Pre-use intraoperative testing of autologous tissue for valvular surgery: A proof of concept study

被引:0
|
作者
Hanlon, JG
Suggit, RW
Love, JW
机构
[1] CardioMend LLC, Santa Barbara, CA USA
[2] McLean Engn, Vancouver, BC, Canada
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 06期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Autologous tissue is being used more commonly for valvular repair and reconstruction, but methods for testing the mechanical properties of the tissue intraoperatively have not been available. Before committing to its use, the surgeon should know its thickness, strength, and if it is isotropic or anisotropic. We have developed an intraoperative tissue tester (ITT), based on optical and mechanical methods that allows a surgeon to assess these parameters rapidly. Methods: Tissue thickness was measured with a micrometer. Specimens of tissue were incrementally pressurized to 200 mmHg, resulting in a dome-shaped distortion. The dome is a section of a spheroid whose dimensions are determined by the diameter of the circle and the height of the dome. The LaPlace equation for a sphere was used to calculate tissue stress. Moire fringe patterns are visualized as concentric circles or ellipses produced by directing a beam of collimated light at 45 degrees through a grid with Ronchi rulings onto the surface of the dome. Circles indicate isotropy and ellipses indicate anisotropy. Uniaxial testing was performed on strips of tissue taken from orthogonal and intermediate axes to validate Moire fringe pattern analysis. Specimens of human pericardium (n = 8), lightly tanned by a 10-min immersion in buffered 0.625% glutaraldehyde, were examined. Results: Mean thickness of eight specimens was 0.61 mm (range: 0.41-0.99 mm). During inflation, the lightly tanned human pericardium showed non-linear deformation characteristic of pericardium. Mean peak stress for the dome was 136 kPa. There was good correlation between dome height in the inflation tester and the uniaxial Young's modulus. Moire fringe pattern analysis showed minimal anisotropy to 200 mmHg pressure, confirmed by uniaxial testing. Conclusions: The basic mechanical properties of autologous tissue to be used for valvular repair or reconstruction should be determined to avoid use of tissue that is outside an expected range of values for strength, anisotropy/isotropy and thickness. A self-contained ITT, based on optical and mechanical principles, has been developed to measure those parameters.
引用
收藏
页码:614 / 623
页数:10
相关论文
共 50 条
  • [1] Pre-use intraoperative testing of autologous tissue for valvular surgery: A proof of concept study - Discussion
    Kunzleman, K
    Love, J
    Deac, R
    Vesely, I
    Barratt-Boyes, B
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (06): : 623 - 624
  • [2] Pre-use Filter-Integrity Testing: To Test or not to Test?
    Martin, Jerold
    BIOPHARM INTERNATIONAL, 2012, 25 (08) : 16 - +
  • [3] Proof of concept testing of a vascular closure device for use in fetal surgery
    Forde, Braxton
    Martin, Samuel
    Oria, Marc
    Kapke, Jordan
    Krispin, Eyal
    Peiro, Jose L.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2025, 38 (01):
  • [4] Proof-of-concept testing of vascular closure devices for use in fetal surgery
    Forde, Braxton
    Martin, Samuel
    Oria, Marc
    Kapke, Jordan
    Peiro, Jose L.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2024, 230 (01) : S527 - S527
  • [5] Use of intraoperative CT to predict the accuracy of microelectrode recording during deep brain stimulation surgery. A proof of concept study
    Kochanski, Ryan B.
    Kerolus, Mena G.
    Pal, Gian
    Merman, Leo Verhagen
    Sani, Sepehr
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2016, 150 : 164 - 168
  • [6] Orthogonal pre-use and post-use efficiency testing for single-use anion exchange chromatography
    Hester, Jonathan F.
    Lu, Xinran
    Calhoun, Jacob D.
    Hochstein, Rebecca A.
    Olson, Eric J.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1654
  • [7] Use of tissue Doppler imaging to diagnose fetal inflammation: a proof of concept study
    Stock, S. J.
    Patey, O.
    White, S.
    Thilaganathan, B.
    Newnham, J.
    Kemp, M.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2015, 122 : 4 - 4
  • [8] AUTOLOGOUS TISSUE ENGINEERED GRAFT FOR PHALANX CONSTRUCTION IN CHILDREN WITH SYMBRACHYDACTYLY, A PROOF OF CONCEPT
    Schaller, R.
    Chaaban, M.
    Zhang, G.
    Schafer, D.
    Kaempfen, A.
    Martin, I.
    Scherberich, A.
    Moya, A.
    CYTOTHERAPY, 2023, 25 (06) : S143 - S143
  • [9] Practical issues and process solutions to post SIP and pre-use integrity testing of sterilizing grade filters
    Rachon, Alain
    37th R3-Nordic Contamination Control Symposium, 2006, 240 : 93 - 95
  • [10] In Vivo Application of Tissue-Engineered Veins Using Autologous Peripheral Whole Blood: A Proof of Concept Study
    Olausson, Michael
    Kuna, Vijay Kumar
    Travnikova, Galyna
    Backdahl, Henrik
    Patil, Pradeep B.
    Saalman, Robert
    Borg, Helena
    Jeppsson, Anders
    Sumitran-Holgersson, Suchitra
    EBIOMEDICINE, 2014, 1 (01): : 72 - 79