scans were carried out using a Hologic 1000/W pencil beam DXA unit. Moreover, embryo/fetus doses from a (a) thoracolumbar radiograph and (b) pelvic radiograph were estimated for all periods of gestation using the same phantom. Radiation doses were measured using thermoluminescent dosimeters. The dose reduction achievable by shielding the embryo/fetus with a protective apron during DXA scans was studied for all trimesters of gestation. The embryo/fetus doses during the first trimester were measured to be 1.7 muGy and 2.7 muGy for the PA spine and femur DXA scan, respectively, for an embryo/fetus located 8.5 cm from the anterior maternal surface. The risk of excess fatal cancer was 0.2 per million unborn children irradiated in utero for measurements of the spine and 0.3 per million unborn children for measurements of the femur. The embryo/fetus doses during the second and third trimesters were 2.7 muGy and 4.9 muGy respectively for the scans of the lumbar spine. The risk of childhood fatal cancer was 0.3 per million for the second trimester and 0.5 per million for the third trimester. The embryo/fetus radiation doses during the second and third trimesters were estimated as 1.4 muGy and 1.0 muGy respectively for the examinations of the proximal femur. The risk of childhood fatal cancer was 0.1 per million for both trimesters. The use of the apron resulted in a very small change in the dose absorbed by the embryo/fetus. The embryo/fetus dose associated with both DXA modes investigated in the current study is at least 700 times lower in comparison with embryo/fetus dose from a thoracolumbar or pelvic radiograph in all periods of gestation. In conclusion, the embryo/fetus dose in bone density measurements of spine and femur using pencil beam DXA is lower than the average daily natural background in the United States of 8 muGy. The health provider can decide whether a DXA scanning is beneficial to a pregnant woman, taking into account the potential radiation risks to the embryo/fetus presented in the current study.
引用
收藏
页码:716 / 722
页数:7
相关论文
共 50 条
  • [31] Dual X-ray Absorptiometry for Diagnosis of Osteoporosis
    Neuner, Joan
    Carnahan, Jennifer
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (11): : 1147 - 1148
  • [32] Single and dual energy X-ray absorptiometry
    Adams, JE
    EUROPEAN RADIOLOGY, 1997, 7 (Suppl 2) : S20 - S31
  • [33] STUDIES ABOUT THE EXPOSURE TO RADIATION OF THE FETUS IN CASE OF X-RAY EXAMINATIONS DURING GRAVIDITY
    FINZEL, GT
    SABEL, M
    WEISHAAR, J
    STRAHLENTHERAPIE, 1981, 157 (12) : 833 - 843
  • [34] Precision assessment and radiation safety for dual-energy X-ray absorptiometry
    Baim, S
    Wilson, CR
    Lewiecki, EM
    Luckey, MM
    Downs, RW
    Lentle, BC
    JOURNAL OF CLINICAL DENSITOMETRY, 2005, 8 (04) : 371 - 378
  • [35] Comparison of Dual X-ray Laser and Dual Energy X-ray Absorptiometry Techniques of Osteodensitometry
    Yumru, A. E.
    Bozkurt, M.
    Aksoy, H. E.
    Coskun, E. Inci
    Ayanoglu, Y. T.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (02) : 541 - 546
  • [36] Evaluation of peripheral dual energy X-ray absorptiometry: comparison with single photon absorptiometry of the forearm and dual energy X-ray absorptiometry of the spine or femur
    Mole, PA
    McMurdo, MET
    Paterson, CR
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (844): : 427 - 432
  • [37] Radiation dose and cancer risk in patients undergoing multiple radiographs in intravenous urography X-ray examinations
    Suliman, I. I.
    Al-Jabri, Amna J.
    Badawi, A. A.
    Halato, M. A.
    Alzimami, K.
    Sulieman, A.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 272 - 275
  • [38] Comparison of calcaneus ultrasound and dual X-ray absorptiometry in children at risk of osteopenia
    Fielding, KT
    Nix, DA
    Bachrach, LK
    JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (01) : 7 - 15
  • [39] PATIENT RADIATION DOSE FROM CHEST X-RAY EXAMINATIONS IN THE WEST BANK-PALESTINE
    Lahham, Adnan
    Issa, Ahlam
    ALMasri, Hussein
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (03) : 298 - 303
  • [40] THE RADIATION-DOSE TO CHILDREN FROM X-RAY EXAMINATIONS OF THE PELVIS AND THE URINARY-TRACT
    ALMEN, A
    MATTSSON, S
    BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (810): : 604 - 613