A generalized Wolter Type I design for wide-field X-ray imaging applications

被引:0
|
作者
Harvey, JE [1 ]
Thompson, PL [1 ]
机构
[1] Univ Cent Florida, Ctr Res & Educ Opt & Lasers, Orlando, FL 32826 USA
关键词
grazing incidence X-ray telescopes; generalized Wolter Type I telescope design;
D O I
10.1117/12.368229
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Surface scatter effects are a dominant image degradation mechanism for very short X-ray wavelengths, even for state-of-the-art optical surfaces. And the severe off-axis aberrations of the classical Welter Type 1 grazing incidence X-ray telescope consisting of a confocal paraboloid and hyperboloid severely limit the useful angular field that can be imaged onto a flat detector. A new family of alternative designs based on two hyperboloids has been developed that improves the wide-field imaging performance by aberration balancing and a complete optical systems engineering analysis. A particular member of this family, designated as H-T#17, has been selected for use in the Solar X-ray Imager (SXI) instrument to be integrated into the NOAA GOES satellite. The development of the SXI optical prescription lid its defining parameters are first presented, then detailed image quality predictions, as degraded by diffraction effects, geometrical aberrations, surface scatter effects, and all other residual errors in the mirror manufacturers error budget tree are presented. This new optimized design yields an 80% increase in the number of spatial resolution elements over the full solar disc when compared to the classical Welter Type I design that was the SXI baseline design.
引用
收藏
页码:371 / 381
页数:11
相关论文
共 50 条
  • [11] Novel X-ray telescopes for wide-field X-ray monitoring
    Hudec, R
    Inneman, A
    Pina, L
    Svéda, L
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-COLLOQUIA ON PHYSICS, 2005, 28 (4-5): : 743 - 746
  • [12] WIDE-FIELD X-RAY TUBE COMPARISONS
    BERNSTEIN, H
    BERGERON, RT
    RADIOLOGY, 1976, 119 (03) : 697 - 703
  • [13] Grazing-incidence hyperboloid-hyperboloid designs for wide-field x-ray imaging applications
    Harvey, JE
    Krywonos, A
    Thompson, PL
    Saha, TT
    APPLIED OPTICS, 2001, 40 (01) : 136 - 144
  • [14] Hyperboloid-hyperboloid grazing incidence x-ray telescope designs for wide-field imaging applications
    Harvey, JE
    Thompson, PL
    Krywonos, A
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 328 - 341
  • [15] Simulation method of Wolter type I grazing incidence telescope imaging of an X-ray region
    Liu, Peng
    Chen, Bo
    Zhang, Ya-Chao
    He, Ling-Ping
    Wang, Xiao-Dong
    RESEARCH IN ASTRONOMY AND ASTROPHYSICS, 2019, 19 (12)
  • [16] Development of an imaging performance criterion for wide-field grazing incidence X-ray telescopes
    Thompson, PL
    Harvey, JE
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS II, 1999, 3766 : 162 - 172
  • [17] X-ray surveys and wide-field optical/near-infrared imaging with JDEM
    Brandt, WN
    NEW ASTRONOMY REVIEWS, 2005, 49 (7-9) : 430 - 435
  • [18] Optimization of a Wolter type I mirror for a soft X-ray microscope
    Chon, KS
    Namba, Y
    Yoon, KH
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2006, 30 (02): : 223 - 230
  • [19] IMAGING PROPERTIES OF WOLTER-1 TYPE X-RAY TELESCOPES
    WERNER, W
    APPLIED OPTICS, 1977, 16 (03): : 764 - 773
  • [20] Design of the Permanent Magnet Diverter for Deflecting Electrons on Wide-Field X-Ray Telescope
    Wang, Lei
    Qin, Lang
    Cheng, Junsheng
    Zhang, Zili
    Wang, Yaohui
    Liu, Jianhua
    Hu, Xinning
    Wang, Qiuliang
    Zhang, Chen
    Zhao, Donghua
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (04)