High signal-to-noise ratio HgI2 X-ray detector assisted with ultraviolet radiation

被引:7
|
作者
Lee, Dongwook [1 ,2 ]
Lee, Kangho [1 ,3 ]
Seo, Jiwon [2 ]
机构
[1] Samsung Adv Inst Technol, 130 Samsung Ro, Suwon 443803, Gyeonggi Do, South Korea
[2] Yonsei Univ, Dept Phys, Coll Sci & Technol, 1 Yonseidae Gil, Wonju 26493, Gangwon Do, South Korea
[3] Korea Inst Machinery & Mat, Daegu Res Ctr Med Devices & Green Energy, 1031 R&D Ctr, Daegu, South Korea
关键词
HgI2; X-ray detector; Photoconductor; FLAT-PANEL; A-SE; PHOTOCONDUCTORS; SENSITIVITY; PERFORMANCE;
D O I
10.1016/j.nima.2019.162364
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A direct-conversion active matrix flat panel X-ray imaging detector was fabricated with an HgI2 photoconductor. The HgI2 photoconductive layer was coated on an amorphous Si thin film transistor panel with a particle-in-binder process. The micro-morphological properties of the HgI2 photoconductive layer were characterized by micro-computed tomography, X-ray diffraction, and scanning electron microscopy. The volume density of HgI2 in the layer was 40.9%. The effect of the bias voltage on the sensitivity of the HgI2 photoconductor was investigated with different photon irradiations such as ultraviolet and visible light as one of reset processes. The sensitivity of the HgI2 photoconductor was increased with the help of ultraviolet radiation before X-ray radiation, which released trapped carriers inside the photoconductor and increased the sensitivity of the HgI2 photoconductor. Moreover, ultraviolet irradiation with a DC bias stabilized the sensitivity variation. An X-ray imaging detector in conjunction with anHgI(2) photoconductor shows a very high signal-to-noise ratio.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] The hard X-ray response of a large area HgI2 detector
    Owens, A
    Andersson, H
    Bavdaz, M
    van den Berg, L
    Peacock, A
    Puig, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 90 - 95
  • [2] Ultraviolet thermoelectric single photon detector with high signal-to-noise ratio
    Kuzanyan, Astghik A.
    Nikoghosyan, Vahan R.
    Kuzanyan, Armen S.
    [J]. OPTICAL ENGINEERING, 2024, 63 (01)
  • [3] The hard X-ray response of HgI2
    Owens, A
    Bavdaz, M
    Brammertz, G
    Krumrey, M
    Martin, D
    Peacock, A
    Tröger, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3): : 535 - 547
  • [4] Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector
    Kitagawa, H
    Farman, AG
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) : 21 - 24
  • [5] Computations of the Signal-to-Noise Ratio for Medical X-Ray Imagers
    Lo, Yu-Chen
    Huang, Kuan-Chieh
    Yang, Kei-Hsiung
    [J]. CHINESE JOURNAL OF PHYSICS, 2014, 52 (04) : 1277 - 1287
  • [6] Spatial resolution and signal-to-noise ratio in X-ray imaging
    Gureyev, T. E.
    Paganin, D. M.
    Kozlov, A.
    Quiney, H. M.
    [J]. QUANTITATIVE PHASE IMAGING V, 2019, 10887
  • [7] High resolution x-ray image sensors based on HgI2
    Street, RA
    Mulato, M
    Ready, SE
    Lau, R
    Ho, J
    VanSchuylenbergh, K
    Schieber, M
    Hermon, H
    Zuck, A
    Vilensky, A
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 189 - 196
  • [8] SIGNAL-TO-NOISE RATIO AT THE OUTPUT OF A FLAW DETECTOR WITH A MOSAIC SEMICONDUCTOR HARD X-RAY DETECTOR AND DIGITAL SIGNAL PROCESSING.
    Gerasenov, N.Yu.
    Rubinovich, I.M.
    [J]. The Soviet journal of nondestructive testing, 1983, 19 (01): : 58 - 64
  • [9] EVAPORATIVE DEGRADATION OF HGI2 X-RAY DETECTORS
    SCOTT, RS
    FREDERICKS, GE
    [J]. APPLIED PHYSICS LETTERS, 1975, 27 (02) : 99 - 100
  • [10] NEW DEVELOPMENT OF HGI2 X-RAY AND SOFT GAMMA-RAY DETECTOR FOR SYNCHROTRON RADIATION RESEARCH AND DOSIMETRY APPLICATIONS
    GERVINO, G
    MONTICONE, E
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1992, 32 (1-3) : 455 - 463