Day and Night Home Closed-Loop Insulin Delivery in Adults With Type 1 Diabetes: Three-Center Randomized Crossover Study

被引:91
|
作者
Leelarathna, Lalantha [1 ,2 ]
Dellweg, Sibylle [3 ]
Mader, Julia K. [4 ]
Allen, Janet M. [1 ]
Benesch, Carsten [3 ]
Doll, Werner [4 ]
Ellmerer, Martin [4 ]
Hartnell, Sara [2 ]
Heinemann, Lutz [3 ]
Kojzar, Harald [4 ]
Michalewski, Lucy [3 ]
Nodale, Marianna [1 ]
Thabit, Hood [1 ,2 ]
Wilinska, Malgorzata E. [1 ]
Pieber, Thomas R. [4 ]
Arnolds, Sabine [3 ]
Evans, Mark L. [1 ,2 ]
Hovorka, Roman [1 ]
机构
[1] Univ Cambridge, Wellcome Trust Med Res Clin Inst Metab Sci, Cambridge, England
[2] Cambridge Univ Hosp Natl Hlth Serv Fdn Trust, Addenbrookes Hosp, Dept Diabet & Endocrinol, Cambridge, England
[3] Profil Inst Stoffwechselforsch GmbH, Neuss, Germany
[4] Med Univ Graz, Dept Internal Med, Div Endocrinol & Metab, Graz, Austria
关键词
ARTIFICIAL PANCREAS; GLYCEMIC CONTROL; GLUCOSE CONTROL; SEVERE HYPOGLYCEMIA; CONTROLLED-TRIAL; SYSTEM; FEASIBILITY; INFUSION; GLUCAGON; THERAPY;
D O I
10.2337/dc13-2911
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE To evaluate the feasibility of day and night closed-loop insulin delivery in adults with type 1 diabetes under free-living conditions. RESEARCH DESIGN AND METHODS Seventeen adults with type 1 diabetes on insulin pump therapy (means +/- SD age 34 +/- 9 years, HbA(1c) 7.6 +/- 0.8%, and duration of diabetes 19 +/- 9 years) participated in an open-label multinational three-center crossover study. In a random order, participants underwent two 8-day periods (first day at the clinical research facility followed by 7 days at home) of sensor-augmented insulin pump therapy (SAP) or automated closed-loop insulin delivery. The primary end point was the time when sensor glucose was in target range between 3.9 and 10.0 mmol/L during the 7-day home phase. RESULTS During the home phase, the percentage of time when glucose was in target range was significantly higher during closed-loop compared with SAP (median 75% [interquartile range 61-79] vs. 62% [53-70], P = 0.005). Mean glucose (8.1 vs. 8.8 mmol/L, P = 0.027) and time spent above target (P = 0.013) were lower during closed loop, while time spent below target was comparable (P = 0.339). Increased time in target was observed during both daytime (P = 0.017) and nighttime (P = 0.013). CONCLUSIONS Compared with SAP, 1 week of closed-loop insulin delivery at home reduces mean glucose and increases time in target without increasing the risk of hypoglycemia in adults with relatively well-controlled type 1 diabetes.
引用
收藏
页码:1931 / 1937
页数:7
相关论文
共 50 条
  • [41] Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes
    Dadlani, Vikash
    Pinsker, Jordan E.
    Dassau, Eyal
    Kudva, Yogish C.
    CURRENT DIABETES REPORTS, 2018, 18 (10)
  • [42] Psychological outcomes of evening and night closed-loop insulin delivery under free living conditions in people with Type 1 diabetes: a 2-month randomized crossover trial
    Kropff, J.
    DeJong, J.
    del Favero, S.
    Place, J.
    Messori, M.
    Coestier, B.
    Farret, A.
    Boscari, F.
    Galasso, S.
    Avogaro, A.
    Bruttomesso, D.
    Cobelli, C.
    Renard, E.
    Magni, L.
    DeVries, J. H.
    DIABETIC MEDICINE, 2017, 34 (02) : 262 - 271
  • [43] Day and Night Closed-Loop Control in Adults With Type 1 Diabetes A comparison of two closed-loop algorithms driving continuous subcutaneous insulin infusion versus patient self-management
    Luijf, Yoeri M.
    DeVries, J. Hans
    Zwinderman, Koos
    Leelarathna, Lalantha
    Nodale, Marianna
    Caldwell, Karen
    Kumareswaran, Kavita
    Elleri, Daniela
    Allen, Janet M.
    Wilinska, Malgorzata E.
