New limited sampling strategy for determining 5-fluorouracil area under the concentration-time curve after rapid intravenous bolus

被引:14
|
作者
Gusella, M
Ferrazzi, E
Ferrari, M
Padrini, R
机构
[1] Univ Padua, Dept Pharmacol & Anesthesiol, I-35131 Padua, Italy
[2] Univ Padua, Dept Clin & Expt Med, I-35131 Padua, Italy
[3] Rovigo Hosp, Div Oncol, Rovigo, Italy
关键词
5-fluorouracil; limited sampling method; area under the curve; pharmacokinetics;
D O I
10.1097/00007691-200206000-00016
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
All limited sampling models so far proposed to determine the area under the concentration-time curve (AUC) of anticancer drugs can be applied only to the dosing/sampling schedule used to obtain the model. The authors have developed a new method to predict the AUC of 5-fluorouracil (5-FU) after rapid intravenous bolus administration of various doses, using as few as two plasma drug concentrations. The 5-FU AUC (AUC(true)) was First determined in 20 patients receiving adjuvant therapy for colorectal cancer, based on nine plasma drug concentrations obtained at 0, 2.5, 5, 10, 15, 20, 30, 45, and 60 minutes after drug administration. Ten patients received 375 mg/m(2) 5F-U + 100 mg/m(2) leucovorin and 10 received 425 mg/m(2) 5-FU + 20 mg/m(2) leucovorin. The kinetics of 5-FU was described by either a one- or two-compartment linear model, as needed. The AUC was then recalculated (AUC(approx)) using a reduced number of plasma concentrations and a simple one-compartment model. The time combinations tested Were 2.5, 5, 10, and 20; 2.5, 10, and 20; 5, 10, and 20; 5 and 20; and 2,5 and 20 minutes. The accuracy and precision of the method in predicting the AUC(true) were measured by calculating the mean prediction error (MPE%) and the mean absolute error (MAE%) of the AUC(approx). MPE% ranged between -0.8% and -8.3% and MAE% between 6.1% and 9.5%, depending on the time combination used. In general, all limited sampling models tested tended to underestimate the AUC(true) slightly, particularly when 5-FU kinetics followed a two-compartment model, but bias was still within acceptable limits. The best results were obtained with plasma concentrations measured at 2.5 and 20 minutes after drug bolus (MPE%, -0.8%; MAE%, 6.1%). Although 5-FU kinetics was dose-dependent, MPE% and MAE% were not significantly different between the two groups. These data show that 5-FU AUC can be reliably predicted by using just two plasma concentrations and a one-compartment model, even when different doses are used and plasma concentration decay is biexponential.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [41] Estimation of the area under the concentration-time curve of racemic lansoprazole by using limited plasma concentration of lansoprazole enantiomers
    Niioka, Takenori
    Miura, Masatomo
    Uno, Tsukasa
    Yasui-Furukori, Norio
    Hayakari, Makoto
    Tateishi, Tomonori
    Suzuki, Toshio
    [J]. EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 2008, 64 (05) : 503 - 509
  • [42] A Limited Sampling Strategy to Estimate the Area Under the Concentration-Time Curve of Tacrolimus Modified-release Once-daily Preparation in Renal Transplant Recipients
    Niioka, Takenori
    Miura, Masatomo
    Kagaya, Hideaki
    Saito, Mitsuru
    Numakura, Kazuyuki
    Habuchi, Tomonori
    Satoh, Shigeru
    [J]. THERAPEUTIC DRUG MONITORING, 2013, 35 (02) : 228 - 232
  • [43] Estimation of the area under the concentration-time curve of racemic lansoprazole by using limited plasma concentration of lansoprazole enantiomers
    Takenori Niioka
    Masatomo Miura
    Tsukasa Uno
    Norio Yasui-Furukori
    Makoto Hayakari
    Tomonori Tateishi
    Toshio Suzuki
    [J]. European Journal of Clinical Pharmacology, 2008, 64 : 503 - 509
  • [44] Evaluation of Intravenous Midazolam Limited Sampling Strategies for Prediction of Area Under the Concentration-Time Curve During Baseline Cytochrome P450 3A Conditions
    Hoffman, Justin T.
    Nguyen, Anh N.
    Jang, In-Jin
    Kharasch, Evan
    Ma, Joseph D.
    [J]. JOURNAL OF CLINICAL PHARMACOLOGY, 2011, 51 (09): : 1334 - 1335
  • [45] Development and Validation of Limited Sampling Strategies for Estimation of Cyclosporine Area Under the Concentration-Time Curve in Hematopoietic Stem Cell Transplant Patients
    Hadjibabaie, Molouk
    Vazirian, Iman
    Iravani, Masoud
    Moosavi, Seyed Asadollah
    Alimoghaddam, Kamran
    Ghavamzadeh, Ardeshir
    Rezaee, Saeed
    [J]. THERAPEUTIC DRUG MONITORING, 2011, 33 (06) : 673 - 680
  • [46] Pharmacokinetics of bolus 5-fluorouracil: Relationship between dose, plasma concentrations,, area-under-the-curve and toxicity
    Codacci-Pisanelli, G
    Pinedo, HM
    Lankelma, J
    Van Groeningen, CJ
    Van Kuilenburg, ABP
    Van Gennip, AH
    Peters, GJ
    [J]. JOURNAL OF CHEMOTHERAPY, 2005, 17 (03) : 315 - 320
  • [47] Two-point blood sampling is sufficient and necessary to estimate the area under the concentration-time curve for intravenous busulfan in infants and young children
    Utano, Tomoyuki
    Kato, Motohiro
    Sakamoto, Kenichi
    Osumi, Tomoo
    Matsumoto, Kana
    Tomizawa, Daisuke
    Matsumoto, Kimikazu
    Yamatani, Akimasa
    [J]. PEDIATRIC BLOOD & CANCER, 2021, 68 (08)
  • [48] A Systematic Review of Multiple Linear Regression-Based Limited Sampling Strategies for Mycophenolic Acid Area Under the Concentration-Time Curve Estimation
    Sobiak, Joanna
    Resztak, Matylda
    [J]. EUROPEAN JOURNAL OF DRUG METABOLISM AND PHARMACOKINETICS, 2021, 46 (06) : 721 - 742
  • [49] Limited sampling strategy for the estimation of mycophenolic acid area under the plasma concentration-time curve in adult patients undergoing liver transplant (vol 29, pg 207, 2007)
    Zicheng, Y.
    Weixia, Z.
    Hao, C.
    Hongzhuan, C.
    [J]. CLINICAL PHARMACOKINETICS, 2008, 47 (03) : 216 - 216
  • [50] Sampling strategy to calculate the cyclosporin-A area under the time-concentration curve
    David-Neto, E
    Araujo, LMP
    Brito, ZML
    Alves, CF
    Lemos, FC
    Yagyu, EM
    Nahas, WC
    Ianhez, LE
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2002, 2 (06) : 546 - 550