Phase Contrast Microradiography of Mouse Lung Using Synchrotron X-ray: Correlation with Optical Microscopy

被引:6
|
作者
Yong, Hwan Seok [1 ,5 ]
Kang, Eun-Young [1 ]
Kim, Yoon Kyung [1 ]
Woo, Ok Hee [1 ]
Shin, Bong Kyoung [2 ]
Oh, Chil Hwan [3 ]
Je, Jung Ho [4 ]
Han, Heon [5 ]
Seo, Jae Seung [5 ,6 ]
机构
[1] Korea Univ, Guro Hosp, Dept Radiol, Seoul 152703, South Korea
[2] Korea Univ, Guro Hosp, Dept Pathol, Seoul 152703, South Korea
[3] Korea Univ, Guro Hosp, Res Inst Skin Imaging, Seoul 152703, South Korea
[4] Pohang Univ Sci & Technol, Dept Mat Sci & Engn, Pohang, South Korea
[5] Kangwon Natl Univ, Dept Radiol, Coll Med, Chunchon, South Korea
[6] Chung Ang Univ, Coll Med, Dept Radiol, Seoul 156756, South Korea
关键词
Phase contrast microradiography; polychromatic synchrotron X-ray; refraction enhanced imaging; lung; RABBIT LUNGS; INJURY; CT;
D O I
10.3349/ymj.2009.50.3.422
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. Materials and Methods: Normal mice were used for experiments. Some of the mouse lungs were prepared by the lung fixation-inflation method. The resulting sponge-like inflated lung samples were used for microtomography. The remaining mouse lungs were cut into 10 um sections and were used for microradiography and optical microscopic correlation. The experiments on mouse lung samples were per-formed at the 7B2 beamline of the Pohang Light Source in Korea. Results: Phase contrast X-ray microtomography of inflated lung samples showed individual alveolar structure on 3-D reconstruction. Phase contrast microradiographs of thin lung samples showed microstructure of lung, such as alveoli and bronchioles, and were well correlated with optical microscopic images. Conclusions: The results indicate that the phase contrast X-ray microtomography and microradiography using polychromatic synchrotron X-ray is feasible for evaluation of microstructure of the lung.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [41] Refraction-enhanced x-ray imaging of mouse lung using synchrotron radiation source
    Yagi, N
    Suzuki, Y
    Umetani, K
    Kohmura, Y
    Yamasaki, K
    MEDICAL PHYSICS, 1999, 26 (10) : 2190 - 2193
  • [42] Experimental Study of the Method of X-ray Phase-Contrast Microscopy Using a Nanofocusing Lens at KISI-Kurchatov Synchrotron Source
    Folomeshkin, M. S.
    Kohn, V. G.
    Seregin, A. Yu.
    Volkovsky, Yu. A.
    Prosekov, P. A.
    Yunkin, V. A.
    Snigirev, A. A.
    Pisarevsky, Yu. V.
    Blagov, A. E.
    Kovalchuk, M. V.
    CRYSTALLOGRAPHY REPORTS, 2024, 69 (06) : 787 - 793
  • [43] Phase-contrast X-ray microtomography of mouse fetus
    Hoshino, Masato
    Uesugi, Kentaro
    Yagi, Naoto
    BIOLOGY OPEN, 2012, 1 (03): : 269 - 274
  • [44] APPLICATION OF SYNCHROTRON RADIATION TO X-RAY MICROSCOPY
    DUKE, PJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 368 : 21 - 25
  • [45] Studies in synchrotron x-ray microradiography: observation of biprism-type interference
    Lang, AR
    Makepeace, APW
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (10A) : A172 - A178
  • [46] New types of X-ray computed tomography (CT) with synchrotron radiation: Fluorescent X-ray CT and phase-contrast X-ray CT using interferometer
    Takeda, T
    Momose, A
    Yu, QW
    Yuasa, T
    Dilmanian, FA
    Akatsuka, T
    Itai, Y
    CELLULAR AND MOLECULAR BIOLOGY, 2000, 46 (06) : 1077 - 1088
  • [47] Characterization of mouse spinal cord vascular network by means of synchrotron radiation X-ray phase contrast tomography
    Massimi, Lorenzo
    Fratini, Michela
    Bukreeva, Inna
    Brun, Francesco
    Mittone, Alberto
    Campi, Gaetano
    Spano, Raffaele
    Mastrogiacomo, Milena
    de Rosbo, Nicole Kerlero
    Bravin, Alberto
    Uccelli, Antonio
    Cedola, Alessia
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1779 - 1784
  • [48] Diffractive optical elements for differential interference contrast x-ray microscopy
    Di Fabrizio, E
    Cojoc, D
    Cabrini, S
    Kaulich, B
    Susini, J
    Facci, P
    Wilhein, T
    OPTICS EXPRESS, 2003, 11 (19): : 2278 - 2288
  • [49] Synchrotron X-ray phase-contrast imaging of ultrasonic drop atomization
    Prasanna, Anunay
    Biasiori-Poulanges, Luc
    Yu, Ya-Chi
    El-Rabii, Hazem
    Lukic, Bratislav
    Supponen, Outi
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2024, 174
  • [50] PARALLEL BEAM MICRORADIOGRAPHY OF DENTAL HARD TISSUE USING SYNCHROTRON RADIATION AND X-RAY IMAGE MAGNIFICATION
    TAKAGI, S
    CHOW, LC
    BROWN, WE
    DOBBYN, RC
    KURIYAMA, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 222 (1-2): : 256 - 258