Effect of beam energy and filtration on the signal-to-noise ratio of the Dexis intraoral X-ray detector

被引:10
|
作者
Kitagawa, H [1 ]
Farman, AG [1 ]
机构
[1] Univ Louisville, Hlth Sci Ctr, Sch Dent, Div Radiol & Imaging Sci, Louisville, KY 40292 USA
关键词
charge-coupled device; digital imaging; filtration; radiography; dental; X-ray beam energy;
D O I
10.1259/dmfr/26493631
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the signal-to-noise ratio (SNR) of the Dexis charge-coupled device (CCD) intraoral X-ray detector, with special reference to the influence of beam energy and filtration. Material and methods: Digital radiographic images were made of a Dine-step dental aluminium step wedge using a Dexis intraoral detector. The X-ray generator was a GE 1000 operating at 10 mA with 2.7 mm aluminium filtration. The peak tube voltage settings applied were 50 kVp, 60 kVp, 70 kVp, 80 kVp and 90 kVp. Various exposure times were used at each beam energy and the exposures (in muC kg(-1)) were determined in each case using a 3 cl beryllium-windowed ionization chamber. SNR was defined using the surrogate measure of mean pixel value (surrogate for signal) divided by the standard deviation of the pixel value (surrogate for noise). SNRs were measured at separate regions of interest (ROIs) at the centre and at both sides of the detector for each aluminium step as well as without the step. Results: For beam energies of 50 kVp and 60 kVp, the estimated SNR improved both with increased exposure and with increased filtration (thickness of the aluminium step), and image saturation did not occur within the exposure time range permitted by the Dexis software. At 70 kVp and above, the SNR was optimized in the middle of the exposure range: 4 muC kg(-1) with 290:1 at the ninth step (13.5 mm Al) for 70 kVp; 3.5 muC kg(-1) with 240:1 at the ninth step (13.5 mm Al) for 80 kVp; 3.5 muC kg(-1) with 160:1 at the ninth step (13.5 mm Al) for 90 kVp. Saturation did occur at these beam energies within the exposure time range permitted by the Dexis software. Conclusion: For the Dexis intraoral radiographic imaging system, estimated SNR improved both with higher filtration and with lower kVp. The Dexis detector was capable of generating acceptable images of the step wedge at a wide range of kVp settings.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [1] Effects of beam energy and filtration on the signal-to-noise ratio achieved with the Dexis intra-oral charge-coupled device x-ray system
    Kitagawa, H
    Farman, AG
    Kelly, MS
    Kuroyanagi, K
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 376 - 376
  • [2] Computations of the Signal-to-Noise Ratio for Medical X-Ray Imagers
    Lo, Yu-Chen
    Huang, Kuan-Chieh
    Yang, Kei-Hsiung
    CHINESE JOURNAL OF PHYSICS, 2014, 52 (04) : 1277 - 1287
  • [3] Spatial resolution and signal-to-noise ratio in X-ray imaging
    Gureyev, T. E.
    Paganin, D. M.
    Kozlov, A.
    Quiney, H. M.
    QUANTITATIVE PHASE IMAGING V, 2019, 10887
  • [4] SIGNAL-TO-NOISE RATIO AT THE OUTPUT OF A FLAW DETECTOR WITH A MOSAIC SEMICONDUCTOR HARD X-RAY DETECTOR AND DIGITAL SIGNAL PROCESSING.
    Gerasenov, N.Yu.
    Rubinovich, I.M.
    The Soviet journal of nondestructive testing, 1983, 19 (01): : 58 - 64
  • [5] High signal-to-noise ratio HgI2 X-ray detector assisted with ultraviolet radiation
    Lee, Dongwook
    Lee, Kangho
    Seo, Jiwon
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 941
  • [6] Optimized Detector Angle for Improving signal-to-noise ratio of Pinhole X-ray Fluorescence Computed Tomography
    Guo, Jing
    Feng, Peng
    Deng, Luzhen
    Luo, Yan
    He, Peng
    ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [7] Optimizing the signal-to-noise ratio for X-ray photon correlation spectroscopy
    Falus, P
    Lurio, LB
    Mochrie, SGJ
    JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 : 253 - 259
  • [8] Technical evaluation of the Dexis, intraoral dental x-ray sensor
    Vandre, RH
    Pajak, JC
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 963 - 968
  • [9] Effect of exposure and scattering on signal-to-noise ratio for improved defect sensitivity in X-ray radiography
    Saravanan, T.
    Arunmuthu, K.
    Philip, John
    Rao, B. Puma Chandra
    Jayakumar, T.
    INSIGHT, 2013, 55 (10) : 548 - 552
  • [10] Signal-to-noise ratio optimization in X-ray fluorescence spectrometry for chromium contamination analysis
    An, Siwen
    Reza, Salim
    Norlin, Borje
    Frojdh, Christer
    Thungstrom, Goran
    TALANTA, 2021, 230