We calibrated several industrial-grade platinum-resistance-thermometers (IPRT) using the ITS-90 fixed points in the range from the triple point of mercury to the freezing point of zinc. Calibration parameters were calculated for the ITS-90 deviation-function (DeltaW(90)) and for the Callendar-Van Dusen (CVD) model. Some of the IPRTs used in this exercise fulfil the ITS-90 acceptation criteria either W(Hg) or W(Ga), while others clearly do not fulfil them. However, all these instruments follow closely the ITS-90 interpolation model. National Laboratories of some developing countries as well as most of secondary and industry laboratories around the world use IPRTs as reference standards. The calibrations of these thermometers by fixed points and by using the ITS-90 model reduces the instrumental uncertainty from about 50 mK (typical of the CVD model) to 7-10 mK thus, this procedure may improve the measurement capabilities of those laboratories.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 50 条
  • [21] Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
    A. G. Ivanova
    S. F. Gerasimov
    A. I. Pokhodun
    V. М. Fuksov
    [J]. Measurement Techniques, 2021, 64 : 573 - 579
  • [22] Matrix Presentation of Uncertainties Propagation in the Realization of ITS-90 Temperature Scale using Standard Platinum Resistance Thermometers
    Palencar, Rudolf
    Duris, Stanislav
    Palencar, Jakub
    Halaj, Martin
    Soos, Lubomir
    [J]. MEASUREMENT SCIENCE REVIEW, 2020, 20 (02) : 73 - 79
  • [23] Radiation thermometry for the determination of high temperature fixed points of the ITS-90
    Fischer, J
    [J]. METROLOGY - AT THE THRESHOLD OF THE CENTURY ARE WE READY?, 1999, : 627 - 635
  • [24] Determination of the uncertainties for ITS-90 realization by SPRTs between fixed points
    Meyer, C. W.
    Ripple, D. C.
    [J]. METROLOGIA, 2006, 43 (05) : 327 - 340
  • [25] Comparing fixed points of the ITS-90 as realized in Canada, Argentina and Brazil
    Ancsin, J
    Tischler, M
    Petkovic, SG
    Santiago, JFN
    [J]. METROLOGIA, 2001, 38 (06) : 555 - 566
  • [26] Modelling the calibration of the industrial platinum-resistance thermometers according to GUM
    Inseok Yang
    Kee Sool Gam
    Wukchul Joung
    Yong-Gyoo Kim
    [J]. Accreditation and Quality Assurance, 2013, 18 : 359 - 362
  • [27] Modelling the calibration of the industrial platinum-resistance thermometers according to GUM
    Yang, Inseok
    Gam, Kee Sool
    Joung, Wukchul
    Kim, Yong-Gyoo
    [J]. ACCREDITATION AND QUALITY ASSURANCE, 2013, 18 (04) : 359 - 362
  • [28] A criterion for uniformity of a temperature field in realization of the ITS-90 fixed points
    Ilin, AU
    [J]. TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 297 - 301
  • [29] Calibration of Platinum Resistance Thermometers.
    Castellanos Julian, Fernandez
    [J]. Revista del Instituto Mexicano del Petroleo, 1981, 13 (04): : 56 - 62
  • [30] REFLECTIONS ON CALIBRATION OF PLATINUM RESISTANCE THERMOMETERS
    ATHERTON, A
    [J]. TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 1994, 16 (03) : 118 - 127