    Evans, Mark L.
    Hovorka, Roman
    Doll, Werner
    Ellmerer, Martin
    Mader, Julia K.
    Renard, Eric
    Place, Jerome
    Farret, Anne
    Cobelli, Claudio
    Del Favero, Simone
    Dalla Man, Chiara
    Avogaro, Angelo
    Bruttomesso, Daniela
    Filippi, Alessio
    Scotton, Rachele
    Magni, Lalo
    Lanzola, Giordano
    Di Palma, Federico
    Soru, Paola
    Toffanin, Chiara
    De Nicolao, Giuseppe
    Arnolds, Sabine
    Benesch, Carsten
    Heinemann, Lutz
    DIABETES CARE, 2013, 36 (12) : 3882 - 3887
  • [44] Variability of Insulin Requirements in Adults with Type 2 Diabetes During Fully Closed-Loop Insulin Delivery
    Lakshman, Rama
    Daly, Aideen B.
    Nwokolo, Munachiso
    Hartnell, Sara
    Wilinska, Malgorzata E.
    Cezar, Alina
    Evans, Mark L.
    Hovorka, Roman
    Boughton, Charlotte K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 (06) : 442 - 444
  • [45] Empagliflozin add-on therapy to closed-loop insulin delivery in type 1 diabetes: a 2 x 2 factorial randomized crossover trial
    Haidar, Ahmad
    Lovblom, Leif Erik
    Cardinez, Nancy
    Gouchie-Provencher, Nikita
    Orszag, Andrej
    Tsoukas, Michael A.
    Falappa, C. Marcelo
    Jafar, Adnan
    Ghanbari, Milad
    Eldelekli, Devrim
    Rutkowski, Joanna
    Yale, Jean-Francois
    Perkins, Bruce A.
    NATURE MEDICINE, 2022, 28 (06) : 1269 - +
  • [46] Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial
    Hovorka, Roman
    Allen, Janet M.
    Elleri, Daniela
    Chassin, Ludovic J.
    Harris, Julie
    Xing, Dongyuan
    Kollman, Craig
    Hovorka, Tomas
    Larsen, Anne Mette F.
    Nodale, Marianna
    De Palma, Alessandro
    Wilinska, Malgorzata E.
    Acerini, Carlo L.
    Dunger, David B.
    LANCET, 2010, 375 (9716): : 743 - 751
  • [47] DAY AND NIGHT CLOSED-LOOP CONTROL WITH THE DIAS SYSTEM IN PATIENTS WITH TYPE 1 DIABETES AT CAMP
    Ly, T.
    Chernavvsky, D.
    DeSalvo, D.
    Shanmugham, S.
    Breton, M.
    Buckingham, B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A98 - A98
  • [48] Closed-loop insulin delivery in pregnant women with type 1 diabetes (CRISTAL): a multicentre randomized controlled trial - study protocol
    Beunen, Kaat
    Van Wilder, Nancy
    Ballaux, Dominique
    Vanhaverbeke, Gerd
    Taes, Youri
    Aers, Xavier-Philippe
    Nobels, Frank
    Marlier, Joke
    Lee, Dahae
    Cuypers, Joke
    Preumont, Vanessa
    Siegelaar, Sarah E.
    Painter, Rebecca C.
    Laenen, Annouschka
    Gillard, Pieter
    Mathieu, Chantal
    Benhalima, Katrien
    BMC PREGNANCY AND CHILDBIRTH, 2023, 23 (01)
  • [49] Closed-loop insulin delivery in pregnant women with type 1 diabetes (CRISTAL): a multicentre randomized controlled trial – study protocol
    Kaat Beunen
    Nancy Van Wilder
    Dominique Ballaux
    Gerd Vanhaverbeke
    Youri Taes
    Xavier-Philippe Aers
    Frank Nobels
    Joke Marlier
    Dahae Lee
    Joke Cuypers
    Vanessa Preumont
    Sarah E. Siegelaar
    Rebecca C. Painter
    Annouschka Laenen
    Pieter Gillard
    Chantal Mathieu
    Katrien Benhalima
    BMC Pregnancy and Childbirth, 23
  • [50] Safety of a Hybrid Closed-Loop Insulin Delivery System in Patients With Type 1 Diabetes
    Bergenstal, Richard M.
    Garg, Satish
    Weinzimer, Stuart A.
    Buckingham, Bruce A.
    Bode, Bruce W.
    Tamborlane, William V.
    Kaufman, Francine R.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2016, 316 (13): : 1407 - 1408