Elimination of chemical products in the pre-treatment section of Las Palmas III reverse osmosis desalination plant to control fouling

被引:4
|
作者
Munoz Elguera, A. [1 ]
Perez Baez, S. O. [1 ]
机构
[1] Univ Las Palmas Gran Canaria, Dept Proc Engn, Campus Tafira Baja, Las Palmas Gran Canaria 35017, Spain
关键词
Scaling; Fouling; Biofouling; Reverse osmosis; Pre-treatment;
D O I
10.1016/j.desal.2018.02.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The paper analyses the extrapolation of the results obtained in a pilot plant to a full-scale seawater desalination plant. A technological system was implemented in the pre-treatment line of Las Palmas III seawater reverse osmosis (RO) desalination plant with a capacity of 36,000 m(3)/d. This system is aimed to control membrane fouling. It consists in the non-dosing of sodium hypochlorite or another biocide to seawater in order to minimize RO membrane biofouling. The pH regulation at 6.5 controls the scaling and the 12.5 ppm dosage of FeCl3 as a coagulant maximizes the coagulation efficiency of colloidal particles and controls the fouling process.