Pre-use intraoperative testing of autologous tissue for valvular surgery: A proof of concept study

被引:0
|
作者
Hanlon, JG
Suggit, RW
Love, JW
机构
[1] CardioMend LLC, Santa Barbara, CA USA
[2] McLean Engn, Vancouver, BC, Canada
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Autologous tissue is being used more commonly for valvular repair and reconstruction, but methods for testing the mechanical properties of the tissue intraoperatively have not been available. Before committing to its use, the surgeon should know its thickness, strength, and if it is isotropic or anisotropic. We have developed an intraoperative tissue tester (ITT), based on optical and mechanical methods that allows a surgeon to assess these parameters rapidly. Methods: Tissue thickness was measured with a micrometer. Specimens of tissue were incrementally pressurized to 200 mmHg, resulting in a dome-shaped distortion. The dome is a section of a spheroid whose dimensions are determined by the diameter of the circle and the height of the dome. The LaPlace equation for a sphere was used to calculate tissue stress. Moire fringe patterns are visualized as concentric circles or ellipses produced by directing a beam of collimated light at 45 degrees through a grid with Ronchi rulings onto the surface of the dome. Circles indicate isotropy and ellipses indicate anisotropy. Uniaxial testing was performed on strips of tissue taken from orthogonal and intermediate axes to validate Moire fringe pattern analysis. Specimens of human pericardium (n = 8), lightly tanned by a 10-min immersion in buffered 0.625% glutaraldehyde, were examined. Results: Mean thickness of eight specimens was 0.61 mm (range: 0.41-0.99 mm). During inflation, the lightly tanned human pericardium showed non-linear deformation characteristic of pericardium. Mean peak stress for the dome was 136 kPa. There was good correlation between dome height in the inflation tester and the uniaxial Young's modulus. Moire fringe pattern analysis showed minimal anisotropy to 200 mmHg pressure, confirmed by uniaxial testing. Conclusions: The basic mechanical properties of autologous tissue to be used for valvular repair or reconstruction should be determined to avoid use of tissue that is outside an expected range of values for strength, anisotropy/isotropy and thickness. A self-contained ITT, based on optical and mechanical principles, has been developed to measure those parameters.
引用
收藏
页码:614 / 623
页数:10
相关论文
共 50 条
  • [21] Precision image-guided colonic surgery: proof of concept for enhanced preoperative and intraoperative vascular imaging
    Forgione, Antonello
    Barberio, Manuel
    Agnus, Vincent
    Swanstrom, Lee
    Marescaux, Jacques
    Diana, Michele
    Gallix, Benoit
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (02): : 962 - 970
  • [22] Precision image-guided colonic surgery: proof of concept for enhanced preoperative and intraoperative vascular imaging
    Antonello Forgione
    Manuel Barberio
    Vincent Agnus
    Lee Swanström
    Jacques Marescaux
    Michele Diana
    Benoit Gallix
    Surgical Endoscopy, 2021, 35 : 962 - 970
  • [23] Automating the interpretation of cardiopulmonary exercise testing: a proof-of-concept study
    Staes, Michael
    Elmahy, Ahmed
    Styleman, Dimitri
    Verstraete, Kenneth
    Huts, Helene
    Beersaerts, Amber
    Troosters, Thierry
    De Vos, Maarten
    Janssens, Wim
    EUROPEAN RESPIRATORY JOURNAL, 2024, 64
  • [24] Transplantation of an allogeneic vein bioengineered with autologous stem cells: a proof-of-concept study
    Olausson, Michael
    Patil, Pradeep B.
    Kuna, Vijay Kumar
    Chougule, Priti
    Hernandez, Nidia
    Methe, Ketaki
    Kullberg-Lindh, Carola
    Borg, Helena
    Ejnell, Hasse
    Sumitran-Holgersson, Suchitra
    LANCET, 2012, 380 (9838): : 230 - 237
  • [25] The Use of Autologous Tissue for Chest Feminization in Gender-Affirming Surgery
    Morrison, Shane D.
    Massie, Jonathan P.
    Kneib, Cameron J.
    Massenburg, Benjamin B.
    Impastato, Katherine
    Said, Hakim K.
    Cederna, Paul S.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 145 (01) : 228E - 229E
  • [26] Functional Neuroimaging During Asleep DBS Surgery: A Proof of Concept Study
    Sammartino, Francesco
    Taylor, Paul
    Chen, Gang
    Reynolds, Richard C.
    Glen, Daniel
    Krishna, Vibhor
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [27] Combined Laparoscopic Bariatric Surgery and Thyroidectomy: A Proof-of-Concept Study
    Guan, Bingsheng
    Chen, Yanya
    Wu, Zhenpeng
    Chong, Tsz Hong
    Ming, Wai-kit
    Wang, Cunchuan
    Huang, Shifang
    Lee, Wei-Jei
    Yang, Jingge
    BARIATRIC SURGICAL PRACTICE AND PATIENT CARE, 2023, 18 (03) : 181 - 188
  • [28] Using Quicktome for Intracerebral Surgery: Early Retrospective Study and Proof of Concept
    Yeung, Jacky T.
    Taylor, Hugh M.
    Nicholas, Peter J.
    Young, Isabella M.
    Jiang, Ivy
    Doyen, Stephane
    Sughrue, Michael E.
    Teo, Charles
    WORLD NEUROSURGERY, 2021, 154 : E734 - E742
  • [29] Medically Reproducing Bariatric Surgery (MRB): A Proof-of-Concept Study
    Dar, Moahad
    Smythe, Kevin F.
    Leggett-Frazier, Nancy K.
    Yancy, William S., Jr.
    DIABETES, 2019, 68
  • [30] Systematic use of intraureteral indocyanine green: a game changer in endometriosis surgery. A proof-of-concept study
    Centini, Gabriele
    Colombi, Irene
    Cannoni, Alberto
    Habib, Nassir
    Giorgi, Matteo
    Ginetti, Alessandro
    Lazzeri, Lucia
    Fedele, Francesco
    Zupi, Errico
    Martire, Francesco Giuseppe
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2024, 33 (05) : 287 - 294